Device Operation

Connecting and Starting the data logger

1.  Once the software is installed and running, plug the interface cable into the data logger. 
2.  Connect the USB end of the interface cable into an open USB port on the computer.
3.  The device will appear in the 

Connected Devices

 list, highlight the desired data logger.

4.  For most applications, select “

Custom Start

” from the menu bar and choose the desired start method, 

reading rate and other parameters appropriate for the data logging application and click “

Start

”. (

Quick 

Start

” applies the most recent custom start options, “

Batch Start

” is used for managing multiple loggers at 

once, “

Real Time Start

” stores the dataset as it records while connected to the logger.)

5.  The status of the device will change to “

Running

”, “

Waiting to Start

” or “

Waiting to Manual Start

”, 

depending upon your start method.

6.  Disconnect the data logger from the interface cable and place it in the environment to measure. 

Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point 
the device cannot be restarted until it has been re-armed by the computer.

Downloading data from a data logger

1.  Connect the logger to the interface cable.
1.  Highlight the data logger in the Connected Devices list. Click 

“Stop”

 on the menu bar. 

2.  Once the data logger is stopped, with the logger highlighted, click 

“Download”

. You will be prompted to 

name your report.

3.  Downloading will offload and save all the recorded data to the PC. 

Product Maintenance

Battery Replacement

Materials:

 

3/32” HEX Driver (Allen Key)
Replacement Battery (OM-CP-BAT103)

1.  Remove the cover from the device by unscrewing the four screws.
2.  Remove the battery from its compartment and unsnap it from the connector. 
3.  Snap the new battery into the terminals an verify it is secure.
4.  Replace the cover taking care not to pinch the wires. Screw the enclosure back together securely.

Note: Be sure not to over tighten the screws or strip the threads.

Recalibration

The OM-CP-OCTRTD standard temperature calibration is at 2 points, 50 

 and 150 

.

Recalibration is recommended annually for any Omega data logger; a reminder is automatically displayed in 
the software when the device is due.

OM-CP-OCTRTD

Содержание OM-CP-OCTRTD

Страница 1: ...EET Xxxxx Xxxxxx Xxxxx Xxxxxx Xxxxxxxx M0000 0016 INSTRUCTION SHEET Shop online at omega comSM e mail info omega com Office Jl Radin Inten II No 62 Duren Sawit Jakarta 13440 Indonesia Workshop Jl Pahlawan Revolusi No 22B Jakarta 13430 Indonesia Phone 021 8690 6777 Hunting Fax 021 8690 6777 Mobile 62 816 1740 8925 Fax 021 8690 6771 ...

Страница 2: ...uarantee the accuracy To determine whether or not the 3 wire RTD probe will work the resistance between the two same colored wires should be less than 1 Ω Note Please contact the manufacturer of the RTD probe for questions on the resistance Installation Guide Installing the Interface cable OM CP IFC200 Insert the device into a USB port The drivers will install automatically OM CP IFC110 Plug the s...

Страница 3: ...is reached or the device is stopped At this point the device cannot be restarted until it has been re armed by the computer Downloading data from a data logger 1 Connect the logger to the interface cable 1 Highlight the data logger in the Connected Devices list Click Stop on the menu bar 2 Once the data logger is stopped with the logger highlighted click Download You will be prompted to name your ...

Страница 4: ...ment 20 C to 60 C 4 F to 140 F 0 RH to 95 RH non condensing Material Anodized Aluminum Weight 15 9 oz 450 g Dimensions 3 5 in x 4 4 in x 1 5 in 89 mm x 112 mm x 39 mm OM CP OCTRTD General Specifications OM CP OCTRTD Battery Warning WARNING FIRE EXPLOSION AND SEVERE BURN HAZARD DO NOT SHORT CIRCUIT CHARGE FORCE OVER DISCHARGE CRUSH PENETRATE OR INCINERATE BATTERY MAY LEAK OR EXPLODE IF HEATED ABOVE...

Отзывы: