will automatically terminate the recording and save any data recorded up to that
point. The LED will stop flashing and the OM-DLAC will not allow a new record-
ing to be started until the battery has been replaced. Recorded data can be re-

trieved regardless of the condition of the battery.

When the logger will not be used for an extended period, or when the battery is
exhausted, it is strongly recommended to remove the battery to avoid damage
to the logger from battery leakage. 

Use only Alkaline batteries in the

OM-DLAC. Substitution of a different battery can result in reduced perform-
ance or permanent damage to this instrument.

To replace the OM-DLAC’s battery follow the steps below:

1.

 

Make sure the logger is not set in the recording position. If so, slide the door
open. Any information recorded up to this point will not be lost and is auto-
matically saved.

2.

 

Remove the rear battery cover.

3.

 

The battery and battery clip may be extended from the battery compartment
to facilitate replacement.

4.

 

Remove the battery from the logger and dispose of properly. To assure
proper reset of the logger wait at least one minute before connecting new
battery.

5.

 

Line up the connector of the new battery and push onto the pins of the bat-
tery clip with a firm motion. 

Do NOT reverse the battery connection, even

momentarily, as this can result in loss of data or permanent damage to
the logger

.

6.

 

Place the battery in the battery compartment of the OM-DLAC.

7.

 

Replace the battery cover.

Once the battery has been replaced it will be necessary to reset the logger’s
internal clock. Refer to the section, “Setting the Data Logger” for instructions on
how to do this.

Содержание OM-DLAC

Страница 1: ...AC Current Data Logger 1...

Страница 2: ...4 If you are using Windows 3 1 click on Program Manager 5 Select FILE and select RUN 6 Type A SETUP and press Enter To get the latest product information and current release of the Data Logger to PC s...

Страница 3: ...s are indicated in parentheses next to the recording interval The recording intervals that correspond to charts used by the OM DP3 Data Plotter show the appropriate chart selection instead of a maximu...

Страница 4: ...eached its maximum capacity of 16 000 samples NOTE If the battery is exhausted during a recording the OM DLAC will automatically terminate the recording and save any data recorded up to that point The...

Страница 5: ...DINGS 1 Plug the PC interface into the printer port of the computer being used to set the OM DLAC Plug the OM DLAC being read to the cable from the PC in terface 2 Start the Data Logger program If you...

Страница 6: ...To zoom to a particular part of the graph place the mouse cursor in a corner of an imaginary box that will enclose the area of interest 3 Press and hold the left mouse button and move the cursor in a...

Страница 7: ...t listing or a plotted graph 2 To view a recording as text when a graph is on the screen click the Text button located in the display box 3 Use the Windows scroll bar on the right hand side of the scr...

Страница 8: ...the OK button or press the Enter key to continue If you have typed a password before and you don t want password protection for the calibration function you can input None as the new password and thi...

Страница 9: ...r is not set in the recording position If so slide the door open Any information recorded up to this point will not be lost and is auto matically saved 2 Remove the rear battery cover 3 The battery an...

Страница 10: ...rature 40 F to 170 F 40 C to 76 C Time Accuracy 100ppm 75 F Current Range 0 to 300 Amps AC using supplied clamp on probe Current Resolution 0 1 Amp AC Current Accuracy 5 Memory Capacity 16 000 Data Sa...

Страница 11: ...uter Using the OM DP3 you can plot recorded information from a data logger or change the settings of a data logger prior to making a different data recording The OM DP3 can be operated from batteries...

Отзывы: