AC CURRENT (40Hz-500Hz) (Put conductor at the center of the jaws)
Ranges: 430A,700A
Resolution: 100mA
Accuracy: ±(1.75%rdg + 5dgts) on 50Hz-60Hz
±(3.5%rdg + 5dgts) on 40Hz-500Hz
*700A to 1000A(50Hz/60Hz): ±(2.5%rdg + 5dgts)
Overload protection: 1000Aac max. for 1 minute
TEMPERATURE(K-TYPE)
Ranges: -20°C to 850°C
-4°F to 1562°F
Accuracy: ±(0.5%rdg + 3dgts) on °C range
±(0.5%rdg + 6dgts) on °F range