background image

INTRODUCTION

 

Thank you for purchasing PHH-SD1 pH Meter with Datalogging SD Card. Please read this 
user’s manual carefully and thoroughly before using the instrument. 
 
The PHH-SD1 is a general-purpose handheld instrument suitable for measuring the pH and 
oxidation-reduction potential (ORP) of a solution. Using optional probes with a BNC connector, 
the meter can measure pH from 0 to 14 and ORP from -1999 mV to +1999 mV. The meter also 
accepts an optional automatic temperature compensation (ATC) probe that configures the pH 
electrode to measure solutions whose temperature is between 32 and 150

o

F (0 and 65

o

C). For 

measuring the pH of solutions at temperatures between 32 and 212

o

F (0 and 100

o

C), the 

temperature compensation can be set manually. pH electrodes must be calibrated for pH 4, pH 7 
and pH 10 using buffer solutions. 
 
Among the applications and environments suitable for the PHH-SD1 are water conditioning, 
wastewater monitoring, beverage production, aquaculture (fish farming), aquariums, pulp and 
paper processing, electroplating, and photography. 
 
The PHH-SD1 has the performance and features needed to satisfy the most demanding aspects of 
the above applications. A front-panel pushbutton enables rapid switching between the two 
measurement modes. Measurement accuracies are ± (0.02 pH units + 2 digits) for pH readings 
and ± (0.5% of the r 2 digits) for ORP readings. 
 
Because it is microprocessor-based, the PHH-SD1 can make full use of the portability, reliability 
and large storage capacities that SD memory cards offer. Measurements can be made 
automatically at any sampling rate between one second and nine hours. After time-stamping and 
storing the measurements on an SD card plugged into the instrument (a process called 
datalogging), the user can remove the card and plug it into to a laptop or desktop computer either 
directly or via a USB card reader. The data logs are stored on the card as files with the .xls 
extension, which can be opened by Microsoft’s Excel application. 
 
The PHH-SD1 has a backlit 2-1/2 inch diagonal display and is powered by six AA Alkaline 
batteries or an optional 9-VDC AC adapter. 
 

KEY FEATURES

 

 

 

Measures pH and ORP using optional electrodes 

 

Measured parameter can be changed by pressing front-panel button 

 

Optional ATC temperature probe automatically calibrates pH electrode to pH 4, pH  and 
pH 10 

 

Displays maximum and minimum readings 

 

Performs real-time automatic datalogging at sampling time settable from 1 second to 9 
hours 

 

Also supports manual logging and changing of card storage location 

 

Outputs Excel-compatible data logs 

 

Accepts SD memory cards of up to 16 GB capacity 

 

Big (2.5-inch diagonal) front-panel green backlit LCD is easy to read 

 

Auto power off function 

 

Powered by six AA batteries or optional 9V AC/DC adapter 

 
 

1

Содержание PHH-SD1

Страница 1: ...PHH SD1 pH Meter With Data Logging SD Card e mail info omega com For latest product manuals www omegamanual info Shop online at omega com User sGuide NORWALK CT TM...

Страница 2: ...pecifications without notice omega com info omega com Servicing North America U S A Headquarters Omega Engineering Inc Toll Free 1 800 826 6342 USA Canada only Customer Service 1 800 622 2378 USA Cana...

Страница 3: ...es 1 Operating Instructions 2 What s in the case 2 Setup 3 Calibrating the pH electrode 5 Normal operation 6 Holding and storing measurements 7 Automatic vs manual datalogging 7 Transferring data from...

Страница 4: ...2 pH units 2 digits for pH readings and 0 5 of the reading 2 digits for ORP readings Because it is microprocessor based the PHH SD1 can make full use of the portability reliability and large storage c...

Страница 5: ...the front back top bottom and right side of the PHH SD1 Familiarize yourself with the positions and functions of these controls indicators and connectors before moving on to the setup procedure 1 The...

Страница 6: ...he screen will revert to the normal display To return to the setup sequence press and hold the LOGGER SET button again To move ahead to the next field in the sequence or to the next parameter press th...

Страница 7: ...ss the button until the desired setting yES or no is displayed and then press the REC ENTER button to store the selection 8 Choose a decimal point or comma to represent the decimal division between in...

Страница 8: ...d 2 4 pH buffer solution 1 Insert the plug of the pH electrode into the BNC socket at the top of the meter callout 1 14 of Fig 1 2 Power on the meter by pressing the POWER button 3 Using the procedure...

Страница 9: ...7 pH 4 and pH 10 Normal operation The PHH SD1 can measure either the pH or the oxidation reduction potential ORP of a solution 1 To select the type of measurement press the button which has the word...

Страница 10: ...e TIME button Doing so causes both values to appear briefly at the lower left of the display Holding and storing measurements 4 To hold a measured value of pH or ORP press the HOLD ESC button during t...

Страница 11: ...his mode the instrument is storing measurements and their time stamps on the SD card In manual datalogging mode however measurements are being stored continuously with a sampling time of zero and thei...

Страница 12: ...3 Typical Excel data only screen 4 Typical Excel graphics only screen 5 Typical Excel mixed data graphics screen 9...

Страница 13: ...normal operation with backlight off and SD card not saving data 37 mADC with backlight on and card saving data 49 mADC with backlight on and card saving data Dimensions 6 97 x 2 68 x 1 77 inches 177 x...

Страница 14: ...ecification misapplication misuse or other operating conditions outside of OMEGA s control Components in which wear is not warranted include but are not limited to contact points fuses and triacs OMEG...

Страница 15: ...s M U Turbine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U...

Отзывы: