background image

 

FEATURES:

 

Data Storage for 125 samples 
Highly  accurate  single  input  thermometer  with  0.1% 
basic accuracy 
Large display for easy to read 
Robust protective Holster 
Thermocouple offset adjustment 
°C/°F selection 
MIN/MAX/HOLD functions 
Display backlight 
Auto-Power Off (APO) 
Auto-Range: 0.1/1° 
Wide  measuring  ranges  suitable  for  numerous  applica-
tions

INTRODUCTION

 

This  instrument  is  a  portable  3½  digit,  compact-sized 

digital thermometer designed to use external K type and J 
type  thermocouples.  It  also  has  the  feature  that  sensor 
offset can be adjusted for in the field. There are 2 inputs 
for  miniature  thermocouple  connectors  at  the  top  of  the 
instrument marked T1 and T2.

 

 

SAFETY INFORMATION 

It is recommended that you read the safety and opera-

tion instructions before using the thermometer. 

WARNING 

To avoid electrical shock, do not use this instrument 

when working voltages at the measurement surface 

over 24V AC or DC.

 

WARNING 

To avoid damage or burns, do not make temperature 

measurement in microwave ovens.

 

 

CAUTION

Repeated sharp flexing can break the thermocouple 

leads. To prolong lead life, avoid sharp bends in the 

leads, especially near the connector.

 

SPECIFICATIONS 

ELECTRICAL

Temperature Scale: 
Celsius or Fahrenheit user-selectable. 
Measurement Range: 
K-Type -100°C to 1372°C, (-150°F to 1999°F) 
J-Type -100°C to 1200°C, (-150°F to 1999°F) 
Resolution: 
1 degree or 0.1 degree from -59.9 to 199.9 degree °C or 
°F (auto ranging).
Accuracy:
Accuracy is specified for operating temperatures over the 
range  of  18°C  to  28°C  (64°F  to  82°F),  for  1  year,  not 
including thermocouple error.

 

±(0.1% rdg + 1°C) on °C,    ±(0.1% rdg + 2°F) on °F 

Temperature Coefficient: 
0.1 times the applicable accuracy specification per °C 
from 0°C to 18°C and 28°C to 50°C (32°F to 64°F and 
82°F to 122°F). 
Input Protection: 
24V dc or 24V ac rms maximum input voltage on any 
combination of input pins. 

Reading Rate: 1 time per second. 
Input Connector: 
Accepts standard miniature thermocouple connectors 
(flat blades spaced 7.9mm, center to center). 
 

ENVIRONMENTAL

Ambient Operating Ranges: 
0°C to 50°C (32°F to 122°F) <80% R.H. 
Storage Temperature: 
-20°C to 60°C (-4°F to 140°F) <70% R.H. 
 

GENERAL

Display: 
3½  digit  liquid  crystal  display  (LCD)  with  maximum 
reading of 1999. 
Overload: “-OL” is displayed. 
Battery: 
1.5Vx4pcs AAA size. 
Battery Life: 
150 hours typical with carbon zinc battery.
Auto Power Off: 
Approximately 20 minutes.
Dimensions: 
160mm(H) x 83mm(W) x 38mm(D). 

Weight: 230g. 
Supplied Thermocouples (2 per input):   
1 meter (40”) type K insulated beaded wire thermocouple. 
Maximum  insulation  temperature  is  482°C  (900°F). 
Thermocouple  accuracy  is  ±1.1°C  or  0.4%  of  reading 
(whichever is greater) from 0°C to 1250°C. 
 

OPERATING INSTRUCTIONS 

1. “ ” Power Button 

Press the “

 button to turn on or off thermometer. 

 

2. “ /°C/°F” Button 

Readings are displayed in either degrees Celsius(°C)  or 
degrees Fahrenheit(°F). When the thermometer is turned 
on, it is set to the  temperature scale that was in use when 
the thermometer  was  last  turned  off.  To  change  the 
temperature scale,  press the “°C/°F” button. 
 

3. “ / ” Button 

Press the “ ” button to turn on the backlight.   Press the 
“ ” button again to make the backlight  brighter and 
press “ ” button once more to turn off the  backlight. 
Backlight on  Brighter  Backlight off. 

HH801A

DUAL INPUT K/J DIGITAL THERMOMETER 

M4460/0711

Shop online at: omega.com e- mail: [email protected] 

For latest product manuals: omegamanual.info 

INSTRUCTION 

SHEET 

MADE IN TAIWAN

OMEGAnet On-Line Service

omega.com

Internet e-mail

[email protected]

Servicing North America:

U.S.A:

One Omega Drive, Box 4047
Stamford, CT 06907-0047

ISO 9001

Tel: (203) 359-1660

FAX: (203) 359-7700

Certified

e-mail: [email protected]

Canada:

976 Bergar
Laval (Quebec) H7L 5A1, Canada
Tel: (514) 856-6928

FAX: (514) 856-6886

e-mail: [email protected]

For immediate technical or application assistance:

U.S.A

Sales Service: 1-800-826-6342/1-800-TC-OMEGA

®

and

Customer Service: 1-800-622-2378/1-800-622-BEST

®

Canada:

Mexico:

En Espan ol: (001) 203-359-7803
e-mail: [email protected]
FAX: (001) 203-359-7807 [email protected]

Servicing Europe:

Benelux:

Postbus 8034, 1180 LA Amstelveen, The Netherlands
Tel: +31 (0)20 3472121

FAX: +31 (0)20 6434643

Toll Free in Benelux: 0800 0993344
e-mail: [email protected]

Czech

Frystatska 184, 733 01 Karviná, Czech Republic

Republic: Tel: +420 (0)59 6311899

FAX: +420 (0)59 6311114

Toll Free: 0800-1-66342

e-mail: [email protected]

France:

11, rue Jacques Cartier, 78280 Guyancourt, France
Tel: +33 (0)1 61 37 2900

FAX: +33 (0)1 30 57 5427

Toll Free in France: 0800 466 342
e-mail: [email protected]

Germany/ Daimlerstrasse 26, D-75392 Deckenpfronn, Germany

Austria:

Tel: + 49 (0)7056 9398-0

FAX: +49 (0)7056 9398-29

Toll Free in Germany: 0800 639 7678
e-mail: [email protected]

United

One Omega Drive, River Bend Technology Centre

Kingdom: Northbank, Irlam, Manchester

ISO 9002

M44 5BD United Kingdom

Certified

Tel: +44 (0)161 777 6611

FAX: +44 (0)161 777 6622

Toll Free in United Kingdom: 0800-488-488
e-mail: [email protected]

It is the policy of OMEGA Engineering, Inc. to comply with all

worldwide safety and EMC/EMI regulations that apply. OMEGA

is constantly pursuing certification of its products to the

European New Approach Directives. OMEGA will add the CE

mark to every appropriate device upon certification.

The information contained in this document is believed to be

correct, but OMEGA accepts no liability for any errors it

contains, and reserves the right to alter specifications without

notice.

These products are not designed for use in, and

should not be used for, human applications.

®

Отзывы: