manualshive.com logo in svg
background image

WARRANTY/DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a
period of 

13 months

from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month

grace period to the normal 

one (1) year product warranty

to cover handling and shipping time. This

ensures that OMEGA’s customers receive maximum coverage on each product. 

If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service
Department will issue an Authorized Return (AR) number immediately upon phone or written request.
Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no
charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser,
including but not limited to mishandling, improper interfacing, operation outside of design limits, 
improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of 
having been tampered with or shows evidence of having been damaged as a result of excessive corrosion;
or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating
conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not 
limited to contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However, 
OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any
damages that result from the use of its products in accordance with information provided by
OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the
company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR 
REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF
TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF 
LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of 
OMEGA with respect to this order, whether based on contract, warranty, negligence, 
indemnification, strict liability or otherwise, shall not exceed the purchase price of the 
component upon which liability is based. In no event shall OMEGA be liable for 
consequential, incidental or special damages.

CONDITIONS:  Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic
Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical
applications or used on humans. Should any Product(s) be used in or with any nuclear installation or
activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility
as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify
OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the
Product(s) in such a manner.

RETURN REQUESTS/INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE
RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN
(AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID
PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return
package and on any correspondence.

The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent
breakage in transit. 

FOR 

WARRANTY

RETURNS, please have the 

following information available BEFORE 
contacting OMEGA:
1. Purchase Order number under which the product

was PURCHASED,

2. Model and serial number of the product under

warranty, and

3. Repair instructions and/or specific problems 

relative to the product.

FOR 

NON-WARRANTY

REPAIRS, consult OMEGA

for current repair charges. Have the following
information available BEFORE contacting OMEGA:
1.  Purchase Order number to cover the COST 

of the repair,

2. Model and serial number of the product, and
3. Repair instructions and/or specific problems 

relative to the product.

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords
our customers the latest in technology and engineering.

OMEGA is a registered trademark of OMEGA ENGINEERING, INC.

© Copyright 2009 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the
prior written consent of OMEGA ENGINEERING, INC.

Содержание HH127

Страница 1: ...omega com e mail info omega com For latest product manuals omegamanual info HH127 TC Data Logger Thermometer Shop online at User sGuide MADE IN TAIWAN ...

Страница 2: ...aged by the United Kingdom Office Toll Free 0800 466 342 TEL 33 0 161 37 29 00 FAX 33 0 130 57 54 27 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany Toll Free 0 800 6397678 TEL 49 0 7059 9398 0 FAX 49 0 7056 9398 29 e mail info omega de United Kingdom OMEGA Engineering Ltd ISO 9001 Certified One Omega Drive River Bend Technology Centre Northbank Irlam Mancheste...

Страница 3: ...s a microprocessor The HH 127 has USB and RS232 ports Accessories DC 1 5V 4 AAA batteries Rubber boot K type thermocouple x 2 pcs Users manual PC on line accessories Temp Monitor software users manual IrDA USB and IrDA RE232 transmission cable Temp Monitor software CD ...

Страница 4: ... battery immediately Do not operate the thermometer around explosive gas vapor or dust Do not apply more than the rated voltage as marked on the thermometer either between the thermocouple or between any thermocouple and earth ground Caution A Caution identifies conditions and actions that may damage the meter or the equipment under test Use the proper thermocouples function and range for your the...

Страница 5: ...Names of parts Housing IrDA output port LCD display T1 thermocouple input Function control keys T2 thermocouple input Battery seat Screw hole Reset key Battery cover T2 T1 2 ...

Страница 6: ... Third display shows T1 T2 reading Carry out set function Secondary display shows time s day month Hold display reading Battery power indicator and replacement The battery power is expressed by five sections of batteries marks When the battery mark shows and you hear a short buzzing sound this indicates the battery power is weak please immediately close the unit and replace with 4 AAA batteries to...

Страница 7: ... it will keep the last power off state dual inputs secondary display shows T2 measuring value and third display shows T1 T2 value Temperature unit key Choose temperature unit to be Centigrade C or Fahrenheit F Maximum minimum key Main secondary display show T1 T2 maximum minimum value at same time third display shows T1 T2 real time readings C F MAX MIN C F C F MAX MIN MAX MIN MAX MIN 4 ...

Страница 8: ...lative readings Third display is the stored relative value When setting up relative readings Pushing the key the third display shows set relative reading Note Set up operation for relative readings please consult the explanation for setting up relative Alarm function key Main display shows T1 or T2 reading If T1 or T2 are greater than or smaller than set up critical high value or low value of alar...

Страница 9: ... compensation adjusting cancelled in power off while starting the meter again will recover the normal cold junction compensation Press once Enter adjust manually and third display shows the cold junction compensation enable main display shows 0 C 32 F Press to move right one figure that adjusted Press to move left one figure that adjusted Press to add one figure upward that adjusted Press to minus...

Страница 10: ... types chosen Press to move left one figure that thermocouple types chosen T1 T2 exchange key Main secondary displays are exchanged T1 T2 measurement readings Look over key of the perpetual calendar Main display shows year secondary display shows month third display shows hour minute T1 T2 Press to enter C F C F T1 T2 T1 T2 7 ...

Страница 11: ...er setting record Need to set up INTV interval time 10 seconds Can increase the service time of order setting record press power key once Enter mode 1 of save electricity symbol will glimmer MCU will enter the sleep state will start MCU when the measurement recorded Press power key again finishes mode of save electricity 1 press power key for 2 seconds Enter mode 2 of save electricity symbol and R...

Страница 12: ...s key carry out clear memory function press key again get back to measuring state Back light Open close LCD back light will close automatically after opening one minute Function key of reset Take a cross screwdriver unlock after pressing Reset key under the battery cover the system will produce reset movement No press power key The system will be produced reset except 0 C of cold junction compensa...

Страница 13: ...ss once Confirms selection of the chosen function Press for 2 seconds Leaves set up function Press once to move right one figure of the set up function chosen Press once to move left one figure of the set up function chosen SET SET C F 10 SET SET SET SET SET SET SET SET SET SET SET SET SET SET C F C F C F C F C F C F ...

Страница 14: ...g Rel value set mode Set up compensation value of cold junction of 0 C of thermocouple Use and main display T1 or T2 thermocouple of the same type from main display T1 or T2 inputs 0 C 32 F temperature value adjust third display shows the cold junction compensating value enable main display shows 0 C 32 F Press key again to finish setting up third display shows the cold junction compensating value...

Страница 15: ... to 400 C 418 to 752 F 210 to 1000 C 346 to 1832 F 150 to 1300 C 238 to 2372 F J TYPE T TYPE E TYPE 0 to 1767 C 32 to 3212 F R S TYPE N TYPE Press to add one figure upward that adjusted Press to minus one figure downward that adjusted Press to move right one figure that adjusted Press to move left one figure that adjusted The sections set up of order setting record Divide into the sections of orde...

Страница 16: ... order setting scheduled Data Logging press and hold REC for 2 seconds Display will show REC START and CLOSE START or CLOSE will only appear during the section presently active When complete data can be viewed by using review mode on page 9 already full or to cancel the function of order setting repeated execution that will be incessant every day Press to add one figure upward that adjusted Press ...

Страница 17: ...t start time START that inquire the set up sections to press once will turn into stop time CLOSE Press once in stop time CLOSE the third display shows hour minute will turn into second At stop time CLOSE that inquire the set up sections to press once will turn into start time START Press once in start time START the third display shows hour minute will turn into second To delete the set up section...

Страница 18: ...e the above rule of setting up After finishing sections of set up order setting record after carrying out unless the capacity of memory has been already full or to cancel the function of order setting repeated execution that will be incessant every year Press to add one figure upward that adjusted Press to minus one figure downward that adjusted Press to move right one figure that adjusted When th...

Страница 19: ... the third display shows hour minute will turn into second At stop time CLOSE that inquire the set up sections to press once will turn into start time START Press once in start time START the third display shows hour minute will turn into second Set up interval time of record The interval time of record minimum interval time is one second the biggest interval time is 59 minutes and 59 seconds adju...

Страница 20: ...in positive negative indicator Overload indicator Positive overload show OL negative overload show OL Low power indicator When five sections of batteries mark show expressed battery power is run low Power 4 AAA batteries Auto power off The pressed key use has not reached 20 minutes the battery power will be turned off hold down key for 3 seconds to cancel auto power off function and mark of displa...

Страница 21: ...F K J T E N 2000 C F R S 1000 C 1832 F R S 1000 C 1832 F Accuracy K J T E N 0 05 reading 0 3 C 0 6 F below 100 C 148 F K J T E add 0 15 of reading N add 0 45 of reading R S 0 05 of reading 1 C 1 8 F Temperature coefficient 0 01 C of reading 0 03 C 0 06 F per F outside the specified 18 to 28 C 64 to 82 F range below 100 C 148 F K J T E add 0 04 of reading N reading add 0 08 of Temperature scale ITS...

Страница 22: ...19 NOTES ...

Страница 23: ...otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans...

Страница 24: ...tors 䡺 Turbine Paddlewheel Systems 䡺 Totalizers Batch Controllers pH CONDUCTIVITY 䡺 pH Electrodes Testers Accessories 䡺 Benchtop Laboratory Meters 䡺 Controllers Calibrators Simulators Pumps 䡺 Industrial pH Conductivity Equipment DATA ACQUISITION 䡺 Data Acquisition Engineering Software 䡺 Communications Based Acquisition Systems 䡺 Plug in Cards for Apple IBM Compatibles 䡺 Data Logging Systems 䡺 Reco...

Отзывы: