FM TRANSMITTER
TR
EM
1000
HE
DIG
PLUS
COMPACT
Technical Manual 1v2 November 2019
58
To set automatic power reduction:
1) Ensure that the
EDIT
option is selected; otherwise, turn the knob to select it, then press to
confirm. A value will be displayed after
OFF
or
ON
.
2) Turn the knob to set
OFF
or
ON
according to your requirements, then press to confirm. A
value will be indicated after
reduce
.
3) Turn the knob to change the power reduction percentage, then press to confirm. The first
number (hour) will be highlighted after
from
.
4) Turn the knob to change the hour in which the power reduction will start (24-hour clock),
then press to confirm. The second number (minutes) will be highlighted after
from
.
5) Turn the knob to change the minute in which the power reduction will start, then press to
confirm. The first number (hour) will be indicated after
to
.
6) Repeat steps 4 and 5 to set the time in which the transmitter will return to normal power.
7) Using the knob, select
OK
to save the settings,
EDIT
to make further changes, or
ABORT
to
exit without saving the new settings, then press to confirm.
- MODEM setting
If the transmitter is equipped with an optional modem, its parameters can be defined via this
screen. For further details, refer to the documentation provided with this option.
If a modem has not been installed, the screen will indicate
Modem not present
.
- Hidden menus (under level 3 password)
Beside the two level 1 and level 2 passwords, a third password, called “level 3 password” is
available. It’s preset during the production, it’s always active and allows to access the
SETUP
sub menu and the one which allows the activation/change of the level 1 and level 2
passwords even when the user has activated and forgotten them.
There are two hidden menus which can be accessed only by entering the level 3 password.
Briefly, accessing the
SETUP
menu by means of the level 3 password allows to:
• Access the
SETUP
sub menu and the one which allows the activation/change of the level 1
and level 2 passwords even when the user has activated and forgotten them.
• Change the level 3 password in order to change the one preset during the production of the
equipment.
- Accessing the level 3 password
To access the
SETUP
submenu when you have forgotten the level 1 or level 2 password
currently active:
1) Use the knob to select the
SETUP
menu and press it to confirm.
2) When the password is prompted, enter the level 3 password which was set during the
production to
A B C D
.