D877 MGB Rev01 HE250.docx
29/50
3.8.2
Always check signal OFF
Change the P461 parameter to 2.
Perform a maneuver in any direction.
At the end of the maneuver, the control system, must indicate an error state Error 2 corresponding to the signal
PNP1 (Error 1).
Reset on the panel the error, re-start the lift.
3.8.3
Verification normal operation
At the end of a maneuver as described in point 3.8.1 or 3.8.2 the P461 parameter automatically returns to the
value 0 which corresponds to the normal operating condition, otherwise manually modify the P461 parameter
to return to the value 0.
Perform a maneuver, in any direction to ensure that, does not appear no error corresponding to PNP1 signal
3.9
Identification and traceability
Sul gruppo valvole viene applicata una targa riportante il nome e indirizzo del Produttore, il numero di serie, il
tipo/modello e i dati di certificazione oltre ad un QR code. The valve group is applied a plaque showing the
name and address of Manufacturer, serial number, the type / model and the certification data in addition to a
QR code.
The serial number is the identification of the installation and component and allows the coupling to the
corresponding "EU Declaration of Conformity". OMARLIFT keeps a database in the list of Customer, Customer
Order Reference, number of component series which allows traceability with historical sampling archives and
manufacture of components.
The content QR TAG is shown in the following table:
Pos.
Field content
Type
Length. max Sample content
1
Type and component model
CHAR
40
HEVOS HE 250
2
Not used
CHAR
2
3
Not used
CHAR
2
4
Sales Reference
CHAR
35
ALR1420809 HDU
5
Serial number
CHAR
18
639204
6
Not used
CHAR
10
- - -
7
Maker
CHAR
30
OMARLIFT
8
Postal code
CHAR
10
24060
9
City
CHAR
30
Bagnatica (Bg)
10
Country code
CHAR
5
IT
11
Not used
CHAR
30
- - -
12
Not used
CHAR
10
- - -
13
Not used
CHAR
30
- - -
14
Not used
CHAR
5
- - -