FCC COMPLIANCE AND REQUIREMENTS 

 

Omega’s OM-CP-RF series products operate in an “unlicensed” operation band, meaning 

the end-user does not need to do anything special (such as obtain a license) to legally make 

use of the product. Omega has performed all the required testing and certification to ensure 
that these products meet the requirements for unlicensed operation outlined in 47 CFR Part 

15.231 of the FCC rules. However, the user must understand and adhere to the following 

notes and guidelines: 
 

Any user changes or modifications that are not expressly approved by Omega 

Engineering, Inc. may void the user’s authority to operate the device per FCC code, 
section 15.231. 

 

FEDERAL COMMUNICATIONS COMMISSION (FCC) NOTICE 

The following FCC IDs are associated with the devices covered by this manual: 

 

PRODUCT FCC 

ID 

TRADE 

NAME 

OM-CP-RFTemp101A 

RUYBOARDRF 

Omega Engineering, Inc. 

OM-CP-RFRHTemp101A 

RUYBOARDRF 

Omega Engineering, Inc. 

OM-CP-RFTC4000A 

RUYBOARDRF 

Omega Engineering, Inc. 

OM-CP-RFRTDTemp101A  RUYBOARDRF 

Omega Engineering, Inc. 

OM-CP-RFpHTemp101A 

RUYRFPHTEMP 

Omega Engineering, Inc. 

OM-CP-RFVolt101A 

RUYBOARDRF 

Omega Engineering, Inc. 

OM-CP-RFProcess101A 

RUYBOARDRF 

Omega Engineering, Inc. 

OM-CP-RFPulse101A 

RUYBOARDRF 

Omega Engineering, Inc. 

 

The following statement applies to all of the devices covered in this manual: 
 

This device complies with Part 15 of the FCC Rules. Operation is subject to the 

following two conditions: (1) this device may not cause harmful interference and 

(2) this device must accept any interference received, including interference that 
may cause undesired operation.

 

 

NOTE:

 This equipment has been tested and found to comply with the limits for a Class B 

digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This 

equipment generates, uses and can radiate radio frequency energy and, if not installed and 
used in accordance with the instructions, may cause harmful interference to radio 

communications. However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful interference to radio or 

television reception, which can be determined by turning the equipment off and on, the user 
is encouraged to try to correct the interference by one of more of the following measures: 

 

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

 

Connect the equipment into an outlet on a circuit different from that to which the 
receiver is connected. 

 

Consult the dealer or an experienced radio/TV technician for help. 

 

Содержание OM-CP-RF Series

Страница 1: ......

Страница 2: ...78280 Guyancourt France TEL 33 0 1 61 37 2900 FAX 33 0 1 30 57 5427 Toll Free in France 0800 466 342 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany TEL 49 0 7056...

Страница 3: ...m 11 Complex RFExtender System 12 Module Address and Receiver Address Mask 12 Receiver Address Mask Example 13 BATTERY LIFE 14 BATTERY LIFE 15 OPERATING ENVIRONMENT 16 SYSTEM PERFORMANCE AND RELIABILI...

Страница 4: ...s101A DC Current Recorder and Wireless Transmitter OM CP RFPulse101A Pulse Recorder and Wireless Transmitter These products have onboard memory in addition to the wireless transmitter so they can comp...

Страница 5: ...ne of the OM CP RF series wireless enabled data loggers An RFC101A wireless receiver module and power supply for receiving wireless transmissions from the data logger An IFC110 interface cable for com...

Страница 6: ...r WIRELESS CONFIGURATION DIALOG Figure 3 The Wireless Configuration dialog The Wireless Configuration dialog shown in Figure 3 allows the user to select from a variety of operating modes to meet the r...

Страница 7: ...anual Transmitter Options The transmitter module has four configuration options Two of these options pertain to enabling and disabling the transmitter under different operating conditions and two pert...

Страница 8: ...copies of the data packet increasing the likelihood that one of the copies will be received even when the other is lost due to interference Each packet always contains error detection to ensure that...

Страница 9: ...ce This image is stored on the PC s hard disk so it is retained even when the software or PC is shut down The software then refers to the device image when receiving a transmission to fill in the info...

Страница 10: ...ter mode or the real time chart recording feature of the software will avoid RF interference 3 Randomize the transmission interval This option is selected from the wireless configuration menu Selectin...

Страница 11: ...ission attempt they cannot possibly collide during the second they are scheduled to select different sots for the second attempt For three or more transmitters it is possible to collide with one trans...

Страница 12: ...37 347 349 353 359 367 373 379 383 389 397 401 409 419 421 431 433 439 443 449 457 461 463 467 479 487 491 499 503 509 521 523 541 547 557 563 569 571 577 587 593 599 601 607 613 617 619 631 641 643 6...

Страница 13: ...ed Prime Numbers 29 23 19 17 13 179 173 167 163 157 Transmission Intervals More critical devices 290 seconds 230 seconds 190 seconds 170 seconds 130 seconds 1790 seconds 1730 seconds 1670 seconds 1630...

Страница 14: ...ble instead of through the wireless transmitter and the RFExtender transmits the serial data back to the PC This setup has two advantages the logger can be launched downloaded and configured without b...

Страница 15: ...ld be assigned node address zero and the remote nodes may be sequential starting with one Note that this is how the module addresses in Figure 6 were generated The receiver address mask instructs the...

Страница 16: ...FF00 0100 Node FFFF 0102 FFFF 0101 Node FFFF 0103 Node FFFF 0108 Node Node FFFF 0107 FFFF 0106 Node FFFF 0104 Node FFFF 0105 Node RFEXTENDER TRANSCIEVER MASK ADDRESS RF SERIES DATA LOGGER IFC110 INTER...

Страница 17: ...ctivity rate for cases where the logger and transmitter operate at different rates use the faster rate for estimation The calculations assume that the device is configured and deployed then downloaded...

Страница 18: ...Transmitter location Keep the transmitter as close to the receiver as possible If either the transmitter or receiver must be in an enclosed area keep the other inside the same area This is especially...

Страница 19: ...g Inc OM CP RFPulse101A RUYBOARDRF Omega Engineering Inc The following statement applies to all of the devices covered in this manual This device complies with Part 15 of the FCC Rules Operation is su...

Страница 20: ...M CP RFRHTemp101A 4953A BOARDRF Omega Engineering Inc OM CP RFTC4000A 4953A BOARDRF Omega Engineering Inc OM CP RFRTDTemp101A 4953A BOARDRF Omega Engineering Inc OM CP RFpHTemp101A 4953A RFPHTEMP Omeg...

Страница 21: ...therwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...

Страница 22: ...ty Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial...

Отзывы: