background image

EN

5

INDICATIONS FOR USE

The 

Ombra

* Table Top Compressor is designed to deliver compressed air to a jet or pneumatic nebulizer. This compressor 

may be used with adult, child or paediatric patients. The 

Ombra

* Table Top Compressor is a medical device, and should 

only be used as directed by your healthcare professional. The intended environments for use include the home, hospitals 

and clinics.
The compressor has been designed for use with the reusable 

AEROECLIPSE

* XL Breath Actuated Nebulizer (BAN). For use 

with other nebulizers, please ensure you refer to the Technical Specification Table to ensure compatibility. If you are unsure 

if your nebulizer is compatible with the 

Ombra

* Table Top Compressor, please consult with your healthcare professional 

before use as it could affect the effectiveness of your treatment.
Be sure to read all of the instructions before using your new 

Ombra

* Table Top Compressor. These instructions should be 

stored in a safe place for future reference as this booklet contains important information about the proper functioning of your 

compressor. Failure to observe these instructions may result in injury and/or damage to the compressor.

IMPORTANT SAFETY INFORMATION

The following statements will be used to draw attention to potential use errors that could cause harm.

     NOTE

 - Indicates information to which the user should pay special attention.

  

CAUTION

 - Information for preventing damage to the product.

  

WARNING

 - Important safety information for hazards that could cause serious injury.

  

DANGER

 - Urgent safety information for hazards that will cause serious injury or death.

ELECTRICAL SAFETY

As with any electrical device, extra precautions should be taken to prevent injury or death. Special attention should be paid 

when using electrical appliances around young children. Always unplug the compressor when not in use.

 

DANGER:

 To reduce the risk of serious injury or death from electrocution:

•  Do not use or store this device where it can fall or be pulled into water or other liquid, such as a bathtub or sink. Do not 

use while bathing.

•  If the compressor falls into water or other liquid, do not reach for it. Unplug the compressor immediately.
•  If the power cord appears damaged or frayed, the compressor should not be used and should be unplugged immediately.

  

WARNING:

 To prevent serious injury, fire or burns and to reduce the risk of damage to the product:

1.

  Ensure you are using the correct compressor for the voltage and current available. This information will be printed on 

the label on the bottom of your compressor.

 

120 Volt Compressor

 

The polarized plug will only fit fully into the electrical outlet when it is positioned the correct way. If you are having 

difficulty plugging the compressor in, reversing the plug may resolve this.

2.

 The 

Ombra*

 Table Top Compressor should be unplugged when not in use. Do not plug the compressor into an 

electrical outlet that makes it hard to disconnect from the power source or where the outlet is hard to access. The AC 

power plug is served to disconnect the device.

3.

  Never operate the compressor if:

 

a.

  It appears to have damage to the power cord, power cord connection or plug;

 

b.

  It has been dropped or damaged;

 

c.

  It has been exposed or dropped into water or other liquids;

 

d.

  It does not appear to be operating properly.

 

If any of these occur, return the compressor to your 

Ombra

* Authorized Distributor for replacement.

4.

  Keep any electrical cords away from sources of heat and avoid overloading electrical outlets.

5.

  Never use the compressor when sleeping or drowsy.

6.

  Do not operate or store the compressor where the 

AIR VENTS

 may be obstructed as this may cause the compressor 

to overheat. The 

Ombra*

 Table Top Compressor has a safety feature that will automatically shut off the compressor if 

it overheats. If this occurs, wait 30 minutes before turning the compressor back on.

7.

  The compressor surfaces may become hot during prolonged treatments. Allow surfaces to cool before handling to 

avoid contact burns.

8.

  Compressor should be used on a clean, flat surface. Do not use or store the compressor in areas where there is 

excessive dust or particulate matter in the air. Compressor should only be used indoors.

9.

  This compressor should not be used near where oxygen is being administered or in the presence of any flammable 

material and/or gas.

Содержание 120v

Страница 1: ...Owner s Manual Manuel de l utilisateur Manual de instrucciones EN FR ES ZH Table of Contents 1 Table des mati res 10 ndice 20 30...

Страница 2: ......

Страница 3: ...EZ Twist Tubing 8 Compressor 8 Storage 8 Disposal 9 Technical Speci cations 9 Consult instructions for use Disposal of Electrical Electronic Equipment WEEE Indoor use only Class II Type BF Applied Pa...

Страница 4: ...g items Reusable AEROECLIPSE XL Breath Actuated Nebulizer package includes an owner s manual two nebulizers with mouthpiece and two EZ Twist Tubes Ombra Table Top Compressor Owner s Manual this guide...

Страница 5: ...EN 3 Air Outlet Air Filter Cover Power Cord Nebulizer Cup Holder FIGURE 1 Top View No Slip Rubber Feet ON OFF Switch Air Vents Regulatory Label Side View...

Страница 6: ...EN 4 FIGURE 2 Green Feedback Button Mode Selector White Cylinder mL Markings Stem One Way Exhalation Valve Owner s Manual EZ Twist Tubing Nebulizer Cup Nebulizer Top Mouthpiece...

Страница 7: ...athing If the compressor falls into water or other liquid do not reach for it Unplug the compressor immediately If the power cord appears damaged or frayed the compressor should not be used and should...

Страница 8: ...RE YOU BEGIN For compressor part descriptions see Figure 1 Ensure you have thoroughly read and understood all of the instructions for use for your Ombra Table Top Compressor before you begin your trea...

Страница 9: ...n a relaxed comfortably seated position pick the nebulizer up out of the CUP HOLDER Switch on the compressor and start your treatment 8 When your treatment is complete or during a rest in your treatme...

Страница 10: ...Z TWIST TUBING Occasionally you may notice condensation on the inside of your oxygen tubing This is normal To remove the condensation simply connect one end of the EZ Twist TUBING to the AIR OUTLET on...

Страница 11: ...w Adapter Large 5 years 10550493010 Air Filters 5 pk 105544 001 TECHNICAL SPECIFICATIONS See label on bottom of compressor to verify your compressor voltage 120 Volt Compressor Model Number 105510 Wei...

Страница 12: ...sage 18 limination 18 Caract ristiques techniques 19 Consulter le mode d emploi limination des mat riels lectriques et lectroniques WEEE Utilisation l int rieur exclusivement Cat gorie II Pi ce en con...

Страница 13: ...ctionn par la respiration AEROECLIPSE XL r utilisable l ensemble comprend un manuel de l utilisateur deux n buliseurs avec embout buccal et deux tubulures EZ Twist Manuel de l utilisateur du compresse...

Страница 14: ...rtie d air Couvercle du filtre air C ble d alimentation Porte coupelle du n buliseur Vue de dessus Pieds en caoutchouc antid rapant Interrupteur MARCHE ARR T vents tiquette r glementaire Vue lat rale...

Страница 15: ...rt de r troaction S lecteur du mode Cylindre blanc Rep res ml Tige Soupape d expiration unidirectionnelle Manuel de l utilisateur Tubulure EZ Twist Coupelle du n buliseur Dessus du n buliseur Embout b...

Страница 16: ...ompresseur lorsqu il n est pas utilis DANGER Pour r duire le risque de l sions graves ou de mort la suite d une lectrocution Ne pas utiliser ni entreposer ce dispositif un endroit o il risque de tombe...

Страница 17: ...ion NE PAS LAISSER LES ENFANTS SANS SURVEILLANCE PENDANT LES TRAITEMENTS AVANT DE COMMENCER Voir la figure 1 la description des pi ces du compresseur S assurer d avoir lu et compris int gralement l en...

Страница 18: ...extr mit la SORTIE D AIR du compresseur S assurer que les deux extr mit s sont bien enclench es Le n buliseur peut ensuite tre plac dans le PORTE COUPELLE du compresseur jusqu ce que l on soit pr t co...

Страница 19: ...e se fera sentir lorsque le COUVERCLE DU FILTRE AIR est bien fix FIGURE 8 90 90 ATTENTION Ne pas laver ni r utiliser le filtre usag Utiliser exclusivement des filtres de rechange Ombra r f rence 10554...

Страница 20: ...tretenu ou r par s adresser au distributeur agr Ombra AVERTISSEMENT Aucune modification de ce mat riel n est autoris e LIMINATION Ce produit entre dans le champ d application de la directive 2002 96 C...

Страница 21: ...Dimensions 17 8 cm x 15 5 cm x 10 cm 7 po x 6 1 po x 3 9 po Niveau sonore 60 dB A Sp cifications lectriques 120 V Longueur du c ble d alimentation 1 52 m 5 pieds Puissance 132 VA Fr quence 60 Hz Cycl...

Страница 22: ...resor 28 Almacenamiento 28 Desecho 28 Caracter sticas t cnicas 29 Consultar las instrucciones de uso Desecho de equipos el ctricos y electr nicos Disposal of Electrical Electronic Equipment WEEE Exclu...

Страница 23: ...or accionado por respiraci n AEROECLIPSE XL reutilizable el paquete incluye un manual de instrucciones dos nebulizadores con boquilla y dos tubos EZ Twist Manual de instrucciones del compresor Ombra d...

Страница 24: ...a del filtro de aire Cable de alimentaci n Soporte de la copa del nebulizador FIGURA 1 Vista superior Patas de goma antideslizantes Interruptor de encendido y apagado Orificios de ventilaci n Etiqueta...

Страница 25: ...Bot n verde de feedback Selector de modo Cilindro blanco Marcas de ml V stago V lvula de exhalaci n unidireccional Manual de instrucciones Tubo EZ Twist Copa del nebulizador Parte superior del nebuli...

Страница 26: ...erca de ni os peque os Desconecte siempre el compresor cuando no est en uso PELIGRO Para reducir el riesgo de lesiones graves o la muerte como consecuencia de descargas el ctricas No utilice ni almace...

Страница 27: ...oximidades Contiene componentes que pueden constituir un riesgo de descarga o estrangulamiento NO DEJE A LOS NI OS SIN ATENCI N DURANTE LOS TRATAMIENTOS ANTES DE COMENZAR Para ver una descripci n de l...

Страница 28: ...tal como se muestra en la Figura 7 6 Enchufe el compresor Ombra de sobremesa a la toma el ctrica 7 Mientras est sentado en una posici n c moda y relajada coja el nebulizador y s quelo del SOPORTE PARA...

Страница 29: ...iltro nuevo en la cubierta vuelva a colocar la CUBIERTA DEL FILTRO DE AIRE en el compresor y g rela hacia la derecha unos 90 grados para apretarla 4 No la apriete demasiado Experimentar una cierta res...

Страница 30: ...presor Ombra de sobremesa y el BAN AEROECLIPSE XL reutilizable siempre se deben almacenar juntos con todos los componentes en un entorno seco y sin polvo PELIGRO No intente desmontar la carcasa del co...

Страница 31: ...sonoro 60 dB A Requisitos el ctricos 120 voltios Longitud del cable de alimentaci n 1 52 metros 5 pies Alimentaci n 132 VA Frecuencia 60 Hz Ciclo de trabajo 30 minutos encendido 30 minutos apagado Esp...

Страница 32: ...ZH 30 WEEE II BF UL 60601 1 CAN CSA C22 2 No 601 1 C US 72DG 31 34 34 34 35 37 37 37 EZ Twist 37 37 37 37 38...

Страница 33: ...ZH 31 AEROECLIPSE EZ Twist Ombra Ombra...

Страница 34: ...ZH 32 1...

Страница 35: ...ZH 33 EZ Twist 2...

Страница 36: ...ZH 34 Ombra Ombra AEROECLIPSE BAN Ombra Ombra 1 120 2 Ombra 3 a b c d Ombra 4 5 6 Ombra 30 7 8 9 10 11 12 Ombra...

Страница 37: ...ZH 35 13 Ombra Ombra 14 1 Ombra www aeroeclipse com 1 3 4 5 2 AEROECLIPSE BAN 3 2 ComfortSeal 4 AEROECLIPSE 5...

Страница 38: ...ZH 36 6 7 4 6 5 EZTwist 7 6 Ombra 7 8...

Страница 39: ...ZH 37 Ombra 6 8 1 90 2 3 90 4 8 90 90 Ombra 105544 001 AEROECLIPSE EZ TWIST EZ Twist Ombra Ombra AEROECLIPSE Ombra 2003 1 27 2002 96 EC 8...

Страница 40: ...52 132 60 30 30 5A 15 40 59 104 15 95 20 60 4 140 15 95 37 0 psi 2 55 9 5 19 5 psi 1 34 4 0 3 2012 1 Ombra www aeroeclipse com AEROECLIPSE AEROECLIPSE EZ Twist 10551393010 ComfortSeal 0 18 10550393010...

Страница 41: ...39...

Страница 42: ...40...

Страница 43: ......

Страница 44: ...ng Limited 758 Third Street London Ontario Canada N5V 5J7 Email tmml tmml com Website www tmml com Trudell Medical International Europe Ltd BioCity Nottingham Pennyfoot Street Nottingham NG1 1GF UK Em...

Отзывы: