CORRECTION FACTORS
To calculate the correct capacity of a given adsorber based on actual operating conditions, multiply the
nominal flow capacity by the appropriate correction factor(s).
CORRECTED CAPACITY = NOMINAL FLOW CAPACITY x C
OP
OPERATING PRESSURE
OPERATING TEMPERATURE
PRESSURE EQUIPMENT DIRECTIVE PED 2014/68/EU (Fluid group 2)
TACm 6 - 70
Category 1, Module A
TACm 105
Category 2, Module H
There is Technical datasheet available. For additional technical specification, contact
manufacturer.
Safety instructions
The relevant safety at work and accident prevention regulations, plus operating instructions,
shall apply for operating the tower. The tower has been constructed in accordance with the
generally recognized rules of engineering. It complies with the requirements of directive
2014/68/EU concerning pressure equipment.
Ensure that installation complies with local laws for operation and routine testing of
pressure equipment at the place of installation.
Operator/user of the tower should make himself familiar with the function, installation and
start-up of the unit. All the safety information is always intended to ensure your personal
safety.
[bar]
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
[psi]
29
44
58
72
87
100
115
130
145
160
174
189
203
218
232
C
OP
0,38
0,5
0,63 0,75 0,88
1
1,13 1,25 1,38 1,50 1,63 1,75 1,88 2,00 2,13
[bar]
20
25
30
35
40
45
50
55
60
C
OT
1
0,98 0,97 0,92 0,86 0,75 0,60
-
-