background image

omega altise 

6

 

 
 
AIR-CONDITIONING WITH INSTALLATION 
 
If required, your appliance can also be installed semi- 
permanently (Fig. 5). 
Proceed as follows: 
Drill in an outside wall or in the window pane a 134mm dia. 
hole respecting the heights shown in (Fig. 6). 
 

 
 
 
 

 

Fit the flange accessory provided in the hole following 
the indications in figs. 7, 8 and 9. 

 

Fit the hose in the housing at the back of the appliance 
(Fig.1). 

 

Fit the end of the hose to the flange as shown in (Fig. 6). 
When the hose is not fitted, the hole can be closed with 
the flange cap. 
 

Keep the air hose as short and free of curves as possible 
to avoid bottlenecks. 
 

 

When installing the air conditioner semi-permanently,   

you should leave a door slightly open (as little as 1cm) to        
guarantee correct ventilation. 

 

 
 
 
 
 

Содержание APC12CVA

Страница 1: ...Instruction Manual APC12CVA APC12RCVA APC14CVA OAPC14RCVA Portable Type Air Conditioner ...

Страница 2: ...cription of the control panel 7 Operating from the control panel 7 Description of the remote control 10 Correct use 10 Using the remote control unit 11 Self diagnosis 13 Tips for correct use 14 Cleaning 15 Start end of season operations 15 Troubleshooting 16 Technical specifications 17 ...

Страница 3: ... efficient earth system Have your electrical circuit checked by a qualified technician Do not use extension cables Before cleaning or maintenance always unplug the appliance from the mains socket Never unplug the appliance by pulling on the power cable Do not install the appliance in rooms containing gas oil or sulphur Do not install near sources of heat Keep the appliance at least 50cm away from ...

Страница 4: ...e indicated on the rating plate on the back of the appliance The power socket and electrical circuit are adequate for the appliance The mains socket matches the plug If this is not the case have the plug replaced The mains socket is adequately earthed Failure to follow these important safety instructions absolves the manufacturer of all liability ...

Страница 5: ...rol panel 3 Castors 4 Handles 5 Remote control receiver 6 Filter 7 Intake grille 8 Air exhaust hose housing 9 Condensate drain 10 Power cable 11 Air exhaust hose 12 Window outlet 13 Suckers 14 Remote control 15 Castor locks 16 Window bracket 17 Drain pan ...

Страница 6: ...near a window or French window Adjust the length of the hose to reach the window Make sure the air exhaust hose is unobstructed Open the window or French window slightly and position the outlet Fig 2 If you have a sash window place the bracket on the window sill extend the bracket fully within the window frame fix the bracket by using the pin then lower the window onto the bracket Insert the windo...

Страница 7: ...ovided in the hole following the indications in figs 7 8 and 9 Fit the hose in the housing at the back of the appliance Fig 1 Fit the end of the hose to the flange as shown in Fig 6 When the hose is not fitted the hole can be closed with the flange cap Keep the air hose as short and free of curves as possible to avoid bottlenecks When installing the air conditioner semi permanently you should leav...

Страница 8: ...display indicating that the appliance is in standby Press the button until the appliance comes on The last function active when it was turned off will appear 1 Cool symbol 2 Dry symbol 3 Fan symbol 4 HEAT symbol On Reverse cycle models only 5 SMART symbol 6 POWERFUL symbol 7 Temperature indicator 8 Timer symbol 9 Alarm symbol 10 Speed indicator 11 AUTO FAN indicator 12 Sleep symbol 13 MODE button ...

Страница 9: ...l display The most suitable temperature for the room during the summer varies from 24 C to 27 C You are recommended however not to set a te mperature much below the outdoor temperature DRY MODE Ideal to reduce room humidity spring and autumn damp rooms rainy periods etc In dry mode the appliance should be prepared in the same way as for cool mode with the air exhaust hose attached to enable the mo...

Страница 10: ...k in place When the tank has been emptied the appliance starts up again N B When operating in very cold rooms the appliance defreezes automatically momentarily interrupting normal operation appears on the display During this operation it is normal for the noise made by the appliance to change in this mode you may have to wait for a few minutes before the appliance starts giving out hot air in this...

Страница 11: ...time button 11 ON OFF button 12 MODE button selects the modes 13 FAN button 14 POWERFUL button 15 SWING button 16 TIMER button 17 SLEEP button 18 Reset button resets the factory default setting CORRECT USE Point the remote control at the receiver on the appliance The remote control must be no than 7 metres away from the appliance without obstacles between the remote control and the receiver The re...

Страница 12: ...pen USING THE REMOTE CONTROL UNIT The first part of the controls on the remote control are the same as those on the control panel of the appliance You should therefore refer to the instruction in the chapter operating from the control panel to turn the appliance on and select the operating mode COOL DRY FAN HEAT reverse cycle models only or SMART and the fan speed The following section describes t...

Страница 13: ...fan or smart as described above Press the SWING button The appliance operates in the previously selected mode the message appears on the remote control to indicate the swing is active Press the swing button again the message disappears to indicate the swing has stopped Programming start up Press the TIMER button once The message flashes on the remote control display Press the MODE button to set th...

Страница 14: ... When that time is reached press the TIMER button to confirm The message hr DELAY appears on the remote control display and the symbol is displayed on the appliance to indicate that the timer is active To cancel the timer setting press the TIMER button again anytime during the set time SELF DIAGNOSIS The appliance has a self diagnosis system to identify a number of malfunctions Error messages are ...

Страница 15: ... room from direct exposure to the sun by partially closing curtains and or blinds to make the appliance much more economical to run Fig 23 Never rest objects of any kind on the air conditioner Do not obstruct the air intake and outlet Fig 24 Leave the grilles free Make sure there are no heat sources in the room Never use the appliance in very damp rooms laundries for example Never use the applianc...

Страница 16: ...ilter every week of operation The filters are housed in the intake grille Fig 25 Use a vacuum cleaner to remove dust accumulations from the filter If it is very dirty immerse in warm water and rinse a number of times The water should never be hotter than 40 C After washing leave the filter to dry then a ttach the intake grille to the appliance START END OF SEASON OPERATIONS START OF SEASON CHECKS ...

Страница 17: ...ove Eliminate the heat sources Fit the air exhaust hose in the housing at the back of the appliance Fig 1 Clean the filter as described above Wait This delay is part of nor mal operation See the SELF DIAGNOSIS chapter There is no current It is not plugged into the mains The internal safety device has tripped There are bends in the air exhaust hose Something is preventing the air from being dischar...

Страница 18: ...vertent resetting of the thermal cut out this appliance must not be supplied through an external switching device such as a time or connected to a circuit that is regularly switched on and off by the utility Omega Altise products are distributed in Australia by Hagemeyer Appliances A Division of Hagemeyer Brands Australia Pty Ltd ABN 28 001 375 686 Locked Bag 4013 Kingsgrove NSW 2208 Phone 1300 73...

Отзывы: