7
Installation and Operation
To ensure that your unit works properly from the first day, it must be installed properly. We highly recommend a
trained refrigeration mechanic and electrician install your equipment.
• Remove the outer packaging, Inspect for concealed damage. Again, immediately file a claim with the freight
carrier if there is damage.
•
Remove the wood frame and pallet.
• Place the refrigerator on a flat surface and remove to the final location. Be sure there is adequate
ventilation in your room. Under extreme heat conditions, (100°F+, 38°C+), you may want to install an
exhaust fan.
ELECTRICAL
Do not under any circumstances cut or remove the grounding prong from the power cord. For safety this
appliance must be properly grounded at all times.
• The power cord of this cooler is equipped with a grounding plug which mates with a standard grounding
wall outlet to minimize the possibility of electric shock hazard.
• If the outlet is a standard 2-prong outlet, it must be replaced with the properly grounded wall outlet. NEVER
USE AN ADAPTER PLUG!
• Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly
grounded. Check the incoming voltage with a voltmeter.
Technical Specifications
Model
RS-CN-0120-B
RS-CN-0120-S
RS-CN-0200-B
RS-CN-0200-S
Type
Black
Stainless Steel
Black
Stainless Steel
Temperature
Range
0 - 6ºC / 32 - 43ºF
Max Ambient Temp
Rating
32ºC / 90ºF
Power
1/4+ HP
3/4 HP
Electrical
115V / 60Hz / 1
Current
2.6A
5.9A
Capacity
508 L / 18 cu.ft.
903 L / 32 cu.ft.
Refrigerant
R290
Dimensions
47” x 32.5” x 43” / 1200 x 825 x 1089mm
82” x 32.5” x 43” / 2082 x 825 x 1089mm
Packaging
Dimensions
52” x 37” x 49” / 1320 x 940 x 1240mm
86.8” x 37” x 49” / 2202 x 940 x 1240mm
Weight
319 lbs. / 145 kgs.
506 lbs. / 230 kgs.
Packaging Weight
429 lbs. / 195 kgs.
638 lbs. / 290 kgs.
Item Number
50077
50079
50078
50080