www.microscopenet.com

 

- 9 - 

Eyepieces 

Designation 

Magnification 

Field of View 

Mount Size 

Wide Field 

10X 

18mm 

23.2mm 

 

Wide Field 

20X 

10mm 

23.2mm 

 

 

Magnifications

 

   

 

Eyepiece 

10X 

20X 

10X 

20X 

10X 

20X 

10X 

20X 

Objective 

4X 

10X 

40X 

100X 

Magnification 

40X 

80X 

100X 

200X 

400X 

800X 

1000X 

2000X 

 
 
 
 

5

 

Optional Parts 

(The optional parts may be included in some models or sold separately.) 
 

1)  Darkfield Condensers 

 

Model 

Darkfield 

Condenser

 

Numerical 

Aperture 

Objective 

Mounting 

Size(diameter) 

 

A191 

Dry 

0.7-0.9 

37mm 

 

2)  Cameras 

 

Model 

Resolution 

Operating System 

Software 

 

A1502 

640 x 480 (0.3MP) 

MS Windows 

(32/64-bit) 

Mac OS 

Included 

 

A1510 

1280 x 1024 (1.3MP) 

MS Windows 

(32/64-bit) 

 

A1520C 

1600 x 1200 (2.0MP) 

MS Windows 

(32/64-bit) 

Mac OS 

Содержание M82ES Series

Страница 1: ...User Manual Binocular Compound Microscope Model M82ES Series MicroscopeNet com...

Страница 2: ...aution 1 ii Care and Maintenance 2 1 Component Illustration 3 2 Installation 4 3 Operation 5 4 Specifications 8 5 Optional Parts 9 6 Troubleshooting Guide 10 7 Dry Darkfield Condenser Installation Ope...

Страница 3: ...t of direct sunlight high temperature or humidity and dusty environments Ensure the microscope is located on a smooth level and firm surface 4 If any specimen solutions or other liquids splash onto th...

Страница 4: ...ng an excessive amount of solvents as this may cause problems with optical coatings or cemented optics or the flowing solvent may pick up grease making cleaning more difficult Oil immersion objectives...

Страница 5: ...5 Objective 18 Power Switch 6 Slide Holder 19 Brightness Intensity Dial 7 Mechanical Stage 20 Immersion Oil 8 Light Collector 21 Dust Cover 9 Microscope Base 22 Condenser Lock Thumb Screw 10 Eyepiece...

Страница 6: ...lled securely 2 2 Installation of the eyepieces 1 Remove the protective caps from the eyepiece tubes 2 Insert the eyepieces into the eyepiece tubes 2 3 Installation of the glass filter 1 Swing out the...

Страница 7: ...ve to touch a specimen slide when changing objectives 3 3 Adjusting interpupillary distance While observing with both eyes hold the left and right eyepiece tubes and slide the tubes in and out The int...

Страница 8: ...iece to seat the observing position between the 40X and 100X objectives as shown in Fig 6 a 2 Place a drop of immersion oil on the slide cover as shown in Fig 6 b 3 Rotate the objective nosepiece to s...

Страница 9: ...adjust the brightness although the brightness will be changed when it s adjusted When aperture is adjusted to smaller size the contrast will be increased and the depth of field will be increased as we...

Страница 10: ...0 17 spring oil Condenser Abbe NA 1 25 w iris diaphragm Rack and pinion adjustment Focus Mechanism Coaxial coarse and fine focusing knobs on both sides with rack stop Mechanical Stage Double layer di...

Страница 11: ...200X 400X 800X 1000X 2000X 5 Optional Parts The optional parts may be included in some models or sold separately 1 Darkfield Condensers Model Darkfield Condenser Numerical Aperture Objective Mounting...

Страница 12: ...sed image No slide cover attached to the slide Attach a 0 17mm slide cover Slide cover is too thick or thin Use a slide cover of the appropriate thickness 0 17mm Slide may be upside down specimen at t...

Страница 13: ...e the bolt to lock it when needed Note When raising the mechanical stage do not make contact with the objective 2 Centering the dry darkfield condenser Turn the 4X objective to the light path Turn the...

Отзывы: