manualshive.com logo in svg
background image

6

OPERATION

Before taking any measurements, read the Safety Information Section.

Always examine the instrument for damage, contamination (excessive dirt,
grease, etc.) and defects. Examine the test leads for cracked or frayed
insulation. If any abnormal conditions exist do not attempt to make any
measurements.

Voltage Measurements

1. Connect the red test lead to the "V

W

" jack and the black test lead to the

"COM" jack.

2. Set the Function/Range switch to the desired voltage type (AC or DC) and

range. If magnitude of voltage is not known, set switch to the highest range
and reduce until a satisfactory reading is obtained.

3. Connect the test leads to the device or circuit being measured.
4. For dc, a (-) sign is displayed for negative polarity; positive polarity is implied.

Current Measurements

1. Set the Function/Range switch to the desired current type (AC or DC) and

range.

2. For current measurements less than 200mA, connect the red test lead to the

"mA" jack and the black test lead to the "COM" jack.

3. For current measurements over 200mA or greater, connect the red test lead

to the "10A" jack and the black test lead to the "COM" jack.

4. Remove power from the circuit under test and open the normal circuit path

where the measurement is to be taken. Connect the meter in series with the
circuit.

Содержание HHM14

Страница 1: ...OMEGA HHM14 Digital Multimeter...

Страница 2: ...l Free in Germany 0800 82 66342 e mail nl omega com e mail germany omega com Czech Republic United Kingdom ISO 9002 Certified ul Rude armady 1868 733 01 Karvina One Omega Drive Hranice Czech Repubic R...

Страница 3: ...across a high voltage high energy power source when the meter is set up for mA measurement may be very hazardous 3 Turn off power to the circuit under test before cutting unsoldering or breaking the...

Страница 4: ...ating Environment 0 C to 40 C at 70 relative humidity Storage Temperature 20 C to 60 C 0 to 80 R H with battery removed from meter Accuracy Stated accuracy at 23 C 5 C 75 relative humidity Safety Acco...

Страница 5: ...AC VOLTS True RMS Ranges 200mV 2V 20V 200V 750V Resolution 10 V Accuracy Input impedance 10MW Overload protection 500VDC or 350VAC 30 sec on 200mV range 1000VDC or 750VAC rms on other ranges Range Inp...

Страница 6: ...10dgts on 200 A to 200mA ranges 2 5 rdg 10dgts on 10A range Input protection 0 5A 250V fast blow fuse 10A 600V fast blow ceramic fuse RESISTANCE Ranges 20W 200W 2KW 20KW 200KW 2000KW 20MW Accuracy Fu...

Страница 7: ...40W 20W Overload protection 500VDC or AC rms DIODE TEST Test current 1 0mA 0 6mA Accuracy 2 0 rdg 3dgts Open circuit volts 3 3Vdc typical Overload protection 500VDC or AC rms TRANSISTOR hFE Ranges 0 1...

Страница 8: ...itch to the highest range and reduce until a satisfactory reading is obtained 3 Connect the test leads to the device or circuit being measured 4 Fordc a signisdisplayedfornegativepolarity positivepola...

Страница 9: ...er from the equipment under test 3 Connect the red test lead to the VW jack and the black test lead to the COM jack 4 Touch the probes to the test points In ohms the value indicated in the display is...

Страница 10: ...both directions 7 If the junction is measured in a circuit and a low reading is obtained with both lead connections the junction may be shunted by a resistance of less than 1kW In this case the diode...

Страница 11: ...are possible check for a blown overload protec tion fuse There are two fuses F1 for the mA jack and F2 for the 10A jack For access to fuses remove the two screws from the back of the meter and lift o...

Страница 12: ...ty or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipmen...

Страница 13: ...rs Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial pH Conducti...

Отзывы: