“HOLD” key to stop reading, all values are frozen, press 
“HOLD” key again to restart reading. 

5. “MAX/MIN” Button 

Press  “MIN/MAX”  key  to  enter  the  MIN/MAX  re-

cording  mode  and  REC  shows  on  the  display.  The 
beeper emits a tone when a new minimum or maximum 
measurement is recorded. Press “MIN/MAX” key again 
to cycle through the current readings: 

MAX: The highest measurement recorded. 
MIN: The lowest measurement recorded. 
MAX-MIN: The difference of the highest and the  low-

est measurement. 

AVG: The average values of the measurements. 

Press “MIN/MAX” key over two seconds to exit the 

function.  In  this  mode,  press  “HOLD”  key  to  stop  re-
cording, all values are frozen, press “HOLD” key again 
to restart recording. In this mode, the APO function and 
other  keys  are  disabled,  excluding  “HOLD”  and 
Back-light keys. Press and hold down the “MAX/MIN” 
key  for  more  than  2  seconds  to  exit  the  MAX/MIN 
function. 

6. “HOLD” Button 

Press the “HOLD” key to enter the data hold mode, the 
“HOLD”  annunciator  is  displayed  at  the  center-left  of 
display. When data hold mode is selected, the meter held 
the present readings and stops all further measurements. 
Press the “HOLD” key again to cancel data hold mode, 
causing meter to resume taking measurements. 

7. “WB/DP” Button

 

In  the  NTC  data  Mode,  the  Meter  displays  ambient 

temperature  when  first  turned  on.  To  display  wet 
bulb (WB) temperature, press “WB/DP” key once. Press 
the  “WB/DP”  again  to  switch  to  dew  point (DP)  tem-
perature. Press “WB/DP” a third time returns the Meter 
to ambient temperature. 

8. “K/NTC/K-DP” Button

 

Press  the  “K/NTC/K-DP”  key,  the  meter  can  cycle 

through “K-TYPE”, “NTC”, “K-DP”. 

  K-DP  =  K-TYPE  temperature  minutes  Dew  point 

temperature. 

9. “SAVE” Button

 

The  save  function  stores  the  %RH,  K-TYPE,  NTC, 

Wet  bulb,  Dew  point  data  in  a  nonvolatile  memory. 
Press the “SAVE” key to save the current data, the word 
SAVE  is  displayed  to  indicate  the  data  are  saved.  The 
build in memory can store up to 256 data. 

10. “READ”, “ ”, “ ” Button

 

To  recall  the  readings  from  memory,  press  “READ” 

key. To check the memorized data just to press “ ” or 
“ ”  until  the  desired  memorized  data  is  displayed.  To 
return the meter to normal operation, press “READ” key 
again. 

 CLR SAVE DATA:

 

Pressing  the  “ ”  key  for  more  than  5  seconds  to 

clears all the saved data in memory. And lower display 

show “Clr” about 2 second. 

11. WIRELESS MODE:

 

(820W)

 

Press the “ ” key for more than two seconds to start 

wireless  function. Press  the  “ ”  key  again  for  another 
two  seconds  to  stop  wireless  function.  The  wireless 
mode  will  shut  down  if  there  is  no  wireless  signal  for 
two minutes. 

To SET CH/ID to 00,00, press the “ ” key and “

” 

power key for more than 6 seconds with the meter pow-
ered down. The meter will set channel and ID to 00,00 
status.  The  second  display  will  show  00,  which  means 
that the channel and ID has been set to 00. 

To check the channel and ID of the meter:

 

When  the  meter  is  off,  press  “°C/°F”  key  and  “

” 

for  5  seconds,  LCD’s  main  display  will  show  channel 
number, the second display will show ID number. 

 

OPERATOR MAINTENANCE 

WARNING 

To avoid possible electrical shock, disconnect the 

thermocouple connectors from the thermometer before 

removing the cover.

 

Battery Replacement 

1.  Power  is  supplied  by  4pcs  1.5V  (SIZE  AAA)  UM-4 

R03. 

2.  The  “

”  appears  on  the  LCD  display  when  replace-

ment  is  needed.  To  replace  battery  remove  screw  from 
back of meter and lift off the battery cover. 

3. Remove the battery from battery contacts and replace. 
4. When not use for long time remove battery. 
5. Don’t keep in place with high Temp, or high humidity. 
 

Cleaning 

Periodically wipe the case with a damp cloth and deter-

gent, do not use abrasives or solvents. 
 
 

*Software operation manual is on the software disk. 

 
 
 
 
 
 
 
 

 

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in
materials and workmanship for a period of

from date of pur-

chase. OMEGA’s WARRANTY adds an additional one (1) month grace
period to the normal

to cover handling and

shipping time. This ensures that OMEGA’s customers receive maximum
coverage on each  product.

If the unit malfunctions, it must be returned to the factory for evaluation.
OMEGA’s Customer Service Department will issue an Authorized Return
(AR) number immediately upon phone or written request. Upon examination
by OMEGA, if the unit is found to be defective, it will be repaired or replaced
at no charge. OMEGA’s WARRANTY does not apply to defects resulting
from any action of the purchaser, including but not limited to mishandling,
improper interfacing, operation outside of design limits, improper repair, or
unauthorized modification. This WARRANTY is VOID if the unit shows
evidence of having been tampered with or shows evidence of having been
damaged as a result of excessive corrosion; or current, heat, moisture or
vibration; improper specification; misapplication; misuse or other operating
conditions outside of OMEGA’s control. Components which wear is not
warranted, include but are not limited to contact points, fuses, and triacs.

CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor
shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used
in or with any nuclear installation or activity; or (2) in medical applications or
used on humans. Should any Product(s) be used in or with any nuclear
installation or activity, medical application, used on humans, or misused in
any way, OMEGA assumes no responsibility as set forth in our basic
WARRANTY / DISCLAIMER language, and, additionally, purchaser will
indemnify OMEGA and hold OMEGA harmless from any liability or damage
whatsoever arising out of the use of the Product(s) in such a manner.

Direct all warranty and repair requests / inquiries to the OMEGA Customer
Service Department. BEFORE RETURNING ANY PRODUCT(S) TO
OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR)
NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN
ORDER TO AVOID PROCESSING DELAYS). The assigned AR number

should then be marked on the outside of the return package and on any
correspondence.
The purchaser is responsible for shipping charges, freight, insurance and
proper packaging to prevent breakage in transit.
FOR

RETURNS,

please have the following
information available BEFORE
contacting OMEGA:
1. Purchase  Order number under

which the product was
PURCHASED,

2. Model  and serial number of the

product under warranty, and

3. Repair  instructions and/or specific

problems relative to the product.

FOR
REPAIRS, consult OMEGA for
current repair charges. Have the
following information available
BEFORE contacting OMEGA:
1. Purchase  Order number to cover

the COST  of the repair,

2. Model  and serial number of the

product, and

3. Repair  instructions and/or specific

problems relative to the product.

OMEGA’s policy is to make running changes, not model changes, whenever
an improvement is possible. This affords our customers the latest in tech-
nology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2009 OMEGA ENGINEERING, INC. All rights reserved. This
document may not be copied, photocopied, reproduced, translated, or
reduced to any electronic medium or machine-readable form, in whole or in
part, without the prior written consent of OMEGA ENGINEERING, INC.

Where Do I Find Everything I Need for

Process Measurement and Control?

OMEGA…Of Course!

Shop online at omega.com

TEMPERATURE

Thermocouple, RTD & Thermistor Probes,

Connectors, Panels & Assemblies

Wire: Thermocouple, RTD & Thermistor

Calibrators & Ice Point References

Recorders, Controllers & Process Monitors

Infrared Pyrometers

PRESSURE, STRAIN AND FORCE

Transducers & Strain Gages

Load Cells & Pressure Gages

Displacement Transducers

Instrumentation & Accessories

FLOW/LEVEL

Rotameters, Gas Mass Flowmeters & Flow Computers

Air Velocity Indicators

Turbine/Paddlewheel Systems

Totalizers & Batch Controllers

pH/CONDUCTIVITY

pH Electrodes, Testers & Accessories

Benchtop/Laboratory Meters

Controllers, Calibrators, Simulators & Pumps

Industrial pH & Conductivity Equipment

DATA ACQUISITION

Data Acquisition & Engineering Software

Communications-Based Acquisition Systems

Plug-in Cards for Apple, IBM & Compatibles

Datalogging Systems

Recorders, Printers & Plotters

HEATERS

Heating Cable

Cartridge & Strip Heaters

Immersion & Band Heaters

Flexible Heaters

Laboratory Heaters

ENVIRONMENTAL
MONITORING AND CONTROL

Metering & Control Instrumentation

Refractometers

Pumps & Tubing

Air, Soil & Water Monitors

Industrial Water & Wastewater Treatment

pH, Conductivity & Dissolved Oxygen Instruments

Servicing Europe:

Benelux:

Managed by the United Kingdom Office

Toll-Free: 0800 099 3344

TEL: +31 20 347 21 21

FAX: +31 20 643 46 43

e-mail: [email protected]

Czech

Frystatska 184, 733 01 Karviná, Czech Republic

Republic:

Toll-Free: 0800-1-66342

TEL: +420-59-6311899

FAX: +420-59-6311114

e-mail: [email protected]

France:

Managed by the United Kingdom Office

Toll-Free: 0800 466 342

TEL: +33 (0) 161 37 29 00

FAX: +33 (0) 130 57 54 27

e-mail: [email protected]

Germany/

Daimlerstrasse 26, D-75392 Deckenpfronn, Germany

Austria:

Tel:+ 49 (0)7056 9398-0

FAX: +49 (0)7056 9398-29

Toll Free in Germany: 0800 639 7678  e-mail: [email protected]

United

OMEGA Engineering Ltd. 

Kingdom:

One Omega Drive

ISO 9001 Certified

River Bend Technology Centre, Northbank

Irlam, Manchester M44 5BD England

Toll-Free: 0800-488-488

TEL: +44 (0)161 777-6611

FAX: +44 (0)161 777-6622

e-mail: [email protected]

Servicing North America:

U.S.A.:

OMEGA Engineering, Inc. 

ISO 9001 Certified

One Omega Drive, P.O. Box 4047

Stamford, CT 06907-0047 USA

Toll-Free: 1-800-826-6342

TEL: (203) 359-1660

FAX: (203) 359-7700

e-mail: [email protected]

Canada:

976 Bergar, Laval (Quebec), Canada H7L 5A1

Toll-Free: 1-800-826-6342

TEL: (514) 856-6928

FAX: (514) 856-6886

e-mail: [email protected]

For immediate technical or application assistance:

U.S.A. and 

Sales Service: 1-800-826-6342/1-800-TC-OMEGA

®

Canada:

Customer Service: 1-800-622-2378 1-800-622-BEST

®

Engineering Service: 1-800-872-9436/1-800-USA-WHEN

®

Mexico:

En Español: 001 (203) 359-7803 FAX: (001) 203-359-7807

[email protected]

e-mail: [email protected]

OMEGAnet

®

On-Line Service 

Internet e-mail

omega.com 

[email protected]

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI

regulations that apply. OMEGA is constantly pursuing certification of its

products to the European New Approach Directives. OMEGA will add the CE

mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but

OMEGA Engineering, Inc. accepts no liability for any errors it contains, and

reserves the right to alter specifications without notice.

WARNING: 

These products are not designed for use in, and should not be

used for, human applications.