14 |
P a g e
5.1.2
Thermocouple Input Data Type/Format
The SP-005 supports extended configuration and provides factory calibration. All data values are returned as 32-bit
floating point values.
Thermocouple Input Data Type
7
6
5
4
3
2
1
0
Smart
Sensor
Sensor
Writeable
Factory
Calibrate
Reserved
Data Type
0
0
?
0
0x06 == FLOAT
5.1.2.1
Data Type
The 4-bit Data Type field determines the type of data of the specific sensor.
5.1.2.2
Factory Calibrate
The Factory Calibrate bit is used during factory calibration. If set, the factory calibration attributes are applied to the
sensor reading before the sensor scaling. If clear, not factory calibration attributes are applied. If the sensor does not
support factory calibration the Factory Calibrate bit is ignored and will always read as 0.
5.1.2.3
Sensor Writeable
If the Sensor Writeable bit is set the sensor value may be overwritten with a preset value. This capability is useful in
sensors such as up/down counters, where a preset, or possibly a zero value must be written to the sensor value.
5.1.2.4
Smart Sensor
Refer to the
Smart Sensor Device Interface
documentation.
5.1.3
Thermocouple Configuration
Thermocouple Configuration
7
6
5
4
3
2
1
0
Available
Assigned
Apply
Scaling
Lock
Sensor Type (Range)
0
*
?
?
See Below
5.1.3.1
Sensor Type / Range
Sensor Type
Sensor Input Type (Range)
Measurement Type
0x00
Type J
0x20
Temperature (°C)
0x01
Type K
0x20
Temperature (°C)
0x02
Type T
0x20
Temperature (°C)
0x03
Type E
0x20
Temperature (°C)
0x04
Type N
0x20
Temperature (°C)
0x05
Reserved
0x20
Temperature (°C)
0x06
Type R
0x20
Temperature (°C)
0x07
Type S
0x20
Temperature (°C)
0x08
Type B
0x20
Temperature (°C)
0x09
Type C
0x20
Temperature (°C)
5.1.3.2
Apply Scaling
For more information on Gain and Offset, refer to the Smart Sensor Manual. If set, the user defined Offset and Gain
values will be used to adjust the sensor reading:
Result = (Raw Reading * Gain) + Offset