INTRODUCTION
MARKINGS: include the following:
(i)
Gas Type Label: fixed to the underside of the appliance.
(ii)
Data plate: fixed to the underside of the appliance stating Model
Number, AGA or SAI-GLOBAL Approval Number, Gas operating pressure,
Nominal Gas Consumption etc.
(iii)
AGA or SAI-GLOBAL label fixed to the underside: showing that the
appliance conforms to the Standards.
INSTALLATION INSTRUCTIONS:
Refer to the Data Plate on the underside of the appliance for information on gas
consumption, injector sizes etc.
Refer to Figure 5 for dimension information and cut out size for bench tops.
This hotplate is suitable for installation with Natural Gas or ULPG.
Refer to data plate on appliance for relevant burner pressure and appropriate
injector sizes. When the appliance is to be connected to NG, then the pressure
regulator supplied MUST be fitted to the gas inlet. A pressure test point (for
checking the gas pressure) is supplied either with the regulator or as a separate
fitting for ULPG.
Connection of the appliance to the gas supply MUST be in accordance with the
requirements of AS 5601. A ½”BSP connector at the inlet is recommended and
the gas supply line to the appliance must be of adequate length to allow
sufficient withdrawal of the appliance for service or disconnection and be:
a)
annealed copper pipe, or;
b)
a hose assembly complying with the requirements of AS1869, Class
'B', 1Omm diameter, maximum length 1OOOmm.
When the installation is completed, the hotplate will require to be leak tested
and the burner operating pressure and flame checked and adjusted
accordingly. The duplicate data plate should be attached to an area adjacent to
the appliance eg. In a cupboard which is accessible for reading the appliance
details.