![background image](http://html.mh-extra.com/html/omcan/46500/46500_instruction-manual_736096010.webp)
10
Installation
the cabinet front (6 o-clock position). You accomplish this by aligning the bottom of the beer tower to the 3
grooves on the top cabinet and tighten by hand clockwise to properly lock.
•
The plastic gasket, can be used to make the connection between the tower and the cooler tighter if needed.
If Beer Tower will not turn to lock in place, try removing the plastic gasket.
INSTALLATION OF PROTECTIVE METAL PLATE
This plate should always be installed when the keg is in place to protect against unnecessary damage to the
floor of the cabinet.
INSTALLATION OF THE BEER KEG
• Position the beer keg directly in front of the open door. Using keg handles only, carefully lift the beer keg.
(See Figure 5)
•
To place the beer keg inside the cabinet, brace your knees behind the beer keg. Lift the front of the keg just
enough so the front edge of the keg is resting on the front edge of the Beer Dispenser bottom cabinet. (See
Figure 6)
•
Grasp the keg handles and slide it all the way into the cabinet.
INSTALLATION OF THE KEG COUPLER
Insert the keg coupler provided into the locking neck of the beer keg and turn it clockwise to lock into position,
making sure the keg coupler is in the closed position. (See Figure 7)
INSTALLATION OF THE CO2 AIR LINE HOSE
Attach the end of the air line (red) hose provided to the hose connection on the keg coupler.
CONNECTING THE BEER TOWER TO COUPLER
•
Make sure the washer is properly inserted into the wing nut.
• Make sure the small round bead is in place (dropped down into the top of the coupler).
• Make sure the ball retainer is in place on the coupler, with the “arms” down into the coupler.
• Place wing nut into the top of the coupler turning until tight.
HOW TO TAP A KEG OF BEER
• Make sure that the CO2 is turned off, and the Secondary valve on the regulator is in the “Closed” position.
• Pull out and release the pressure release valve on the Coupler to purge any air pressure.
•
Make sure the beer tower faucet is in the closed position.
• Pull tapping handle out and press downward until it locks into position. (See Figure 8) The keg is now
tapped.
OPENING THE CO2 CYLINDER MAIN VALVE
• Make sure the secondary shut-off valve (shown in figure 9 in “Open” position) is closed. To open the main
CO2 cylinder valve, slowly turn the main valve counter-clockwise until fully open.
•
Notice the needle on the regulator gauge start to climb.
ADJUSTING THE CO2 REGULATOR
The gauge monitors low internal keg pressure and should be adjusted to read between 10-12 psi. (See Figure
10). The pressure can be adjusted as needed.