8
Operation
CONTROL BOARD CHECKS
Timer Initiate
The timer initiate is a temperature sensor mounted on the liquid line to the evaporator. When the sensor
detects the correct low temperature, the freeze timer starts and the machine enters the timed portion of the
freeze cycle. When the freeze timer starts, the machine is in the timed portion of the freeze cycle. When
the machine enters harvest, the temperature rises, but the amount of time the machine is in harvest is
predetermined and is controlled by the Controller Board. Once the time has passed, the machine will enter the
harvest cycle. The timer is not adjustable, but the temperature at which the timer is initiated is adjustable.
ICE SIZE ADJUSTMENT
1. Press and hold the “Clean” button and the “Mode” button together for at least 3 seconds. The unit will
enter the Ice Size Adjustment mode. The GREEN LED will be blinking continuously during the ice size
adjustment.
2. While in the Ice Size Adjustment mode, press the “Clean” button or the “Mode” button for the desired ice
size.
Smaller ice setting: By pressing the “Clean” button, you can decrease the size of the ice cubes. The RED LED
will flash as you lower the ice size and will finally be blinking at the setting of smallest ice size.
Larger ice setting: By pressing the “Mode” button, you can increase the size of the ice cubes. The YELLOW
LED will flash as the larger size is set and will blink when the setting of largest ice size has been reached. After
10 seconds without any operation, the unit will automatically memorize the current setting and return to the
previous mode.
BIN CONTROL OPERATION
The bin control is used to shut the machine off when the bin fills with ice. The bin control must be checked
upon installation or initial startup and
when performing maintenance. There
is one bin switch for each evaporator.
The actuator arm of the bin switch
comes in contact with the splash
curtain. When the bin is full of ice,
the splash curtain is held open when
ice drops off of the evaporator. This
releases the pressure of the bin switch
actuator arm allowing the switch to
open. Units placed under counters
and machines without curtains: An ice slide at the bottom of the evaporator is used on all under the counter
units and some modular units. The slideway swivels up and down and has a magnetic reed switch which
detects its position. When ice is sitting on the control, the slideway faces down indicating that ice is present
(and disconnecting the circuit from the reed switch). When the ice is removed, the slideway swivels up and the
Содержание IC-CN-0040
Страница 50: ...50 Parts Breakdown Model IC CN 0040 27936...
Страница 52: ...52 Electrical Schematics Model IC CN 0040 27936...