Troubleshooting
Produces proper cubes but is slow in production.
Step
Check
If yes, proceed to
If no, proceed to
D1
Is the unit installed correctly?
D2
Correctly install the unit
D2
Is the head pressure too high?
D3
Check refrigeration system
D3
Is the condenser clean?
Check refrigeration system
Clean
Cubes are hollow.
Step
Check
If yes, proceed to
If no, proceed to
E1
Is the water temperature above
100
°
F?
Correct the temperature
E2
E2
Is there good flow over the
evaporator?
E3
Go to section C
E3
Is there water leaking from the
purge?
Replace valve
E4
E4
Does the cube adjuster work?
Reset cube size
E5
E5
Is the evaporator sensor loose?
Tighten
E6
E6
Is the evaporator sensor wire
tight?
E7
Tight the spade connection to
the board
E7
Is the controller damaged?
Replace
Bridge thickness is uneven.
Step
Check
If yes, proceed to
If no, proceed to
F1
Is the water temperature above
100
°
F?
Correct the temperature
F2
F2
Is the water running into the bin? Check sections C,D, E or
check trough for leak
F3
F3
Is water leaking from the purge?
Replace the valve
F4
F4
Is the suction pressure high?
Check the hot gas valve
Recharge and/or check the
TXV
Bridge thickness varies with each cycle.
Step
Check
If yes, proceed to
If no, proceed to
G1
Is the water temperature proper? Correctly adjust temperature G2
G2
Is the purge valve leaking?
Replace valve
G3
G3
Is the hot gas valve damaged?
Replace
G4
G4
Are sensors connected to the
board?
G5
Tighten spade connections
G5
Is the controller damaged?
Replace
G6
G6
Is the thermal expansion valve
damaged?
Replace