4
CONTINUITY
Audible indication: less than 50
W
±30
W
Overload protection: 600VDC or AC rms
DIODE TEST
Test current: 1.0mA±0.6mA
Accuracy: ±(10.0%rdg + 3dgts)
Open circuit volts: 3.0Vdc typical
Overload protection: 600VDC or AC rms
FREQUENCY
Ranges: 430Hz,4.3KHz
Resolution: 0.1Hz
Accuracy: ±(1.0%rdg + 3dgts)
Sensitivity: 1.0Vrms min
Effect reading: 100-4300
Overload protection: 600VDC or AC rms
DC CURRENT (Put conductor at the center of the jaws)
Ranges: 430A,700A
Resolution: 100mA
Accuracy: ±(1.5%rdg + 5dgts)
*700A to 1200A: ±(2.0%rdg + 5dgts)
Overload protection: 1200Adc max. for 1 minute
Содержание HHM596C