Step 4: Check The Status Indicator Lights
Using Linkr To Monitor A Home / Building Alarm
Linkr can be installed for direct monitoring of any building alarm. It can
alert the user of any alarm trigger condition and can control quick arm &
disarm functions if the alarm panel supports it.
BLACK ground wire (required):
Connect to the alarm panel (-)12v DC source.
RED +12v constant power wire (required):
Connect to the alarm panel (+)12v DC source.
BLUE, GREEN, & ORANGE (-) output wires (optional):
Typically, you will need to wire relays to connect/disconnect the key input terminals
(aka ‘key zone’) on the panel. In most cases, resistors are required. See the panel
instructions for more info.
BROWN (+) & BROWN/WHITE (-) alarm trigger input wires:
If the siren/bell output is constant when triggered, use the BROWN wire. If the output
is pulsed, use the BROWN/WHITE wire. Be sure the polarity matches, convert with a
relay as needed.
After powering the device, turn on the vehicle ignition and allow a few
minutes to get the proper indicators. Make sure the vehicle is out in the
open so the module has a clear view to the sky.
CEL GPS PWR
BATT
ON
OFF
Indicator Lights
LED
ON
Fast Flashing
Slow Flashing
OFF
CEL
(green)
Transmitting
Searching the
cellular network
Connected to
cellular network
-
GPS
(blue)
GPS
connected
Searching for GPS
GPS data error
GPS is off
PWR
(red)
Power
connected
& battery is
charged
Power connected,
internal battery is
charging
Power is not
connected, backup
battery is ON.
No Power