![Omcan VP-NL-0040-MS Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/omcan/vp-nl-0040-ms/vp-nl-0040-ms_instruction-manual_4168692008.webp)
8
Installation
Operation
• The models with the option Gas/MAP are standard equipped with a compressed air inlet.
•
Extra sealing pressure is not necessary and not available for the Table-Top models.
•
Consult your dealer for installation details.
• Maximum pressure: 1 bar.
• Assure a good connection and use high-quality materials.
TEN-PROGRAM CONTROL SYSTEM
In addition to vacuum and sealing times, machines with a Ten-Program control system may be programmed for
several additional functions. Each of the 9 customizable programs is either:
1. Time-controlled.
2. Sensor-controlled
TIME-BASED OPERATION (VACUUM GAUGE: MBAR)
•
The values for vacuum and sealing time, as well as the values for several optional functions, are selected
by the customer and saved in any of 9 customizable programs P1-9.
• When operating a packaging machine with a time-based program, the actual vacuum pressure is indicated
by the analog vacuum gauge. The number of seconds of vacuum time remaining is shown on the LCD
display.
PLUG & PLAY
• When turning on a time-based machine for the first time, it will start up in the PA program. This is a pre-set
factory program with 30-40 seconds vacuum time and 2 seconds of sealing time.
• When turning on the machine after that, it will start up in the most-recently used program.
OPTIONAL INSTALLATION OF A SENSOR OR SOFT-AIR
•
A machine with a time-based control program can be upgraded to sensor-based operation at a later date
by installing the optional sensor kit.
•
The Soft-Air feature can also be installed at a later date by ordering the optional soft-air kit.
SENSOR-BASED OPERATION (DIGITAL DISPLAY: MBAR)
• When operating a packaging machine with a sensor-based program, the actual vacuum pressure is digitally
shown on the LCD display in mbar (standard setting) or in % vacuum.
PLUG & PLAY
• When turning on a sensor-based machine for the first time, it will start up in the PA program. This is a pre-
set factory program with 5 mbar of vacuum and 2 seconds of sealing time.
• When turning on the machine after that, it will start up in the most-recently used program.