part
3
O
PERATION
:
C
ONFIGURATION
M
ODE
74
Command Formats
cont.
Description:
SETPOINT.23 ~ 0 means 3 bytes x 8 bit positions (2 characters in each byte).
SETPOINT.23
= 0 = positive sign
SETPOINT.22~20
= 000 - Not Allowed
SETPOINT.19~0
= Setpoint data
1 = negative sign
001 - Decimal Point 1 (XXXX.)
010 - Decimal Point 1 (XXX.X)
011 - Decimal Point 1 (XX.XX)
101 - Decimal Point 1 (X.XXX)
*Process Only
For 100.0: Positive sign = 0, Decimal Point 2 = 010 Bin, Setpoint data 1000 = 3E8 Hex = 001111101000 Bin
The command data =
0010
0000
0000
0011
1110
1000 Bin = 2003E8 Hex
A
0
0
3
E
8
Hex
Send *W01 2 003E8, where
*W01 - *<ccc> - write to Setpoint 1 (Table 3.1)
2003E - <data> - Setpoint data including sign and decimal point (Table 3.2)
Содержание MICROMEGA CN77000 series
Страница 4: ...NOTES ...
Страница 19: ...SETUP part 2 11 Dip Switch Settings ...
Страница 31: ...Figure 3 2 Flowchart for Input Type OPERATION CONFIGURATION MODE part 3 23 ...
Страница 36: ...Figure 3 3 Flowchart for Reading Configuration part 3 OPERATION CONFIGURATION MODE 28 ...
Страница 45: ...Figure 3 5 Flowchart for Loop Break OPERATION CONFIGURATION MODE part 3 37 ...
Страница 49: ...OPERATION CONFIGURATION MODE part 3 41 Figure 3 6 Flowchart for Output 1 ...
Страница 59: ...OPERATION CONFIGURATION MODE part 3 51 Figure 3 7 Flowchart for Output 2 ...
Страница 65: ...OPERATION CONFIGURATION MODE part 3 57 Figure 3 8 Flowchart for Ramp Soak ...
Страница 69: ...OPERATION CONFIGURATION MODE part 3 61 Analog Output Option Figure 3 9 Flowchart for Analog Output Option ...
Страница 72: ...part 3 OPERATION CONFIGURATION MODE Communication Option Figure 3 10 Flowchart for Communication Option 64 ...
Страница 96: ...part 3 OPERATION CONFIGURATION MODE 88 Remote Setpoint Option Figure 3 11 Flowchart for Remote Setpoint ...