AWS Installation and operating manual
www.omega-air.si
7
OMEGA AIR d.o.o., Ljubljana (o)
Model:
(1)
Ser. number:
(2)
Production year:
(3)
Max pressure. (Bar):
(4)
Flow capacity (l/min): (5)
Electric current (A):
(7)
Voltage (V):
(9)
Motor power (kW): (8)
Mass (kg):
(6)
After the checks, plug the equipment in and turn it on by switching the pressure switch to
ON – 1 (With three-phased motors check also the rotation of the motor). To turn the motor
off, just switch the button on the pressure switch to OFF – 0 (picture 6).
Picture 4: Ideal oil level
Picture 5: Condensate drain
Picture 6: pressure switch
ATTENTION!
To improve the start-up of the compressor, a pressure switch is added,
with a release valve. The valve stays open until the inner pressure does
not reach about 1 bar. At this value the valve closes. This enables the motor to
immediately reach normal rotations and guarantees an optimal start-up even in
cold weather or tensions under the normal level.
To turn off the compressor, always use the button on the pressure switch. If you pull out the
plug, the compressor head will not release pressure, which might cause problems at the next
start-up of the equipment. The compressor is otherwise meant to work under low
temperatures, although in such cases it is required to monitor possible freezing of the
condensate in the system.
Compressor information
With each contact with the manufacturer (ordering spare parts, service…) use the
information, provided by the label, attached to the front site of the documentation and the
bottom of the compressor aggregate. All other information about the compressor you can
get in this manual.