background image

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords 

our customers the latest in technology and engineering.
OMEGA is a trademark of OMEGA ENGINEERING, INC.
© Copyright 2019 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, 

reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the 

prior written consent of OMEGA ENGINEERING, INC.

FOR 

WARRANTY

 RETURNS, please have the  

following information available BEFORE  

contacting OMEGA:
1.   Purchase Order number under which the

product was PURCHASED,

2.  Model and serial number of the product under 

warranty, and

3. Repair instructions and/or specific problems 

relative to the product.

FOR 

NON-WARRANTY

 REPAIRS, consult OMEGA 

for current repair charges. Have the following 

information available BEFORE contacting OMEGA:
1.  Purchase  Order  number  to  cover  the  COST 

 of the repair,

2. Model and serial number of the product, and
3. Repair instructions and/or specific problems 

relative to the product.

RETURN REQUESTS/INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. 

BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED 

RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID 

PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return 

package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent 

breakage in transit. 

 

WARRANTY/DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship 

for a period of 

13 months

 from date of purchase. OMEGA’s WARRANTY adds an additional one (1) 

month grace period to the normal 

one (1) year product warranty

 to cover handling and shipping 

time. This ensures that OMEGA’s customers receive maximum coverage on each product. 
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service 

Department will issue an Authorized Return (AR) number immediately upon phone or written request. 

Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no 

charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, 

including but not limited to mishandling, improper interfacing, operation outside of design limits,  

improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of  

having been tampered with or shows evidence of having been damaged as a 

result of excessive corrosion; or current, heat, moisture or vibration; improper 

specification; misapplication; misuse or other operating conditions outside of 

OMEGA’s control. Components in which wear is not warranted, include but are not  

limited to contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However,  

OMEGA neither assumes responsibility for any omissions or errors nor 

assumes liability for any damages that result from the use of its products 

in accordance with information provided by OMEGA, either verbal or 

written. OMEGA warrants only that the parts manufactured by it will be as 

specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR 

 

REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT 

THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF  

MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY 

DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are 

exclusive, and the total liability of OMEGA with respect to this order, whether 

based on contract, warranty, negligence, indemnification, strict liability or otherwise, 

shall not exceed the purchase price of the component upon which liability 

is based. In no event shall OMEGA be liable for consequential, incidental or special damages.

CONDITIONS:  Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a 

“Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) 

in medical applications or used on humans. Should any Product(s) be used in or with any nuclear 

installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes 

no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and, additionally, 

purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever 

arising out of the use of the Product(s) in such a manner.

Содержание FDT-25

Страница 1: ...TM User sGuide Shop online at e mail info omega com For latest product manuals omega com en us pdf manuals omega com omega com en us pdf manuals FDT 25 Ultrasonic Flowmeter...

Страница 2: ...r Service 1 800 622 2378 USA Canada only Engineering Service 1 800 872 9436 USA Canada only Tel 203 359 1660 Fax 203 359 7700 e mail info omega com omega com info omega com The information contained i...

Страница 3: ...ation 11 2 8TransducersInstallation 12 2 8 1TransducersSpacing 12 2 8 2V methodInstallation 12 2 8 3Z method Installation 13 2 8 4 W method Installation 13 2 8 5N methodInstallation 14 2 9Installation...

Страница 4: ...the OCT output 19 3 20 How to modify the built in calendar 19 3 21 How to adjust the LCD contrast 20 3 22 How to use the RS232 serial interface 20 3 23 How to view the Date Totalizers 20 3 24 How to...

Страница 5: ...ith power frequency transverter working nearby Other outstanding features the signal receiving circuits feature self adapting performance so as to ensure that the user can easily operate the instrumen...

Страница 6: ...nsverses the pipe twice or W method where the sound transverses the pipe four times or in Z method where the transducers are mounted on opposite sides of the pipe and the sound crosses the pipe once T...

Страница 7: ...er Top vierw stream transduer socket stream transduer socket Front view LCD DISPLAY LED Charging Indicator Keypad Bottom view Pins for battery recharge RS 232C communication interface Transducers STD...

Страница 8: ...r Cable 5m x2 Red Terminal 5m Red Terminal Blue Terminal Blue Terminal Extended Cable 5m x2 Optional Accessaries Red Terminal 5m Blue Terminal Red Terminal Blue Terminal Converted Terminal and AC DC A...

Страница 9: ...ion is provided to avoid inadvertent configuration changes or totalizer resets A time keeper is integrated in the flow meter for the index of date totalizing and works as the time base of flow accumul...

Страница 10: ...gurable Totalizer 7 digit totals for net positive and negative flow respectively Liquid Types Virtually all liquids Security Setup values Modification Lockout Access code needs unlocking Display 4x8 C...

Страница 11: ...is nearly consumed the battery voltage drops to below 3V The user can obtain an approximate battery working time from the battery voltage A software battery working time estimator is integrated in th...

Страница 12: ...rks as key when entering numbers Key is the going DOWN key when the user wants to go down sided menu window It also works as the key when entering numbers Key is backspace key when the user wants go l...

Страница 13: ...less steel which has a number 1 antecedent to stainless steel on the display the user should first press the ENT key to enter into a selection modification mode then either make the selection by press...

Страница 14: ...ipe materialsand standardliquids the followingdetailedstep by stepsetupis recommended 1 Press keys and then press 2 Press key press ENT key 1 1 to enter M11 window to input the digits for the pipe out...

Страница 15: ...s under M00 to M09 press the ENT key and the user will go to M90 press ENT key to return Press the dot key to go to M11 When the window display is under M25 press ENT key to go to M01 2 7 Transducers...

Страница 16: ...The measurement is realized by measuring the traveling time difference of the ultrasonic signals Since the difference is very small the spacing and the alignment of the transducers are critical facto...

Страница 17: ...used when the pipe diameter is between 300 millimeters and 500 millimeters TOP VIEW OF PIPE Upstream transducer SensorsSpacing Flow Downstream transducer 2 8 4 W method Installation W method is usuall...

Страница 18: ...r surface of the pipe and apply more coupler to increase the signal strength 3 Adjust the transducers both vertically and horizontally while checking the varying signal strength stop at the highest po...

Страница 19: ...stallation If the pipe parameters are entered correctly and the transducers are installed properly the value for this ratio should be in the range of 1003 If this range is exceeded the user should che...

Страница 20: ...RED transducers 3 3 How to change between units systems Use menu window M30 for the selection of unit system in English or Metric system 3 4 How to select a required flow rate unit Use menu window M3...

Страница 21: ...not affect the flow measurement when the actual flow is absolutely greater than the low cutoff value 3 11 How to setup a zero point There exists a Zero Point with certain installation which means the...

Страница 22: ...lly four parameters should be configured for the setups Enter the lower flow rate value in window M68 and the higher flow rate value in window M69 Enter the frequency range in window M67 For example a...

Страница 23: ...can be user configurable through M73 M74 M75 M76 For example assume that the Buzzer should start beeping when the flow rate is less than 300 m3 h and greater than 2000m3 h the following steps for set...

Страница 24: ...ion For example use it as a timer to show how long a fully charged battery will last Under M72 press ENT key and then select YES to reset the timer 3 25 How to use the manual totalizer Use M28 for the...

Страница 25: ...the allowed range of the value M12 Window for entering pipe wall thickness M13 Window for entering the inner diameter of the pipe M14 Window for selecting pipe material Standard pipe materials that t...

Страница 26: ...alue when poor signal condition occurs YES is the default setup M29 Enter a value ranging from 000 to 999 0 is the default value M30 Window for selecting unit system Default value is Metric The change...

Страница 27: ...n made M46 Network environment Identification Number Any integer can be entered except 13 0DH carriage return 10 0AH line feeding 42 2AH 38 65535 Every set of the instrument in a network environment s...

Страница 28: ...lue is entered M72 Working timer It can be cleared by pressing ENT key and then select YES M73 Enter Lower Flow Rate value that will trigger the 1 Alarm There are two virtual alarms in the system By v...

Страница 29: ...gram M95 Not used M96 Not used M97 Command to record the pipe parameters entered by the user either to the built in data logger or to RS 232C serial interface M98 Command to record the diagnostic info...

Страница 30: ...unter measures should be taken Error message causes Counter measures ROM Testing Error Segment Test Error Problemwith the software 1 Power on again 2 Contact with factory Stored Data Error The paramet...

Страница 31: ...signal detected 2 Transducers installed improperly 3 Too much fouling 4 The pipe liners are too thick 5 Problemwith transducers cords 1 Relocate measuring place 2 Clean the spot 3 Check the cords 4 Ch...

Страница 32: ...b Problem with transducer installation c Thereis a Zero Point Tryto zero theinstrument byusingM42 and make sure that the flow inside the pipe should be standstill 3 The battery can not work as long a...

Страница 33: ...format ending with a carriage CR and line feed LF Commonly used commands are listed in the following table Command Function Data Format DQD CR Return flow rate per day d ddddddE dd CR LF DQH CR Retur...

Страница 34: ...is a single byte value ranging 00 255 P Prefix before any command Command connector to make a longer command by combining up to 6 commands Notes CR stands for Carriage Return and LF for Line Feed d st...

Страница 35: ...mming much easier For example assume that the measurement of an instrument with IDN 4321 are going to be returned and then all the following 3 values 1 flow rate 2 velocity 3 POS totalizer will be ret...

Страница 36: ...y OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limite...

Страница 37: ...s M U Turbine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U...