37
In the case of the main power supply failure, or when voltage drops below 42 volts, fault message
„Voltage“
appears, transmitting will be blocked. We recommend to
switch PA
immediately
OFF
in such a case. You have
to contact manufacturer or your dealer for assistance.
When the amplifier reaches inside temperature of 75
deg. Celsius, warning message
„Temp“
appears on the
display.
Fault LED
starts blinking. At 80 degrees protection circuit will automatically block transmitting (fault
condition). You have to decrease the power or wait couple of minutes to be ready transmitting again. Touch
RESET
.
If current of the PA exceeds the limit value,
„Current“
fault message appears on the display, transmitting will
be blocked. Decrease input power first, touch
RESET
and try to transmit again. If this will not help and current
will stay high, contact the manufacturer for assistance.
CAUTION
If MOSFET is destroyed, do NOT attempt to replace it, in any case! Contact the manufacturer immediately.