background image

 

 
 
 
 
 

FIGURE 4 

 

 

 

NOMINAL GAS  CONSUMPTION 

 

Gas Type; 

Natural Gas 

 

 

Burner 

Injector size mm 

MJ/h - NG 

(1.00 kPa) 

Small 

.90 

3.6 

Medium 

1.15 

6.3 

Large 

1.55 

10.8 

Wok 

1.75 

13.2 

Fish 

1.55 

10.8 

 

 

ULPG 

 

 

Burner 

Injector size mm 

MJ/h - NG 

(2.75 kPa) 

Small 

0.55 

4.0 

Medium 

0.66 

6.3 

Large 

0.85 

10.2 

Wok 

0.98 

12.6 

Fish 

.  . 

0.85 

10.2   

 
 

 

11 

 

 

 
 
 
 
 
 
 
 

 

ig. 

Содержание OG60WA

Страница 1: ...INSTALLATION OPERATING INSTRUCTIONS GAS HOBS MODELS OG30XA OG60XA OG60WA OG61XA OG61WA OG62XA OG63XA OG64XA OG65XA OG66XA OG67XA OG70XA OG71XA OG72XA OG90XA OG91XA OG92XA OGG64A OGG75A OGG96A...

Страница 2: ...It contains all the necessary instructions for maintaining the appearance and functional qualities of the hob INSTRUCTIONS FOR THE INSTALLER these are for the Authorised Person who must carry out a su...

Страница 3: ...proper The Manufacturer declines all responsibility for improper use DO NOT leave the packing in the home environment Separate the various waste materials and take them to the nearest special garbage...

Страница 4: ...MARINE CRAFT OR IN CARA VANS IT SHALL NOT BE USED AS A SPACE HEATER DO NOT spray aerosols in the vicinity of this appliance while it is in operation The Manufacturer declines all responsibility for da...

Страница 5: ...ce is to be connected to NG then the pressure regulator supplied MUST be fitted to the gas inlet A pressure test point for checking the gas pressure is supplied either with the regulator or as a separ...

Страница 6: ...ensure the supply to the appliance is operating at 2 75kPa Clearance Above and Around Domestic Cookers 200mm from the edge of the burner to combustible materials on vertical sides of the appliance 65...

Страница 7: ...the clearance between the highest part of the hob of the cooking appliance and a range hood be less than 600mm or for an overhead exhaust fan 650mm Any other downward facing combustible surface less...

Страница 8: ...riphery of the nearest burner to a horizontal combustible surface is less than 200mm then E shall be 10mm or more or the horizontal surface shall be above the trivet See insets above NOTES 1 Requireme...

Страница 9: ...ow the gas to be turned off and disconnected for servicing and removal of the appliance as required from the gas supply Before the appliance is operated make certain all relevant parts are placed in t...

Страница 10: ...iances cannot accept responsibility for any damage to persons or to property arising from faulty connection or non connection to earth Before connecting installing or servicing the hob the plug should...

Страница 11: ...a 7mm tube spanner Replace in or der with new injectors make sure the correct size injectors are used See data on underside of hob for size or refer to page 10 for chart 6 The regulator is required to...

Страница 12: ...l Gas Burner Injector size mm MJ h NG 1 00 kPa Small 90 3 6 Medium 1 15 6 3 Large 1 55 10 8 Wok 1 75 13 2 Fish 1 55 10 8 ULPG Burner Injector size mm MJ h NG 2 75 kPa Small 0 55 4 0 Medium 0 66 6 3 La...

Страница 13: ...ensure all control knobs are in the OFF position and the appliance has cooled completely Before any maintenance can be carried out you MUST disconnect the appliance from the electricity supply CLEANIN...