3
20160
602
Technical data
1
Power depends on coil used
2
Elbow external thread
3
Strainer max working pressure is 50 bar
APPROXIMATE CALCULATION OF DISCHARGE CAPACITY
𝑄[l/min] = 𝐾
𝑉𝑆
[l/min] ∙ √
𝑝[bar]
1 bar
∙ (
𝑇
𝑂𝑁
[s]
𝑇
𝑂𝑁
[s] + 𝑇
𝑂𝐹𝐹
[min] ∙ 60
)
Q
[l/min]
Discharge capacity
K
VS
[l/min]
Flow coefficient of valve for water/ condensate
p
[bar]
Pressure drop across valve (It equals to system pressure in case
of condensate drains.)
T
ON
[0.5 s – 10 s]
Duration of one discharge of condensate
T
OFF
[0.5 min – 45 min] Period between discharges of condensate
Please take the relevant climate zone into account when dimensioning yours specific
TDxxM series application.
Type
TD 16M
TD 25M
TD 50M
TD 150M
TD 400M
TD16Mcr
Operating medium
Air, water, oil
Aggressive
fluids
Voltage
115 Vac
115 V ±10%, 50 – 60 Hz
230 Vac
230 V ±10%, 50 – 60 Hz
24 Vdc
24 Vdc
Power interface
3 x 0,75mm
2
Power
(1)
115 Vac
max. 18 VA
230 Vac
max. 18 VA
24 Vdc
max. 22 W
Operating temperature range
1,5 – 65°C
Protection class
IP65
Operation pressure range
0 – 16 bar
0 – 232 psi
0 – 25 bar
0 – 362 psi
0 – 50bar
0 – 735psi
0 – 150 bar
0 – 2175 psi
0 – 400 bar
0 – 5800 psi
0 – 16 bar
0 – 232 psi
K
VS
2,4 l/min
1,5 l/min
0,7 l/min
0,7 l/min
0,3 l/min
3,4 l/min
Inlet connection
R 1/2"
R 1/2"
R 1/2"
Rp 1/4"
G 1/2"
(2)
Rp 1/4"
Strainer
Yes
Yes
Yes
No
(3)
No
No
Outlet connection
Rp 1/4"
Rp 1/4"
Rp 1/4"
Rp 1/4"
G 1/4"
Rp 1/4"
Mass
510 g
510 g
580 g
380 g
560g
460 g