CLEANING AND MAINTENANCE
AIR FILTER
Your
Ombra
* Table Top Compressor is equipped with a special air filter that will slowly change colour with use. The original
filter is bright white, but it will slowly turn grey with use. Your air filter should be changed every 6 months, or more often as
visual inspection indicates. The compressor should never be used without an air filter installed.
To change the filter (Figure 8)
1.
Remove
AIR FILTER COVER
by holding the cover and turning counterclockwise approximately 90 degrees. Pull the
cap and filter cover out.
2.
Remove filter from the cover, and dispose of the old filter.
3.
Insert a new filter into the cover, then place the
AIR FILTER COVER
back into the compressor and turn clockwise
approximately 90 degrees to tighten.
4.
Do not over tighten. There will be resistance when the
AIR FILTER COVER
is securely fastened.
FIGURE 8
90˚
90˚
CAUTION:
Do not wash or reuse the filter. Use only
Ombra
* Replacement Filters (Part Number: 105544-001). Do not
attempt to substitute any other material to act as a filter as this will result in damage to the compressor and may void your
warranty.
NEBULIZER
Refer to the
OWNER’S MANUAL
included with your reusable
AEROECLIPSE
* XL BAN for instructions on how to properly
clean your nebulizer.
EZ TWIST
TUBING
Occasionally you may notice condensation on the inside of your oxygen tubing. This is normal. To remove the condensation,
simply connect one end of the
EZ Twist
TUBING
to the
AIR OUTLET
on the compressor and allow the compressor to run
without the nebulizer attached. This will force air through the tubing, drying the inside. To clean the exterior, wipe with a damp
cloth. Ensure the tubing is dry prior to storage.
COMPRESSOR
Prior to cleaning the compressor, ensure the unit is unplugged from the electrical outlet. Use a damp cloth to wipe the
exterior of the compressor housing. Never use liquid or spray cleaners directly on the compressor.
CAUTION:
Liquids can cause damage to the electrical components inside your compressor and lead to malfunction.
In the event any liquid enters the unit, please contact your
Ombra*
Authorized Distributor. Do not use the compressor until
it has been inspected, even if it appears to be functioning properly.
STORAGE
The
Ombra*
Table Top Compressor and reusable
AEROECLIPSE*
XL BAN should always be stored together with all of the
parts in a dry, dust-free environment.
DANGER:
Do not attempt to disassemble the compressor housing as this presents an electric shock hazard. There are
no parts inside the compressor housing that require maintenance or replacement. Should you require repair or service for
your compressor, please contact your
Ombra*
Authorized Distributor.
WARNING:
No modification of this equipment is allowed.
Содержание 120v
Страница 2: ......
Страница 32: ...ZH 30 WEEE II BF UL 60601 1 CAN CSA C22 2 No 601 1 C US 72DG 31 34 34 34 35 37 37 37 EZ Twist 37 37 37 37 38...
Страница 33: ...ZH 31 AEROECLIPSE EZ Twist Ombra Ombra...
Страница 34: ...ZH 32 1...
Страница 35: ...ZH 33 EZ Twist 2...
Страница 36: ...ZH 34 Ombra Ombra AEROECLIPSE BAN Ombra Ombra 1 120 2 Ombra 3 a b c d Ombra 4 5 6 Ombra 30 7 8 9 10 11 12 Ombra...
Страница 37: ...ZH 35 13 Ombra Ombra 14 1 Ombra www aeroeclipse com 1 3 4 5 2 AEROECLIPSE BAN 3 2 ComfortSeal 4 AEROECLIPSE 5...
Страница 38: ...ZH 36 6 7 4 6 5 EZTwist 7 6 Ombra 7 8...
Страница 41: ...39...
Страница 42: ...40...
Страница 43: ......