background image

4. “ADJ/HOLD” Button 

Press the “HOLD” button to enter the Data Hold  mode, 
the  “HOLD”  annunciator  is  displayed  at  the  top  of  the 
display. 
When HOLD mode is selected,   the  thermometer  holds 
the present readings and stops all   further  measurements. 
Pressing the “HOLD” button again  cancels HOLD mode, 
causing the thermometer to resume measurement. 
 

5. “APO/TYPE” Button 

Press “TYPE” button to select the type of thermocouple 
“K” or “J”. Make sure the proper type has  been  selected. 
Pressing and holding down “APO” button for 2 seconds 
will turn on or off the APO(Automatic Power Off) mode, 
and the APO annunciator will appear or disappear on the 
display. Power is automatically turned off if no button is 
pressed for a period of time. 
 

6. “MAX MIN” Button

 

Press  “MAX  MIN”  button  to  enter  the  MAX  MIN  re-
cording  mode.  Press  “MAX  MIN”  button  to  cycle 
through  the  MAX,  MIN,  MAX-MIN  readings.  In  this 
mode, press “HOLD” button to stop recording, all values 
are  held,  press  again  to  resume  measurement.  In  this 
mode,  the  APO  function  and other  buttons  are  disabled, 
excluding “HOLD” and “ ” buttons. 
To prevent accidental loss of MAX, MIN and MAX-MIN, 
this mode can only be cancelled by pressing and holding 
down the “MAX MIN” button for 2 seconds to exit and 
clear readings. 
 

7. “CLR/READ” Button

 

Press “READ” button to enter READ Mode, the “READ” 
annunciator is displayed in the upper right corner. Press 
“ ”or “ ” button to review the recorded data. The LCD 
automatically  alternates  between  the  data  and  index.   
Press the “CLR” button and hold down for 2 seconds to 
clear the memory data. 
 

8. “REC” Button 

Up 125 data points can be recorded into memory.   
Press “REC” button once to record each data point. When 
the  data  is  recorded,  “REC”  is  displayed  in  the  upper 
right  corner.  If  the  memory  is  full,  data  will  not  be  re-
corded into the memory and “REC” will not be displayed. 
Data can be recorded again after the memory is cleared. 
 

9. “T1 T2/T1-T2/ ” Button 

Press  “T1”,  “T2”,  “T1-T2”  button  to  select  input  mode 
T1,  T2  or  T1-T2.  The  input  selection  indicates  which 
input  is  selected  for  display,  T1  thermocouple,  T2  ther-
mocouple or the differential between the two thermocou-
ples (T1-T2). 

ADJUST THERMOCOUPLE OFFSET

 

1. Insert the thermocouple into a known temperature (T) 

until the display stabilizes near the known temperature 
(T). 
example: ice point at 0°C or boiling water at 100°C 

2. Press and hold the “ADJ/HOLD” button for 2 seconds 

until the display starts to blink. 

3. Press “ ” or “ ” to adjust the displayed value. 
4. It can be adjusted ±6°F (±3°C) from default. If you can 

not adjust your reading to  match the known tempera-
ture (T),  please  check  your  T/C  type.  The  meter  may 
require calibration. 

5. Press “ENTER” button to confirm. 

OPERATOR MAINTENANCE 

WARNING 

To avoid possible electrical shock, disconnect the 

thermocouple connectors from the thermometer before 

removing the cover.

Battery Replacement 

1.  Power  is  supplied  by  4pcs  1.5V  (AAA  SIZE)  UM-4 

R03. 

2. The “

” appears on the LCD display when replace-

ment is needed. To replace battery remove screw from 
back of meter and lift off the battery cover. 

3. Remove the battery from battery contacts and replace. 
4. When not in use for long periods remove battery. 
5.  Do  not  store  in  locations  with  high  temperatures,  or 

high humidity. 

 

Cleaning 

Periodically wipe  the case with a damp cloth and deter-
gent, do not use abrasives or solvents. 

WARRANTY/DISCLAIMER

OMEGA  ENGINEERING,  INC.  warrants  this  unit  to  be  free  of  defects  in

materials  and  workmanship  for  a  period  of 

13  months

from  date  of

purchase.  OMEGA’s  WARRANTY  adds  an  additional  one  (1)  month  grace

period  to  the  normal 

one  (1)  year  product  warranty

to  cover  handling

and shipping time. This ensures that OMEGA’s customers receive maximum

coverage on each product. 

If  the  unit  malfunctions,  it  must  be  returned  to  the  factory  for  evaluation.

OMEGA’s Customer Service Department will issue an Authorized Return (AR)

number immediately upon phone or written request. Upon examination by

OMEGA, if the unit is found to be defective, it will be repaired or replaced at

no  charge.  OMEGA’s  WARRANTY  does  not  apply  to  defects  resulting  from

any  action  of  the  purchaser,  including  but  not  limited  to  mishandling,

improper interfacing, operation outside of design limits, improper repair, or

unauthorized  modification.  This  WARRANTY  is  VOID  if  the  unit  shows

evidence of having been tampered with or shows evidence of having been

damaged  as  a  result  of  excessive  corrosion;  or  current,  heat,  moisture  or

vibration; improper specification; misapplication; misuse or other operating

conditions  outside  of  OMEGA’s  control.  Components  in  which  wear  is  not

warranted, include but are not limited to contact points, fuses, and triacs.

OMEGA  is  pleased  to  offer  suggestions  on  the  use  of  its  various

products. However, OMEGA neither assumes responsibility for any

omissions  or  errors  nor  assumes  liability  for  any  damages  that

result from the use of its products in accordance with information

provided  by  OMEGA,  either  verbal  or  written.  OMEGA  warrants

only  that  the  parts  manufactured  by  the  company  will  be  as

specified  and  free  of  defects.  OMEGA  MAKES  NO  OTHER

WARRANTIES  OR  REPRESENTATIONS  OF  ANY  KIND

WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE,

AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF

MERCHANTABILITY  AND  FITNESS  FOR  A  PARTICULAR  PURPOSE

ARE  HEREBY  DISCLAIMED.  LIMITATION  OF  LIABILITY:  The

remedies of purchaser set forth herein are exclusive, and the total

liability  of  OMEGA  with  respect  to  this  order,  whether  based  on

contract,  warranty,  negligence,  indemnification,  strict  liability  or

otherwise, shall not exceed the purchase price of the component

upon  which  liability  is  based.  In  no  event  shall  OMEGA  be  liable

for consequential, incidental or special damages.

CONDITIONS:  Equipment sold by OMEGA is not intended to be used, nor

shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in

or with any nuclear installation or activity; or (2) in medical applications or

used  on  humans.  Should  any  Product(s)  be  used  in  or  with  any  nuclear

installation or activity, medical application, used on humans, or misused in

any  way,  OMEGA  assumes  no  responsibility  as  set  forth  in  our  basic

WARRANTY / DISCLAIMER  language,  and,  additionally,  purchaser  will

indemnify OMEGA and hold OMEGA harmless from any liability or damage

whatsoever arising out of the use of the Product(s) in such a manner.

RETURN REQUESTS / INQUIRIES

Direct  all  warranty  and  repair  requests/inquiries  to  the  OMEGA  Customer

Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA,

PURCHASER  MUST  OBTAIN  AN  AUTHORIZED  RETURN  (AR)  NUMBER

FROM  OMEGA’S  CUSTOMER  SERVICE  DEPARTMENT  (IN  ORDER  TO

AVOID  PROCESSING  DELAYS).  The  assigned  AR  number  should  then  be

marked on the outside of the return package and on any correspondence.

The  purchaser  is  responsible  for  shipping  charges,  freight,  insurance  and

proper packaging to prevent breakage in transit.  

FOR 

WARRANTY

RETURNS, please

have the following information

available BEFORE contacting

OMEGA:

1. Purchase Order number under

which the product was

PURCHASED,

2. Model and serial number of the

product under warranty, and

3. Repair instructions and/or specific 

problems relative to the product.

FOR 

NON-WARRANTY

REPAIRS,

consult OMEGA for current repair

charges. Have the following

information available BEFORE

contacting OMEGA:

1. Purchase Order number to cover

the COST of the repair,

2. Model and serial number of the

product, and

3. Repair instructions and/or specific

problems relative to the product.

OMEGA’s policy is to make running changes, not model changes, whenever

an improvement is possible. This affords our customers the latest in

technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2011 OMEGA ENGINEERING, INC. All rights reserved. This

document may not be copied, photocopied, reproduced, translated, or

reduced to any electronic medium or machine-readable form, in whole or

in part, without the prior written consent of OMEGA ENGINEERING, INC.

Where Do I Find Everything I Need for

Process Measurement and Control?

OMEGA…Of Course!

Shop online at omega.com

TEMPERATURE

Thermocouple, RTD & Thermistor Probes, 

Connectors, Panels & Assemblies

Wire: Thermocouple, RTD & Thermistor

Calibrators & Ice Point References

Recorders, Controllers & Process Monitors

Infrared Pyrometers

PRESSURE, STRAIN AND FORCE

Transducers & Strain Gages

Load Cells & Pressure Gages

Displacement Transducers

Instrumentation & Accessories

FLOW/LEVEL

Rotameters, Gas Mass Flowmeters & Flow Computers

Air Velocity Indicators

Turbine/Paddlewheel Systems

Totalizers & Batch Controllers

pH/CONDUCTIVITY

pH Electrodes, Testers & Accessories

Benchtop/Laboratory Meters

Controllers, Calibrators, Simulators & Pumps

Industrial pH & Conductivity Equipment

DATA ACQUISITION

Data Acquisition & Engineering Software

Communications-Based Acquisition Systems

Plug-in Cards for Apple, IBM & Compatibles

Data Logging Systems

Recorders, Printers & Plotters

HEATERS

Heating Cable

Cartridge & Strip Heaters

Immersion & Band Heaters

Flexible Heaters

Laboratory Heaters

ENVIRONMENTAL MONITORING AND CONTROL

Metering & Control Instrumentation

Refractometers

Pumps & Tubing

Air, Soil & Water Monitors

Industrial Water & Wastewater Treatment

pH, Conductivity & Dissolved Oxygen Instruments

Отзывы: