General Information

Omcan Manufacturing and Distributing Company Inc., Food Machinery of America, Inc. dba Omcan 

and Omcan Inc. are not responsible for any harm or injury caused due to any person’s improper or 

negligent use of this equipment. The product shall only be operated by someone over the age of 18, of 

sound mind, and not under the influence of any drugs or alcohol, who has been trained in the correct 

operation of this machine, and is wearing authorized, proper safety clothing. Any modification to the 

machine voids any warranty, and may cause harm to individuals using the machine or in the vicinity of 

the machine while in operation.

CHECK PACKAGE UPON ARRIVAL

Upon receipt of an Omcan shipment please inspect for external damage. If no damage is evident on the 

external packaging, open carton to ensure all ordered items are within the box, and there is no concealed 

damage to the machine. If the package has suffered rough handling, bumps or damage (visible or concealed), 

please note it on the bill of lading before accepting the delivery and contact Omcan within 24 hours, so we may 

initiate a claim with the carrier. A detailed report on the extent of the damage caused to the machine must be 

filled out within three days, from the delivery date shown in the shipping documents. Omcan has no recourse 

for damaged products that were shipped collect or third party.

Before operating any equipment, always read and familiarize yourself with all operation and safety 

instructions.

Omcan would like to thank you for purchasing this machine. It’s of the utmost importance to save 

these instructions for future reference. Also save the original box and packaging for shipping the 

equipment if servicing or returning of the machine is required.

---------------------------------------------------------------------------------------------------------------------------------------------------

Omcan Fabrication et distribution Companie Limité et Food Machinery d’Amerique, dba Omcan et 

Omcan Inc. ne sont pas responsables de tout dommage ou blessure causé du fait que toute personne 

ait utilisé cet équipement de façon irrégulière. Le produit ne doit être exploité que par quelqu’un de 

plus de 18 ans, saine d’esprit, et pas sous l’influence d’une drogue ou d’acohol, qui a été formé pour 

utiliser cette machine correctement, et est vêtu de vêtements de sécurité approprié. Toute modification 

de la machine annule toute garantie, et peut causer un préjudice à des personnes utilisant la machine 

ou des personnes à proximité de la machine pendant son fonctionnement.

VÉRIFIEZ LE COLIS DÈS RÉCEPTION

Dès réception d’une expédition d’Omcan veuillez inspecter pour dommages externes. Si aucun dommage 

n’est visible sur l’emballage externe, ouvrez le carton afin de s’assurer que tous les éléments commandés 

sont dans la boîte, et il n’y a aucun dommage dissimulé à la machine. Si le colis n’a subi aucune mauvaises 

manipulations, de bosses ou de dommages (visible ou cachée), notez-le sur le bond de livraison avant 

d’accepter la livraison et contactez Omcan dans les 24 heures qui suivent, pour que nous puissions engager 

une réclamation auprès du transporteur. Un rapport détaillé sur l’étendue des dommages causés à la machine 

doit être rempli dans un délai de trois jours, à compter de la date de livraison indiquée dans les documents 

d’expédition. Omcan n’a aucun droit de recours pour les produits endommagés qui ont été expédiées ou cueilli 

par un tiers transporteur.

Содержание RS-CN-0120-B

Страница 1: ...d 01 29 2021 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Refrigerated Showcases Models RS CN 0120 B 0200 B 0120 S 0200 S Items 50077 50078 50079 50080 Instruction M...

Страница 2: ...on Disclaimer General Information Safety and Warranty Technical Specifications Installation and Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Warranty Registration Model...

Страница 3: ...NOT RESPONSIBLE FOR ANY DAMAGES DUE TO WATER LEAKS WARRANTY FOR WATER LEAKS IS VOID IF THE AMBIENT ROOM TEMPERATURE EXCEEDS 75 F AND 55 RELATIVE HUMIDITY AND THE APPLIANCE DRAIN IS NOT CONNECTED DIRE...

Страница 4: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Страница 5: ...ol y que este ha sido entrenado en el correcto funcionamiento de esta m quina y sta usando ropa apropiada y autorizada Cualquier modificaci n a la m quina an la la garant a y puede causar da os a las...

Страница 6: ...ation Unit should be placed far from any heating source to avoid decrease of refrigeration efficiency Install the refrigerator in a dry place to prevent rust from forming on the compartment body which...

Страница 7: ...lug which mates with a standard grounding wall outlet to minimize the possibility of electric shock hazard If the outlet is a standard 2 prong outlet it must be replaced with the properly grounded wal...

Страница 8: ...lead to service difficulties Should it ever become necessary to replace the temperature control it should be ordered from your dealer or recommended service agent LIGHT SWITCH LOCATION The light switc...

Страница 9: ...Impression is for stubborn stains and discoloration Rub in direction of polish lines Easy off and De Grease It oven aid are excellent for removals on all finishes for grease fatty acids blood and bur...

Страница 10: ...tional cleaners are loaded with chlorides the industry is providing an ever increasing choice of non chloride cleaners If unsure of chloride content contact the cleaner supplier If present cleaner con...

Страница 11: ...temperature is too warm Thermostat set too warm Set thermostat to lower temperature Blocking air flow Re arrange product to allow for proper air flow Make sure there is at least four inches of cleara...

Страница 12: ...12 Parts Breakdown Model RS CN 0120 B 50077 Model RS CN 0120 S 50079...

Страница 13: ...135 Power Cord for 50077 26 AB659 Support Holder of Cabinet for 50077 45 AB638 Fixed Board of Curve Glass for 50077 9 AE984 Thermostat Installation Cover for 50077 27 AB660 Cover Board of Machine Room...

Страница 14: ...135 Power Cord for 50079 26 AB659 Support Holder of Cabinet for 50079 45 AB638 Fixed Board of Curve Glass for 50079 9 AE984 Thermostat Installation Cover for 50079 27 AB660 Cover Board of Machine Room...

Страница 15: ...15 Parts Breakdown Model RS CN 0200 B 50078 Model RS CN 0200 S 50080...

Страница 16: ...A249 Condenser Fan Motor Cover for 50078 45 AB762 Fixed Board of Curve Glass for 50078 9 AB604 Sealing Rubber Strip for 50078 27 AB657 Left Track of Installation Board for 50078 46 AB763 Curve Glass f...

Страница 17: ...A249 Condenser Fan Motor Cover for 50080 45 AB762 Fixed Board of Curve Glass for 50080 9 AB604 Sealing Rubber Strip for 50080 27 AB657 Left Track of Installation Board for 50080 46 AB763 Curve Glass f...

Страница 18: ...18 Electrical Schematics Model RS CN 0120 B 50077 Model RS CN 0200 B 50078 Model RS CN 0120 S 50079 Model RS CN 0200 S 50080...

Страница 19: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Страница 20: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Отзывы: