background image

WARRANTY/DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a
period of 

13 months

from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month

grace period to the normal 

one (1) year product warranty

to cover handling and shipping time. This

ensures that OMEGA’s customers receive maximum coverage on each product. 
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service
Department will issue an Authorized Return (AR) number immediately upon phone or written request.
Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no
charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser,
including but not limited to mishandling, improper interfacing, operation outside of design limits, 
improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of 
having been tampered with or shows evidence of having been damaged as a result of excessive corrosion;
or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating
conditions outside of OMEGA’s control. Components which wear are not warranted, including but not 
limited to contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However, 
OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any
damages that result from the use of its products in accordance with information provided by
OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be
as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR 
REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE,
AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND 
FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF 
LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of 
OMEGA with respect to this order, whether based on contract, warranty, negligence, 
indemnification, strict liability or otherwise, shall not exceed the purchase price of the 
component upon which liability is based. In no event shall OMEGA be liable for 
consequential, incidental or special damages.

CONDITIONS:  Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic
Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical
applications or used on humans. Should any Product(s) be used in or with any nuclear installation or
activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility
as set forth in our basic WARRANTY/ DISCLAIMER language, and, additionally, purchaser will indemnify
OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the
Product(s) in such a manner.

RETURN REQUESTS/INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE
RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN
(AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID
PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return
package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent
breakage in transit. 

FOR 

WARRANTY

RETURNS, please have the 

following information available BEFORE 
contacting OMEGA:
1. Purchase Order number under which the product

was PURCHASED,

2. Model and serial number of the product under

warranty, and

3. Repair instructions and/or specific problems 

relative to the product.

FOR 

NON-WARRANTY

REPAIRS, consult OMEGA

for current repair charges. Have the following
information available BEFORE contacting OMEGA:
1.  Purchase Order number to cover the COST 

of the repair,

2. Model and serial number of the product, and
3. Repair instructions and/or specific problems 

relative to the product.

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords
our customers the latest in technology and engineering.

OMEGA is a registered trademark of OMEGA ENGINEERING, INC.

© Copyright 2002 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the
prior written consent of OMEGA ENGINEERING, INC.

Содержание DPF78 SERIES

Страница 1: ...www omega com e mail info omega com User sGuide DPF75 DPF76 AND DPF78 SERIES Rate Totalizer Shop online at M1090 071603...

Страница 2: ...33 0 130 621 400 FAX 33 0 130 699 120 Toll Free in France 0800 4 06342 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany TEL 49 0 7056 9398 0 FAX 49 0 7056 9398 29...

Страница 3: ...E UNIT 13 SETTING THE RELAYS PRESETS 14 OUTPUT WIRING 15 ANALOG OUTPUT OPTION 16 RS232 RS422 SERIAL COMMUNICATIONS 17 RS232 RS422 WIRING 19 TROUBLESHOOTING GUIDE 20 UNPACKING Remove the Packing List a...

Страница 4: ...rate batch and grand total The PRE A PRE B keys allow you to see and set the relay trigger points The lock key allows you to lock and unlock the keypad functions by entering the lock out code The PRO...

Страница 5: ...unlock RELAYS STEP 5 DPF75 The DPF76 relays can only trigger on batch or total The DPF78 relays can only trigger on rate The DPF75 relays can be programmed to trigger on rate or total The relay setpoi...

Страница 6: ...ramming is accomplished by using the front panel in conjunction with rear dip switches Accuracy 50uA worst case Compliance Voltage 3 to 30 VDC non inductive RS232 RS422SERIAL INTERFACE If the serial i...

Страница 7: ...s than 125 of an inch thick the possibility exists that there will be some flexing Should this flexing occur the resulting deformation of the panel could cause a loss of the water tight seal In case t...

Страница 8: ...ably at the D C ground terminal of the unit 3 Output lines The unit has two relay outputs When these outputs are used to run external relays or solenoids spikes can be generated upon activation This n...

Страница 9: ...ons FTB600 Flow Meters Brown 1 COMMON 2 N O N C NPN 3 COMMON 4 N O N C NPN 5 A INPUT 6 B INPUT 7 11 to 19V 50mA OUT DC IN 8 DC GROUND 9 RESET INPUT 10 6 to 14V 50mA 11 A C INPUT 12 A C INPUT RELAYS A...

Страница 10: ...l is being displayed See below on how to modify for Batch Count and B as a Grand Total Counter MILLIVOLT INPUT OPTION JUMPER SELECTIONS OUTPUT JUMPER SELECTIONS FUNCTION A RELAY N C OUTPUT B RELAY N C...

Страница 11: ...LOWCHART NOTE Several programming selections will not appear with DPF76 and DPF78 units PRGM Press this key to step through menu choices ENTER RST Press this key to enter displayed value Start Here DP...

Страница 12: ...A B INPUTS ARE SEPARATE A B are not added or subtracted A SUB B A SUBTRACT B The number of scaled pulses from Input B are subtracted from the number of scaled pulses from Input A 99999 TO 999999 A AD...

Страница 13: ...reset A when in A NET B or A SEP B mode The relay will drop out when the rate of A falls below preset A A RELAY A DURATION This message will appear when A TOT is selected It is the duration which the...

Страница 14: ...readout Solution Enter a Factor of 10 and for every 10 pulses 1 will appear on the display Set rate per second minute or hour as desired A conveyor carrying bottles must be controlled for bottle speed...

Страница 15: ...TE only version Press the PRGM key to choose HIGH CPS 0 9 99KHz or LOW CPS 0 40Hz Press the ENTER key to enter the displayed choice This sets the decimal for factor B Press the arrow key under the dig...

Страница 16: ...imal location for the A B counters Press the arrow key under the desired digit location To clear the decimal press the arrow key furthest to the right Press the ENTER key to enter the displayed loca t...

Страница 17: ...ys under the desired digits to change Press ENTER to enter displayed value This sets the number of significant figures to be displayed Press the arrow key under the digit to change Press ENTER to ente...

Страница 18: ...ce After CODE flashes the display will show the existing lock code To change the code press the key under each digit to be changed Press ENTER to enter displayed value Key in the lock code see program...

Страница 19: ...This is the duration 1 to 99 9 sec that relay B will remain energized If 00 0 is selected the relay will latch until reset PRE A Preset A Final Preset The set point at which output A will trigger If t...

Страница 20: ...atch is complete or the rate has exceeded a set speed The outputs are programmable to be assigned for rate or count When assigned to the count the relays can have a user selectable on time duration or...

Страница 21: ...2 Select Count or Rate SW2 OFF down Analog output follows rate SW2 ON up Analog output follows count SWITCH 3 Select 4 20mA or 0 20mA SW3 OFF down Selects 4 20mA output range SW3 ON up Selects 0 20mA...

Страница 22: ...e is pressed PARITY Parity is a bit of information that is inserted before the stop bit and is used to help check if the transmission is correct When setting the parity you may select ODD parity bit i...

Страница 23: ...ssing the unit must be capable of driving all loads in the loop The input impedance of RS422 is much higher and there should be no problem driving as many as 99 units The transmit line remains in a hi...

Страница 24: ...PIN 7 STROBE PIN 6 12V PIN 7 BOTTOM BOARD A RST B C D E ENTER LOCK PRE A PRE B VIEW PRGM TRANSMIT PIN 2 GROUND PIN 5 RS 232 STROBE PIN 6 12V PIN 7 BOTTOM BOARD RS232 RS422 WIRING A RST B C D E ENTER...

Страница 25: ...the units with rate and total DPF75 When using a unit which has only count DPF76 or only rate DPF78 several menu items will not be displayed 1 Recheck power wiring 1 Use a different power supply or in...

Страница 26: ...21 NOTES...

Страница 27: ...22 NOTES...

Страница 28: ...23 NOTES...

Страница 29: ...shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA...

Страница 30: ...Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial pH...

Отзывы: