background image

23

Technical Information

Protection Functions 

Overcurrent  Protection

Overheating Prevention Protection 

If  the  evaporator  tube  temperature  overheats,  the  outdoor  fan  stops  operation.  When  the  tube  temperature  resumes 
normally, the outdoor fan resumes operation. 

Noise Silencing Protection 

If the unit is turned off by pressing ON/OFF button or during mode switchover, the 4-way valve stops after 2 minutes. 

(4) Fan mode 
In fan mode, indoor fan operates at setting speed while the compressor, outdoor fan, 4-way valve and electric heating tube 
stop operation.   
In this mode, temperature setting range is 16 30 . The indoor unit displays operation icon and setting temperature. 
(5) Auto Mode 
In AUTO mode, the unit will automatically select its operation mode (cooling, heating or fan) with the change of ambient 
temperature. The indoor unit displays the operation icon, operation mode icon and setting temperature. There is 30-second 
delay protection for mode switchover. Protection functions are the same as those in any other modes. 

3 Other Control  
(1)Timer function 
General timer and clock timer functions are compatible by equipping different functions of remote controller.   

 General Timer 

Timer ON can be set at unit OFF. If ON time setting is reached, the unit will start to operate according to previous setting 
status. Time setting range is 0.5-24hr in 30-minute increments. 
Timer OFF can be set at unit ON. If OFF time setting is reached, the unit will stop operation. Time setting range is 0.5-24hr 
in 30-minute increments.   

 Clock Timer 

Timer ON 
If timer ON is set during operation of the unit, the unit will continue to operate. If timer ON is set at unit OFF, upon ON time 
reaches the unit will start to operate according to previous setting status. 
Timer OFF 
If timer OFF is set at unit OFF, the system will keep standby status. If timer OFF is set at unit ON, upon OFF time reaches 
the unit will stop operation.   
Timer Change 
Although timer has been set, the unit still can be turned on/off by pressing ON/OFF button of remote controller. You can 
also set the timer once again, and then the unit will operate according to the last setting.     
If timer ON and timer OFF are set at the same time during operation of the unit, the unit will keep operating at current status 
till OFF time reaches. 
If timer ON and timer OFF are set at the same time at unit OFF, the unit will keep stop till ON time reaches.   
In the future’s every day, the system will operate according to presetting mode till OFF time reaches and stop operation till 
ON time reaches. If ON time and OFF time are the same, timer OFF has the priority.   
(2) Auto Button 
If this button is pressed, the unit will operate in AUTO mode and indoor fan will operate at auto speed; meanwhile, the 
swing motor operates. Press this button again to turn off the unit. 
(3) Buzzer 
Upon energization or availably operating the unit or remote controller, the buzzer will give out a beep. 
(4) Sleep Function 

In this mode, the unit will select the suitable sleep curve to operate according to the setting temperature. 

(5)Turbo Function 
This function can be set in cooling or heating mode to quickly cool or heat the room.   
(6) X-Fan Function 
This function can be set in COOL or DRY mode. 
(7) Automatic Control of Fan Speed 
In this mode, the indoor fan will automatically select high, medium or low speed with the change of ambient temperature. 
(8)Up & Down Swing 
After energization, up & down swing motor will firstly let the horizontal louver anticlockwise rotate to position 0 to close air 
outlet.                  

 

  This protection is the same as that in cooling mode (But indoor fan will blow residual heat).

Содержание OTEC IEWQ Series

Страница 1: ...IEWQ ICHQ Series High Wall Inverter Technical Manual...

Страница 2: ...ling and Heating Data Sheet in Rated Frequency 5 3 Outline Dimension Diagram 6 3 1 Indoor Unit 6 3 2 Outdoor Unit 7 4 Refrigerant System Diagram 8 5 Electrical Part 9 5 1 Wiring Diagram 9 5 2 PCB Prin...

Страница 3: ...1 Technical Information 1 Summary Part Technical Information Indoor Unit Outdoor Unit IEWQ036J3A RWI100 ICHQ036J3A RLH100 Remote Controller...

Страница 4: ...unit IEWQ036J3A RWI100 Indoor Unit Product Code CB434N14900 CB432N22800 Fan Type Cross flow Diameter Length DXL mm 108X522 7 Fan Motor Cooling Speed SH H MH M ML L SL r min 1550 1300 1200 1100 1000 95...

Страница 5: ...W mm 994X57 1X748 Fan Motor Speed rpm 880 Output of Fan Motor W 90 Fan Motor RLA A 0 65 Fan Motor Capacitor F Air Flow Volume of Outdoor Unit m3 h 4000 Fan Type Axial flow Fan Diameter mm 550 Defrosti...

Страница 6: ...7 5m Conditions Indoor DB20 C WB15 C Outdoor DB7 C WB6 C Indoor air flow High Pipe length 7 5m Conditions Indoor DB20 C WB15 C Outdoor DB7 C WB6 C Indoor air flow High Pipe length 5m Cooling Heating...

Страница 7: ...t Inlet and outlet pipe temperature of heat exchanger Fan speed of indoor unit Fan speed of outdoor unit Compressor frequency Hz Indoor Outdoor P MPa T1 C T2 C 27 19 35 24 36K 0 9 to 1 2 12 to 14 43 t...

Страница 8: ...6 Technical Information 3 Outline Dimension Diagram 3 1 Indoor Unit Model W H D 36K Unit mm W D 295 90 40 350 254 746 70 70 H 28K 90 150 54 168 5 462 159 5 55 55 54 1350 326 253...

Страница 9: ...7 Technical Information 3 2 Outdoor Unit Unit mm 1003 790 395 610 920 370 427...

Страница 10: ...ion Liquid pipe 1 4 6mm Gas pipe 5 8 16mm Indoor unit Outdoor unit COOLING HEATING 4 Way valve Discharge Suction Heat exchanger evaporator Heat exchanger condenser Valve Valve Liquid pipe side Gas pip...

Страница 11: ...gle of horizontal lover for this model 60000700130505 3OHDVH GRQ W WRXFK DQ HOHFWURQLF FRPSRQHQW RU WHUPLQDO ZKHQ WKH PDFKLQH LV UXQQLQJ VWRSSLQJ RU KDV EHHQ SRZHUHG RII IRU OHVV WKDQ PLQXWHV WR SUHYH...

Страница 12: ...RU KDV EHHQ SRZHUHG RII IRU OHVV WKDQ PLQXWHV WR SUHYHQW WKH ULVN RI HOHFWULF VKRFN 51 1 20 11 5 1 B 1 1 8 3 1 1 1 8 7 1 225 81 7 5 1 1 8 2 7 50 1 0 1 7 32 5 1 7 6 1625 203 9 8 35 17 5 8 7 2 5 3 1 1 0...

Страница 13: ...ay used for controlling wire 6 Auto key 7 up down swing interface 8 WIFI 9 Interface of ambient temperature sensor 10 Interface of tube temperature sensor 11 Display board 12 Interface of communicatio...

Страница 14: ...re cooling temperature sensor 7 Terminal of low pressure protection 12 Terminal of live wire 3 Terminal of electronic expansion valve 8 Terminal of outdoor fan 13 Terminal of communication 4 Terminal...

Страница 15: ...oller 16 30 61 86 F Fan speed auto low speed low medium speed medium speed medium high speed high speed 3 FAN button This button is used for setting Fan Speed in the sequence that goes from AUTO to th...

Страница 16: ...sequence stated above Press this button can select left right swing angle Fan blow angle can be selected circularly as below button no display stops at current position 6 7 main unit setting temperatu...

Страница 17: ...use remote controller to cancel it temperature or low temperature in order to avoid detecting inaccurate the remote controller near the object of high When I FEEL function is turned on the remote cont...

Страница 18: ...CLOCK buttons simultaneously to start up or turn off energy saving function When energy saving function is startedup SE will be shown on remote controller and air conditioner will adjust the set tempe...

Страница 19: ...ons simultaneously again to exit 8 heating function heating function has been set under Replacement of batteries in remote controller THREE TIMERS TWO TIMERS TIMER CANCELLATION NOTE 1 Press the back s...

Страница 20: ...re setting range is 16 30 and the indoor unit displays operation icon cooling icon and set temperature Protection Functions Antifreezing protection If the system is under antifreezing protection the c...

Страница 21: ...rotection is detected the compressor and the outdoor fan will stop operation and the indoor fan will operate at low speed When the antifreezing protection is eliminated and the compressor has been sto...

Страница 22: ...rate according to previous setting status Timer OFF If timer OFF is set at unit OFF the system will keep standby status If timer OFF is set at unit ON upon OFF time reaches the unit will stop operatio...

Страница 23: ...erature display returns some models if set temperature display is set by the remote controller present set temperature will be displayed 10 Locked protection to PG motor 9 Display When starting the fa...

Страница 24: ...8 32 Ambient temperature Fahrenheit display temperature o F Fahrenheit o F Celsius o C Fahrenheit display temperature o F Fahrenheit o F Celsius o C Fahrenheit display temperature o F Fahrenheit o F...

Страница 25: ...steps A Cut the pip Confirm the pipe length according to the distance of indoor unit and outdoor unit Cut the required pipe with pipe cutter B Remove the burrs Remove the burrs with shaper and prevent...

Страница 26: ...0 63 72 2 439 111 0 737 5 63 46 34 10 2 73 2 358 112 0 717 4 60 23 35 9 779 74 2 28 113 0 697 3 57 18 36 9 382 75 2 206 114 0 678 2 54 31 37 9 003 76 2 133 115 0 66 1 51 59 38 8 642 77 2 064 116 0 642...

Страница 27: ...4 61 34 13 59 73 3 144 112 0 956 4 80 31 35 13 04 74 3 04 113 0 93 3 76 24 36 12 51 75 2 94 114 0 904 2 72 41 37 12 76 2 844 115 0 88 1 68 79 38 11 52 77 2 752 116 0 856 0 65 37 39 11 06 78 2 663 117...

Страница 28: ...2 101 3 22 15 362 9 24 51 41 63 10 93 102 3 13 14 342 8 25 49 19 64 10 54 103 3 04 13 323 9 26 47 08 65 10 18 104 2 96 12 306 2 27 45 07 66 9 83 105 2 87 11 289 6 28 43 16 67 9 49 106 2 79 10 274 29 4...

Страница 29: ...OMEGA IEWQ HQ High Wall Inverter Technical Manual info otecomega com www otecomega com IEWQ CHQ I3A TM1R0622 info otecomega com www otecomega com...

Отзывы: