8
Over Pressure Protection:
See table of Ranges and Resolutions.
Temperature Compensation
0°C to +50°C (32°F to +122°F) to rated accuracy
Note: For temperatures from –10 °C to 0 °C and 50 °C to 55 °C add
.005% F.S./°C
Standard Engineering Units
PSI, Bar, kg/cm2, inH
2
O (4°C, 20°C or 60°F),
ftH
2
O (4°C, 20°C or 60°F), cmH
2
O (4 °C and 20 °C), mH
2
O (4°C and
20°C), KPa, mBAR, inHg, mmHg, Torr
One custom unit (user programmable)
Media Compatibility
All ranges except 1 PSI and compound ranges:
Liquids and gases compatible with 316 stainless steel
1 PSI and compound ranges: clean, dry, non-corrosive gas
Environmental
Operating Temperature -10 °C to +55 °C
Storage -20 °C to +70 °C (-4 °F to +158 °F)
Humidity 10% to 95% RH Non-condensing
Pollution Degree II
Mechanical
Dimensions 4.5” (diameter) x 2.2” (depth) x 5” (height)
Pressure Connection: ¼” NPT Male
Housing: Stainless steel, meets NEMA 4/IP65
Display
5-1/2 Digits, 0.65” (16.53 mm) high
20-Segment bar graph, 0 to 100%
Power
Battery three (3), size AA alkaline batteries, optional 24 VDC power.
Battery Life 1,500 hours without backlight
2,000 hours at slow sample rate
Low Battery Indicator icon is displayed near the end of battery life