6
·
Next to the filters, you
’ll find the diverter valve to change from filtration to spray
nozzle (Spray Gun / Spray Bar Lever).
·
In the spray gun position, water will flow when the trigger is pulled. The spray can be
adjusted by opening clockwise for the Stream Spray or counterclockwise for the O
Mist Spray.
·
Fill the wash tank with water (
see note at the bottom of this page)
and the proper
dilution of soap to just above the spray bar. Using hot water will shorten the amount
of time required to reach the desired temperature. Check drain assembly to insure
that there is no leakage.
·
The Model 5224UW tank dimensions are 52
” x 24” with a 20” overall working depth.
This tank will hold 108 gallons and has a working volume of approximately 86
gallons when the water level is at the midpoint of the spray bar. This liquid volume
does not include the liquid in the pump / filter system. Use this volume for calculating
the amount of detergent you will use.
*Note About Water*
The quality of your water source can have an important effect on the performance of the
ultrasonic equipment. High levels of calcium, magnesium, sulfur and other contaminants
in the water source can have a negative effect on the type of cleaning soap used. High
levels of calcium and/or magnesium (constitutes hard water) can cause the soap to
work less efficiently and less effectively as intended and can also leave a white, flaky
residue on the parts once dried. If this white spotting occurs and is not desired, it will be
necessary to use soft water, drinking water or distilled water, in the machine. The level
of final cleanliness will dictate the water source used in the machine.