20160

602

 

Installation 

 
1) 

 

2) 

 

Connecting several condensate collecting points to one condensate drain device causes operating 
problems (1). Make sure that each condensate collecting point has its own condensate drain (2). 
After installation or maintenance, the test button should be pressed to empty condensate that has 
been collected while the ball valve has been closed. 

Electrical installation 

 

Recommended wire lengths (mm) 

 

 

 

 

230V/115V 

24Vdc 

Neutral  

+24Vdc 

Line 

0V 

Protective Earth 

 

 

Electrical connection should be made as shown above. It depends on orientation of the cover. 
Be careful not to pinch wires by cover! 
Be careful to clamp all strains of wires into respective terminal blocks (use ferrules)! 
 

Содержание TDM16M

Страница 1: ...instructions carefully before installing the product Trouble free and safe operating of the product can only be guaranteed if recommendations and conditions stated in this manual are respected 201606...

Страница 2: ...strainer TD 16M 115Vac 16 bar 3400394 4700319 4700318 3400821 TD 16M 230Vac 16 bar 3400395 4700317 TD 25M 115Vac 25 bar 3400479 4700338 TD 25M 230Vac 25 bar 3400480 4700339 TD 50M 115Vac 50 bar 340095...

Страница 3: ...ng yours specific TDxxM series application Type TD 16M TD 25M TD 50M TD 150M TD 400M TD16Mcr Operating medium Air water oil Aggressive fluids Voltage 115 Vac 115 V 10 50 60 Hz 230 Vac 230 V 10 50 60 H...

Страница 4: ...Do not exceed maximal operating pressure or operating temperature range see data label Do not use the device in hazardous areas with potentially explosive atmospheres Use original spare parts only Us...

Страница 5: ...e the test button should be pressed to empty condensate that has been collected while the ball valve has been closed Electrical installation Recommended wire lengths mm 230V 115V 24Vdc 1 Neutral 24Vdc...

Страница 6: ...n LED light is turned on until the time Toff passes when new cycle begins Cycles repeats continuously The time between discharges Toff can be set from 1 2 to 45 minutes The time of discharge Ton can b...

Страница 7: ...nds on various operating parameters such as pressure temperature dirt content etc Attention Before beginning maintenance work follow these steps 1 Close ball valve 2 Depressurize the unit push test bu...

Страница 8: ...nit was operated when it was clearly defective Non original spare parts or replacement parts were used The unit was not operated within the permissible technical parameters Unauthorized constructional...

Отзывы: