11
Maintenance
Troubleshooting
CLEANING THE FAN BLADES AND MOTOR
If necessary, clean the fan blades and motor with a soft cloth. If it is necessary to wash the fan blades, cover
the fan motor to prevent moisture damage.
CLEANING THE INTERIOR OF THE UNIT
• When cleaning the cabinet interior, us a solvent of warm water and mild soap.
• Do not use steel wool, caustic soap, abrasive cleaners, or bleach that may damage the stainless steel
surface.
• Wash door gaskets on a regular basis, preferably weekly. Simply remove door gasket from the frame of the
door, soak in warm water and soap for thirty (30) minutes, dry with a soft cloth and replace.
• Check door gaskets for proper seal after they are replaced.
• Periodically remove the shelves and pilasters from the unit and clean them with mild soap and warm water.
To remove the pilasters, first remove the shelves and shelf brackets. Then, simply lift the pilaster up and
out.
Warning: Disconnect power cord before cleaning any parts of the unit.
Problem
Possible Cause
Solution
Compressor not running.
Fuse blown or circuit breaker
tripped.
Replace fuse or reset circuit
breaker.
Power cord unplugged.
Plug in power cord.
Thermostat set too high.
Set thermostat to a lower
temperature.
Cabinet in defrost cycle.
Wait for defrost cycle to finish.
Содержание BB-CN-0012E-SH
Страница 13: ...13 Model BB CN 0012E SH 59057 Parts Breakdown...
Страница 15: ...15 Model BB CN 0012E GH 59058 Parts Breakdown...
Страница 17: ...17 Model BB CN 0020E SH 59061 Parts Breakdown...
Страница 19: ...19 Model BB CN 0020E GH 59062 Parts Breakdown...