7.1.1.3.2 Lock
If set, the user-specified units of measure string (4 character maximum) will be used in place of
the default
.
7.1.1.3.3 Apply Scaling
If set, the user-defined Offset and Gain values will be used to adjust the sensor reading:
Result = (Raw Reading * Gain) + Offset
7.1.1.3.4 Assigned
The Assigned bit will always read as 0.
7.1.1.3.5 Available
The Available bit will always read as 0.
7.1.2 Digital Input Device Byte
For digital input types, the Device Byte field determines the signal types for each of the channel bits.
Digital I/O Device Byte
SIG 2 (ENABLE)
SIG 1 (RESET)
SIG 0 (PULSE)
7 6 5
Description
4 3
Description
2 1 0
Description
0 0 0
N.O. SINK (DRY)
0 0
N.O. SINK (DRY)
0 0 0
N.O. SINK (DRY)
0 0 1
N.C. SINK (DRY)
0 1
N.C. SINK (DRY)
0 0 1
N.C. SINK (DRY)
0 1 0
N.O. SOURCE (WET)
1 0
N.O. SOURCE (WET)
0 1 0
N.O. SOURCE (WET)
0 1 1
N.C. SOURCE (WET)
1 1
N.C. SOURCE (WET)
0 1 1
N.C. SOURCE (WET)
1 0 0
COMPARATOR
(100 mV)
1 0 1
COMPARATOR
(500 mV)
1 1 0
COMPARATOR
(1.0 V)
1 1 1
COMPARATOR
(2.0 V)
7.1.3 Digital Sensor Parameters
There are no Digital Sensor Parameters.