Technical Information

Note:

● Press this button continuously more than 2s, the main unit will swing back and forth from left to right, and then loosen 

    the button,the unit will stop swinging and 

   present position of guide louver will be kept immediately

.

● Under swing left and right mode, when the status is switched from off to      , if    press this button again 2s later,

      status will switch to off status directly; if press 

   this button again within 2s, the change of swing status will also depend on 

   the circulation sequence stated above.

Press this button can select up & down swing angle. Fan blow angle can be selected circularly as below:

● When selecting "     ", air conditioner is blowing fan automatically. Horizontal 

   louver will automatically swing up & down at

maximum angle.

● When selecting "   

ǃ

    

ǃ

    

ǃ

   

ǃ

  ", air conditioner is blowing fan at fixed 

   position. Horizontal louver will stop at the fixed

 position.

● When selecting "     

ǃ

   

ǃ

   ", air conditioner is blowing fan at fixed angle. 

   Horizontal louver will send air at the fixed angle.

● Hold "    " button above 2s to set your required swing angle. When reaching your   required angle, release the button.

Note:

● "    

ǃ

   

ǃ

   " may not be available. When air conditioner receives this signal, the 

   air conditioner will blow fan automatically

.

● Press this button continuously more than 2s, the main unit will swing back and forth from up to down, and then loosen 

    the button, the unit will stop swinging and    present position of guide louver will be kept immediately. 

● Under swing up and down mode, when the status is switched from off to     , if  press this button again 2s later, 

      status will switch to off status directly; if press 

no display

(horizontal louvers stops

at current position)

 button

   this button again within 2s, the change of swing status will also depend on the 

   circulation sequence stated above.

Press this button can select left & right swing angle. Fan blow angle can be selected circularly as below:

 button

no display

(stops at current position)

6.

7.

main unit setting temperature will increase 1 , two hours, setting temperature increa- sed 2

 setting temperature; In Heat mode: sleep status after run for one hour, the setting temperature will decrease 1 , two hours, 

setting temperature will decrease 2 , then the unit will run at this setting temperature.

●  Sleep 2 is sleep mode 2, that is air conditioner will run according to the presetting a group of sleep temperature curve.
●  Sleep 3-the sleep curve setting under S leep mode by DIY; 

(1)Under Sleep 3 mode, press “Turbo” button for a long time, remote controller enters into user individuation sleep 

setting status, at this time, the time of remote controller will display “1hour”, the setting temperature  “88” will display

 the corresponding temp- erature of last setting sleep curve and blink (The first entering will display according to

the initial curve setting value of original factory);

(2)Adjust "▲" and "    " button, could change the corresponding setting temperature, after adjusted, press “Turbo” button 

 for confirmation;

(3) At this time, 1hour will be automatically increased at the timer postion on the remote

 or "8hours"), the place of setting temperature "88" will display the corresponding temperature of last setting sleep curve and blink;

(4) Repeat the above step (2)~(3) operation, until 8 hours temperature setting finished, sleep,curve setting finished, at this time,

 the remote controller will resume the original timer display; temperature display will resume to original setting temperature.

8.SLEEP button

8

● Press this button, can select Sleep 1 (      ), Sleep 2 (      ), Sleep 3 (      ) and cancel the Sleep, circulate between these,

 after electrified, Sleep Cancel is defaulted.

 after run for one hour, the 

Sleep 1 is Sleep mode 1, in Cool modes; sleep status

, then the unit will run at this

 

control, (that are "2hours" or "3hours"

Содержание OTEC IEWQ Series

Страница 1: ...IEWQ ICHQ Series High Wall Inverter Technical Manual...

Страница 2: ...ling and Heating Data Sheet in Rated Frequency 5 3 Outline Dimension Diagram 6 3 1 Indoor Unit 6 3 2 Outdoor Unit 7 4 Refrigerant System Diagram 8 5 Electrical Part 9 5 1 Wiring Diagram 9 5 2 PCB Prin...

Страница 3: ...1 Technical Information 1 Summary Part Technical Information Indoor Unit Outdoor Unit IEWQ036J3A RWI100 ICHQ036J3A RLH100 Remote Controller...

Страница 4: ...unit IEWQ036J3A RWI100 Indoor Unit Product Code CB434N14900 CB432N22800 Fan Type Cross flow Diameter Length DXL mm 108X522 7 Fan Motor Cooling Speed SH H MH M ML L SL r min 1550 1300 1200 1100 1000 95...

Страница 5: ...W mm 994X57 1X748 Fan Motor Speed rpm 880 Output of Fan Motor W 90 Fan Motor RLA A 0 65 Fan Motor Capacitor F Air Flow Volume of Outdoor Unit m3 h 4000 Fan Type Axial flow Fan Diameter mm 550 Defrosti...

Страница 6: ...7 5m Conditions Indoor DB20 C WB15 C Outdoor DB7 C WB6 C Indoor air flow High Pipe length 7 5m Conditions Indoor DB20 C WB15 C Outdoor DB7 C WB6 C Indoor air flow High Pipe length 5m Cooling Heating...

Страница 7: ...t Inlet and outlet pipe temperature of heat exchanger Fan speed of indoor unit Fan speed of outdoor unit Compressor frequency Hz Indoor Outdoor P MPa T1 C T2 C 27 19 35 24 36K 0 9 to 1 2 12 to 14 43 t...

Страница 8: ...6 Technical Information 3 Outline Dimension Diagram 3 1 Indoor Unit Model W H D 36K Unit mm W D 295 90 40 350 254 746 70 70 H 28K 90 150 54 168 5 462 159 5 55 55 54 1350 326 253...

Страница 9: ...7 Technical Information 3 2 Outdoor Unit Unit mm 1003 790 395 610 920 370 427...

Страница 10: ...ion Liquid pipe 1 4 6mm Gas pipe 5 8 16mm Indoor unit Outdoor unit COOLING HEATING 4 Way valve Discharge Suction Heat exchanger evaporator Heat exchanger condenser Valve Valve Liquid pipe side Gas pip...

Страница 11: ...gle of horizontal lover for this model 60000700130505 3OHDVH GRQ W WRXFK DQ HOHFWURQLF FRPSRQHQW RU WHUPLQDO ZKHQ WKH PDFKLQH LV UXQQLQJ VWRSSLQJ RU KDV EHHQ SRZHUHG RII IRU OHVV WKDQ PLQXWHV WR SUHYH...

Страница 12: ...RU KDV EHHQ SRZHUHG RII IRU OHVV WKDQ PLQXWHV WR SUHYHQW WKH ULVN RI HOHFWULF VKRFN 51 1 20 11 5 1 B 1 1 8 3 1 1 1 8 7 1 225 81 7 5 1 1 8 2 7 50 1 0 1 7 32 5 1 7 6 1625 203 9 8 35 17 5 8 7 2 5 3 1 1 0...

Страница 13: ...ay used for controlling wire 6 Auto key 7 up down swing interface 8 WIFI 9 Interface of ambient temperature sensor 10 Interface of tube temperature sensor 11 Display board 12 Interface of communicatio...

Страница 14: ...re cooling temperature sensor 7 Terminal of low pressure protection 12 Terminal of live wire 3 Terminal of electronic expansion valve 8 Terminal of outdoor fan 13 Terminal of communication 4 Terminal...

Страница 15: ...oller 16 30 61 86 F Fan speed auto low speed low medium speed medium speed medium high speed high speed 3 FAN button This button is used for setting Fan Speed in the sequence that goes from AUTO to th...

Страница 16: ...sequence stated above Press this button can select left right swing angle Fan blow angle can be selected circularly as below button no display stops at current position 6 7 main unit setting temperatu...

Страница 17: ...use remote controller to cancel it temperature or low temperature in order to avoid detecting inaccurate the remote controller near the object of high When I FEEL function is turned on the remote cont...

Страница 18: ...CLOCK buttons simultaneously to start up or turn off energy saving function When energy saving function is startedup SE will be shown on remote controller and air conditioner will adjust the set tempe...

Страница 19: ...ons simultaneously again to exit 8 heating function heating function has been set under Replacement of batteries in remote controller THREE TIMERS TWO TIMERS TIMER CANCELLATION NOTE 1 Press the back s...

Страница 20: ...re setting range is 16 30 and the indoor unit displays operation icon cooling icon and set temperature Protection Functions Antifreezing protection If the system is under antifreezing protection the c...

Страница 21: ...rotection is detected the compressor and the outdoor fan will stop operation and the indoor fan will operate at low speed When the antifreezing protection is eliminated and the compressor has been sto...

Страница 22: ...rate according to previous setting status Timer OFF If timer OFF is set at unit OFF the system will keep standby status If timer OFF is set at unit ON upon OFF time reaches the unit will stop operatio...

Страница 23: ...erature display returns some models if set temperature display is set by the remote controller present set temperature will be displayed 10 Locked protection to PG motor 9 Display When starting the fa...

Страница 24: ...8 32 Ambient temperature Fahrenheit display temperature o F Fahrenheit o F Celsius o C Fahrenheit display temperature o F Fahrenheit o F Celsius o C Fahrenheit display temperature o F Fahrenheit o F...

Страница 25: ...steps A Cut the pip Confirm the pipe length according to the distance of indoor unit and outdoor unit Cut the required pipe with pipe cutter B Remove the burrs Remove the burrs with shaper and prevent...

Страница 26: ...0 63 72 2 439 111 0 737 5 63 46 34 10 2 73 2 358 112 0 717 4 60 23 35 9 779 74 2 28 113 0 697 3 57 18 36 9 382 75 2 206 114 0 678 2 54 31 37 9 003 76 2 133 115 0 66 1 51 59 38 8 642 77 2 064 116 0 642...

Страница 27: ...4 61 34 13 59 73 3 144 112 0 956 4 80 31 35 13 04 74 3 04 113 0 93 3 76 24 36 12 51 75 2 94 114 0 904 2 72 41 37 12 76 2 844 115 0 88 1 68 79 38 11 52 77 2 752 116 0 856 0 65 37 39 11 06 78 2 663 117...

Страница 28: ...2 101 3 22 15 362 9 24 51 41 63 10 93 102 3 13 14 342 8 25 49 19 64 10 54 103 3 04 13 323 9 26 47 08 65 10 18 104 2 96 12 306 2 27 45 07 66 9 83 105 2 87 11 289 6 28 43 16 67 9 49 106 2 79 10 274 29 4...

Страница 29: ...OMEGA IEWQ HQ High Wall Inverter Technical Manual info otecomega com www otecomega com IEWQ CHQ I3A TM1R0622 info otecomega com www otecomega com...

Отзывы: