background image

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords 

our customers the latest in technology and engineering.
OMEGA is a trademark of OMEGA ENGINEERING, INC.
© Copyright 2019 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, 

reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the 

prior written consent of OMEGA ENGINEERING, INC.

FOR 

WARRANTY

 RETURNS, please have the  

following information available BEFORE contacting 

OMEGA:
1.   Purchase Order number under which the product 

was PURCHASED,

2.   Model and serial number of the product under 

warranty, and

3.  Repair instructions and/or specific problems  

  relative to the product.

FOR 

NON-WARRANTY

 REPAIRS, consult 

OMEGA for current repair charges. Have 

the following information available BEFORE 

contacting OMEGA:
1.  Purchase Order number to cover the COST  

  of the repair,
2.  Model and serial number of the product, and
3.  Repair instructions and/or specific problems  

  relative to the product.

RETURN REQUESTS/INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. 

BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED 

RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID 

PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return 

package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent 

breakage in transit. 

 

WARRANTY/DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a 

period of 

13 months

 from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month 

grace period to the normal 

one (1) year product warranty

 to cover handling and shipping time. This 

ensures that OMEGA’s customers receive maximum coverage on each product. 
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service 

Department will issue an Authorized Return (AR) number immediately upon phone or written request. 

Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no 

charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, 

including but not limited to mishandling, improper interfacing, operation outside of design limits,  

improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of  

having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; 

or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating 

conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not  

limited to contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However,  

OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for 

any damages that result from the use of its products in accordance with information provided 

by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the 

company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR  

REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF 

TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY 

AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF  

LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of  

OMEGA with respect to this order, whether based on contract, warranty, negligence,  

indemnification, strict liability or otherwise, shall not exceed the purchase price of the  

component upon which liability is based. In no event shall OMEGA be liable for  

consequential, incidental or special damages.

CONDITIONS:  Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic 

Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical 

applications or used on humans. Should any Product(s) be used in or with any nuclear installation or 

activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility 

as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify 

OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the 

Product(s) in such a manner.

Содержание SP-005

Страница 1: ...1 P a g e TM User sGuide Shop online at omega com e mail info omega com For latest product manuals www omegamanual info SP 005 Thermocouple and RTD Smart Probe...

Страница 2: ...nly Customer Service 1 800 622 2378 USA Canada only Engineering Service 1 800 872 9436 USA Canada only U S A Headquarters Tel 203 359 1660 e mail info omega com Fax 203 359 7700 The information contai...

Страница 3: ...Calibrate 14 5 1 2 3 Sensor Writeable 14 5 1 2 4 Smart Sensor 14 5 1 3 Thermocouple Configuration 14 5 1 3 1 Sensor Type Range 14 5 1 3 2 Apply Scaling 14 5 1 3 3 Lock 15 5 1 3 4 Assigned 15 5 1 3 5...

Страница 4: ...Writeable 19 5 3 1 6 Smart Sensor 19 5 3 2 DIO Input Configuration 19 5 3 2 1 Lock 19 5 3 2 2 Apply Scaling 19 5 3 2 3 Assigned 19 5 3 2 4 Available 19 5 3 3 DIO Device Configuration 20 5 3 4 DIO IPSO...

Страница 5: ...vice as it contains important information relating to safety and EMC Failure to follow all the safety precautions may result in injury and or damage to your equipment The following labels identify inf...

Страница 6: ...to 2 thermocouple inputs or a single 2 3 or 4 wire RTD input The Layer N SP 005 features 2 configurable digital I O pins These can be used for a myriad of applications including driving relays physic...

Страница 7: ...to the SP 005 If you are connecting wire directly to the SP 005 view the wiring diagrams provided below Pin Name Function Pin 1 DIO 0 Discrete I O Signal 0 Pin 2 INTR Interrupt Signal Pin 3 SCL I2C Cl...

Страница 8: ...ot automatically detect your device follow these instructions to manually connect it Step 1 Click on the icon located on the top left of the SYNC interface Step 2 Proceed through the Add Device Wizard...

Страница 9: ...checking correctness of character by adding an extra bit to the character and setting the value based on all the other bits in the character StopBits The number of bits used to indicate the end of the...

Страница 10: ...be performed as described below Step 1 Ensure your thermocouple has been configured in the previous section and click Calibration beneath the input interface Step 2 Insert the probe into 0 C 32 F refe...

Страница 11: ...wn Step 2 Click the input you wish to configure and select your RTD type from the Device Range Type dropdown Step 3 Click the Wire dropdown and choose your wiring configuration 4 5 Setting Alarms Alar...

Страница 12: ...he Output Configuration Tab in SYNC and click on the icon located to the right of the available outputs Clicking the icon will open Define ON OFF Control dialog box as seen below Choose the input with...

Страница 13: ...nformation is provided in sensor specific IPSO object descriptions which include extended measurement type precision and tracking of minimum maximum readings Each enumerated Sensor has a Descriptor Ba...

Страница 14: ...s set the sensor value may be overwritten with a preset value This capability is useful in sensors such as up down counters where a preset or possibly a zero value must be written to the sensor value...

Страница 15: ...PSO object type information The Range information is Thermocouple Type dependent Offset Name Value Description 0x00 Sensor Type 3303 Temperature oC 0x02 Precision 1 Provides reading of xxx x 0x04 Sens...

Страница 16: ...The RTD interface provides a measurement of Temperature in C Sensor Type SI Derived Units Measurement 0x21 C RTD Temperature 5 2 2 RTD Input Data Type Format The SP 005 supports extended configuration...

Страница 17: ...will be used to adjust the sensor reading Result Raw Reading Gain Offset 5 2 3 3 Lock If set the user specified units of measure string 4 character maximum will be used in place of the default units...

Страница 18: ...the IPSO min max values Sensor Trigger Function 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 Reset Min Max 15 14 13 12 11 10 9 8 0 0 0 0 0 0 0 0 5 3 Digital Input Output Interface The DIO Interface provides 2 digita...

Страница 19: ...t or possibly a zero value must be written to the sensor value 5 3 1 6 Smart Sensor Refer to the Smart Sensor Device Interface documentation 5 3 2 DIO Input Configuration DIO Input Configuration 7 6 5...

Страница 20: ...PSO object type information The SP 010 DIO IPSO definition is at base address 0x08a8 Offset Name Value Description 0x00 Sensor Type 3349 Bit Mapped Digital 0x02 Precision 0 Provides reading of xxx 0x0...

Страница 21: ...he output LOW When the state of the DIO input signal is to be read the processor applies 3 0 VDC to the Input Bias signal and reads the level detected at the Input Sense If the output is inactive an e...

Страница 22: ...10 Hz PWM signal has constant 10 Hertz frequency 100 msec repetition rate with 0 100 duty cycle 2 1 Hz PWM signal has constant 1 Hertz frequency 1 second repetition rate with 0 100 duty cycle 3 0 1 H...

Страница 23: ...Compatible with OEG SYNC configuration software Layer N Cloud and Modbus Networks THERMOCOUPLE ACCURACY TABLE Type Range Accuracy J 210 C to 1200 C 0 4 C K 160 C to 1372 C 0 4 C T 190 C to 400 C 0 4 C...

Страница 24: ...A if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to m...

Страница 25: ...s M U Turbine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U...

Отзывы: