manualshive.com logo in svg
background image

 

 

 

 

 

Installation Instructions 

HINTS FOR EXHAUST DUCT INSTALLATION 

The following rules must be strictly followed to obtain optimal air extraction: 
 

 

Keep expansion pipe short and straight. 

 

Do not reduce the size or restrict the expansion pipe. 

 

When using the expansion pipe always install the pipe pulled taut to minimize pressure loss. 

 

Failure to observe these basic instructions will reduce the performance and increase noise levels of 
the cooker hood. 

 

Any installation work must be carried out by a qualified electrician or competent person. 

 

Do not connect the ducting system of the hood to any existing ventilation system which is being 
used for any other appliance, such as warmer tube, gas tube, hot wind tube. 

 

The angle of the bend of the expansion pipe should not be less than 120º; you must direct the pipe 
horizontally, or, alternatively, the pipe should go up from the initial point and should be led to an 
outer wall. 

 

After the installation, make sure that the cooker hood is level to avoid grease collection at one end. 

 

Ensure the expansion pipe selected for installation complies with relevant standards and is fire 
retardant. 

 
 
 
 
 

              

 

WARNING: 

 

For safety reason, please use only the same size of fixing or mounting screws which are 
recommended in this instruction manual. 

 

Failure to install the screws or fixing device in accordance with these instructions may result in 
electrical hazards. 

 
 
 
 
 
 
 
 
 
 

Содержание ORCG60MB

Страница 1: ...Instruction Manual OMEGA CURVED GLASS RANGEHOOD ORCG60MB ORCG90MB...

Страница 2: ...iance such as warranty registration manuals features and specifications please visit omegaappliances com au if you are in Australia and omegaappliances co nz if you are in New Zealand or contact our C...

Страница 3: ...rves the right to alter specifications and appearances without notice Contents Important Safety Warnings 4 Appliance Details 5 Installation Instructions 6 Operating Instructions 10 Maintenance and Cle...

Страница 4: ...ervice centre or similarly qualified persons to avoid a hazard 11 For indoor use only 12 It is recommended to operate the range hood prior to cooking 13 It is recommended to leave the range hood in op...

Страница 5: ...ils Rangehoods ORCG60MB ORCG90MB Rated Voltage 220 to 240V 50Hz Motor Input Power 190W Lamp LED 2 x 1 5W Rated Input Power 193W Max Airflow 750m3 Hr Outlet Diameter 150 mm Power Connection 10 A Plug O...

Страница 6: ...V flap because the outlet may vary according to different models and configurations To mount the V flap 1 you should 1 Mount two half parts 2 into the body 6 2 The pin 3 should be top oriented 3 The a...

Страница 7: ...r hanging the hood and inside chimney bracket Drill 4 pcs 8 holes they are for fixing inside chimney bracket and the hood and keep the hood level The fixed position of the outside chimney bracket is t...

Страница 8: ...crews here should be sure the inside chimney can be moved inside freely See pic 6 8 After adjusting the height fix the body with 2 pcs of ST4 30mm safety screws Note The two safety vents are positione...

Страница 9: ...ny existing ventilation system which is being used for any other appliance such as warmer tube gas tube hot wind tube The angle of the bend of the expansion pipe should not be less than 120 you must d...

Страница 10: ...or light of lamp button and power button will lit on Press lamp button again to turn off the lights Indicator light of lamp button and power button will be off And recycle like this 4 Press the High b...

Страница 11: ...be cleaned with warm soapy water or a cloth The stainless steel must be cleaned regularly e g Weekly to ensure a long life expectancy Dry with a clean soft cloth A specialized stainless steel cleaning...

Страница 12: ...l the light back ILCOS D code for this lamp is DSR 1 5 65 S 64 LED modules round lamp Max wattage 2 1 5 W Voltage DC 12V Dimensions NOTE Always switch off the electricity supply before carrying out an...

Страница 13: ...t Switch power outlet on Oil leakage One way valve and the air ventilation entrance are not tightly sealed Take down the one way valve and seal with sealant Leakage from the connection of U shaped sec...

Страница 14: ...14...

Страница 15: ...1...

Отзывы: