background image

7

Installation and Operation

To ensure that your unit works properly from the first day, it must be installed properly. We highly recommend a 

trained refrigeration mechanic and electrician install your equipment.

•  Remove the outer packaging, Inspect for concealed damage. Again, immediately file a claim with the freight 

carrier if there is damage.

• 

Remove the wood frame and pallet.

•  Place the refrigerator on a flat surface and remove to the final location. Be sure there is adequate 

ventilation in your room. Under extreme heat conditions, (100°F+, 38°C+), you may want to install an 

exhaust fan.

ELECTRICAL

Do not under any circumstances cut or remove the grounding prong from the power cord. For safety this 

appliance must be properly grounded at all times.

•  The power cord of this cooler is equipped with a grounding plug which mates with a standard grounding 

wall outlet to minimize the possibility of electric shock hazard.

•  If the outlet is a standard 2-prong outlet, it must be replaced with the properly grounded wall outlet. NEVER 

USE AN ADAPTER PLUG!

•  Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly 

grounded. Check the incoming voltage with a voltmeter.

Technical Specifications

Model

RS-CN-0120-B

RS-CN-0120-S

RS-CN-0200-B

RS-CN-0200-S

Type

Black

Stainless Steel

Black

Stainless Steel

Temperature 

Range

0 - 6ºC / 32 - 43ºF

Max Ambient Temp 

Rating

32ºC / 90ºF

Power

1/4+ HP

3/4 HP

Electrical

115V / 60Hz / 1

Current

2.6A

5.9A

Capacity

508 L / 18 cu.ft.

903 L / 32 cu.ft.

Refrigerant

R290

Dimensions

47” x 32.5” x 43” / 1200 x 825 x 1089mm

82” x 32.5” x 43” / 2082 x 825 x 1089mm

Packaging 

Dimensions

52” x 37” x 49” / 1320 x 940 x 1240mm

86.8” x 37” x 49” / 2202 x 940 x 1240mm

Weight

319 lbs. / 145 kgs.

506 lbs. / 230 kgs.

Packaging Weight

429 lbs. / 195 kgs.

638 lbs. / 290 kgs.

Item Number

50077

50079

50078

50080

Содержание RS-CN-0120-B

Страница 1: ...d 01 29 2021 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Refrigerated Showcases Models RS CN 0120 B 0200 B 0120 S 0200 S Items 50077 50078 50079 50080 Instruction M...

Страница 2: ...on Disclaimer General Information Safety and Warranty Technical Specifications Installation and Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Warranty Registration Model...

Страница 3: ...NOT RESPONSIBLE FOR ANY DAMAGES DUE TO WATER LEAKS WARRANTY FOR WATER LEAKS IS VOID IF THE AMBIENT ROOM TEMPERATURE EXCEEDS 75 F AND 55 RELATIVE HUMIDITY AND THE APPLIANCE DRAIN IS NOT CONNECTED DIRE...

Страница 4: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Страница 5: ...ol y que este ha sido entrenado en el correcto funcionamiento de esta m quina y sta usando ropa apropiada y autorizada Cualquier modificaci n a la m quina an la la garant a y puede causar da os a las...

Страница 6: ...ation Unit should be placed far from any heating source to avoid decrease of refrigeration efficiency Install the refrigerator in a dry place to prevent rust from forming on the compartment body which...

Страница 7: ...lug which mates with a standard grounding wall outlet to minimize the possibility of electric shock hazard If the outlet is a standard 2 prong outlet it must be replaced with the properly grounded wal...

Страница 8: ...lead to service difficulties Should it ever become necessary to replace the temperature control it should be ordered from your dealer or recommended service agent LIGHT SWITCH LOCATION The light switc...

Страница 9: ...Impression is for stubborn stains and discoloration Rub in direction of polish lines Easy off and De Grease It oven aid are excellent for removals on all finishes for grease fatty acids blood and bur...

Страница 10: ...tional cleaners are loaded with chlorides the industry is providing an ever increasing choice of non chloride cleaners If unsure of chloride content contact the cleaner supplier If present cleaner con...

Страница 11: ...temperature is too warm Thermostat set too warm Set thermostat to lower temperature Blocking air flow Re arrange product to allow for proper air flow Make sure there is at least four inches of cleara...

Страница 12: ...12 Parts Breakdown Model RS CN 0120 B 50077 Model RS CN 0120 S 50079...

Страница 13: ...135 Power Cord for 50077 26 AB659 Support Holder of Cabinet for 50077 45 AB638 Fixed Board of Curve Glass for 50077 9 AE984 Thermostat Installation Cover for 50077 27 AB660 Cover Board of Machine Room...

Страница 14: ...135 Power Cord for 50079 26 AB659 Support Holder of Cabinet for 50079 45 AB638 Fixed Board of Curve Glass for 50079 9 AE984 Thermostat Installation Cover for 50079 27 AB660 Cover Board of Machine Room...

Страница 15: ...15 Parts Breakdown Model RS CN 0200 B 50078 Model RS CN 0200 S 50080...

Страница 16: ...A249 Condenser Fan Motor Cover for 50078 45 AB762 Fixed Board of Curve Glass for 50078 9 AB604 Sealing Rubber Strip for 50078 27 AB657 Left Track of Installation Board for 50078 46 AB763 Curve Glass f...

Страница 17: ...A249 Condenser Fan Motor Cover for 50080 45 AB762 Fixed Board of Curve Glass for 50080 9 AB604 Sealing Rubber Strip for 50080 27 AB657 Left Track of Installation Board for 50080 46 AB763 Curve Glass f...

Страница 18: ...18 Electrical Schematics Model RS CN 0120 B 50077 Model RS CN 0200 B 50078 Model RS CN 0120 S 50079 Model RS CN 0200 S 50080...

Страница 19: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Страница 20: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Отзывы: