background image

For a product brochure please contact:

Timeguard Ltd. 

Victory Park, 400 Edgware Road,

London NW2 6ND  Tel: 020-8452-1112

or email [email protected]

A              Group company

67-058-323 (issue 2)

HELPLINE

020-8450-0515

or email [email protected]

For assistance with the product please contact:-

3 Year Guarantee

In the unlikely event of this product becoming 

faulty due to defective material or manufacture 

within 3 years of the date of purchase, please 

return it to your supplier in the first year with proof 

of purchase and it will be replaced free of charge. 

For years 2 and 3 or any difficulty in the first year 

telephone the helpline on

 

020 8450 0515.

NO

N

L

This unit is double insulated, and hence does 
not need connection to earth. If earth 
continuity is required, please use earth terminal 
on wall plate.

Fig. 4

Back Plate Removed

Alternative fixing holes

Mount the wall plate in this 

configuration only

Product retaining 

screws

Terminal for maintaining 
continuity of earth

4. Operation

Remove front cover using a cross point screwdriver 
to partially unscrew the cover securing screw at 
the top of the unit. Pull cover forwards, and away.

Use adjuster dial to set desired temperature.

Blue LED is lit when temperature is below 
desired value, indicating that the thermostat 
is calling for heat from the boiler. Once the 
room reaches the desired temperature the LED 
turns off and the TRT031/2 ceases to call for heat 
from the boiler.

The temperature swing can be adjusted between 
1°C and 0.5°C by selecting a jumper found on the 
rear of the unit (see Fig 2).

We suggest using the 0.5ºC position unless the 
boiler turns on and off too rapidly.

To reinstall the unit on the wall plate first 
ensure the wall plate retaining screws are 
loosened enough to clear the TRT031/2 body 
then engage the top of the TRT031/2 onto the 
wall plate retaining tabs (see Fig 4), and push 
firmly downwards and then inwards. There will 
be some resistance from the terminals. Once in 
place, secure with the retaining screws.

Restore mains to the unit after checking all 
system wiring is complete.

TRT031 shown

(TRT032 range 5 - 30ºC)

Tamper proof

cover

Operating & Installation Instructions

Electronic Frost 

Thermostat

Cat. No. TRT031

Electronic Room 

Thermostat

Cat. No. TRT032

Remove wall plate from unit, by undoing 
retaining screws (see Fig2), and pivoting the 
bottom of the unit outwards. The TRT031/2 
can then be lifted off.

Pass the incoming wires through the opening in 
wall plate, and fix wall plate securely to the wall, 
using screws (and wall plugs if necessary) provided. 
The screws which secure the product to the wall 
plate should be at the bottom (see Fig 2).

Allow sufficient excess cable to wire up the unit, 
but not too much to make it difficult to close 
the unit to the wall plate.

Connect the conductors to the relevant 
terminals, according to the wiring diagram on 
the wall plate (or Fig. 3 below). Ensure that the 
curved brass washer grips the conductor.

Fig. 3

N

NO

N

L

L

Wiring 
Diagram

5. Specifications

Current rating: 

6 (2) A

Voltage: 220-240V, 

50HZ

Switch type: 

Single pole, single throw 

 (SPST) 

Operating 
temperature range:  0 to 50°C

Set temperature 
range:  

5 to 10°C (TRT031)

 

5 to 30ºC (TRT032)

Complies with: 

BS EN 60730

Conforms to 
directives:  

73-23-EEC, 89-336-EEC

Temperature swing:  1°C or 0.5°C

Micro 
disconnection: 

Type 1.B control action

Proportional Control (PID) can also be selected 
on or off using a jumper on the rear of the unit 
(see Fig 2).

This can help in reducing temperature over-shoot. 
We suggest using the PID on position.

To clean use a clean dry cloth only. Do not use 
any liquid cleaners.

TRT031_TRT032_135x90_Instructions_iss_2b.indd   2

TRT031_TRT032_135x90_Instructions_iss_2b.indd   2

11/12/09   16:26:40

11/12/09   16:26:40

Summary of Contents for TRT031

Page 1: ...TRT031 shown TRT032 range 5 30ºC Tamper proof cover Electronic Frost Thermostat Cat No TRT031 Electronic Room Thermostat Cat No TRT032 t ...

Page 2: ...18ºC and then turn it up by one degree each day until you are comfortable with the temperature You won t have to adjust the thermostat further Any adjustment above this setting will waste energy and cost you more money If your heating system is a boiler with radiators there will usually be only one room thermostat to control the whole house But you can have different temperatures in individual roo...

Page 3: ...ould be mounted approximately 1 5 meters above floor level 3 Installation This product must be installed in accordance with the appropriate building and wiring regulations In all cases if there is a doubt as to how to proceed with an installation consult a qualified electrician your local authority s building control department or the Timeguard helpline 020 8450 0515 The TRT031 2 is designed to be...

Page 4: ...esistance from the terminals Once in place secure with the retaining screws Restore mains to the unit after checking all system wiring is complete Remove wall plate from unit by undoing retaining screws see Fig2 and pivoting the bottom of the unit outwards The TRT031 2 can then be lifted off Pass the incoming wires through the opening in wall plate and fix wall plate securely to the wall using scr...

Page 5: ...ikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge For years 2 and 3 or any difficulty in the first year telephone the helpline on 020 8450 0515 ...

Reviews: