background image

OS423-LS (with white LED Flashlight)

Thermometer

T

Thermometer

Operating Instructions

Operating Instructions

The OS423-LS is a non-contact infrared thermometer with mathematical modes for the Infrared function.

(Default Screen)

Simply aim the thermometer at the measure target with Lens (_

8

) and press Meas. key (_

6

) to display the surface

temperature. The Distance:Spot is 30:1. Please make sure the target area is within the field of view.

FUNCTION

Press Emissivity key (_

1

) for setting the emissivity

Press Emissivity key (_

1

), then press Up key (_

4

) or Down key (_

2

) to

set the emissivity

, then press

Mode key (_

5

) to confirm it. The emissivity can be changed from 0.10 (10E) to 1 (100E).

Press Mode key (_

5

) for scrolling more display function as follows.

Here will show the emissivity data. (The default emissivity is 0.95.)

Press Mode key (_

5

) for the

Maximum (MAX), Minimum (MIN), Different between MAX and

MIN (DIF) and Average (AVG) modes. During the measurement, the special modes reading will
be displayed beside the mode icon.

Press Up key (_

4

) or Down key (_

2

) key to change the

 High Alarm (HAL) 

or

 Lo Alarm (LAL)

, then

press Meas. key (_

6

) to confirm it. For example: When the reading 26.9

o

C < LAL 27

 o

C, the Low icon

will flash and you will hear a beep sound.

** The thermometer will automatically shut off if left idle for more than 60sec.

ADD VALUE

Press Up key (_

4

) for

LOCK mode

ON/OFF. The lock mode is particularly useful for

continuous monitoring of temperatures for up to 60 minutes.

In MAX, MIN, DIF,
AVG mode:

Press Down key (_

2

) for

o

C

or

o

F transferred.

and press Up key (_

4

) for

backlight

function

ON/OFF.

In all modes: First
hold on the Meas.
key (_

6

)

and press Down key (_

2

) for

 laser circle/dot function 

ON/OFF.

 

(With flash light be turned on in the same time as laser)

U.S. PAT. B1 5,368,392; 5,524,984; 5,727,880; 5,823,678; 5,823,679; 6,123,453; 6,267,500 B1; 6,341,891 B1; 6,377,400 B1; 6,540,398 B2 ; 
6,614,830 B1; 6,633,434 B2; 6,659,639; 6,901,089 B1, 7,052,175 / Canada 2,114,806; 2,317,734 / France 2 756 920; 2 767 921; 2,773,213; 2 773 
214 / Germany G 94 22 197.9; G 94 22 203.7, 19828454/ Holland 1007752; / U.K. Registered 2,237,493; 2,320,324; 9726133.3 / EPO 0 644,408 
B2; EPO 1 085 307 A1, EPO 1 065 484 B1, EPO 1 065 483 B1. Other U.S. and International Patents Pending.

Circle/Dot
Laser

Содержание OS423-LS

Страница 1: ...omega com e mail info omega com For latest product manuals omegamanual info User sGuide OS423 LS Non contact Infrared Thermometer with White LED Flashlight Shop online at MADE IN TAIWAN ...

Страница 2: ...y _ 4 or Down key _ 2 key to change the High Alarm HAL or Lo Alarm LAL then press Meas key _ 6 to confirm it For example When the reading 26 9 o C LAL 27 o C the Low icon will flash and you will hear a beep sound The thermometer will automatically shut off if left idle for more than 60sec ADD VALUE Press Up key _ 4 for LOCK mode ON OFF The lock mode is particularly useful for continuous monitoring...

Страница 3: ...rvice Department for further assistance _ __ _ Hi or Lo is displayed when the temperature being measured is outside of the measurement range BATTERIES The thermometer incorporates visual low battery indication as follows Battery OK measurements are possible Battery Low battery needs to be replaced measurements are still possible Battery Exhausted measurements are not possible When the Low Battery ...

Страница 4: ...y nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear installation or activity medical application used on humans or misused in any way OMEGA assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or dam...

Отзывы: