27
5.3.3.
Display delay
Display will not turns OFF Display turns OFF after 10 sec. Display turns OFF after 1 min (max.)
5.3.4. Bias switch
Electronic Bias Settings (EBS) is one of significant feature of the power amplifier. It allows to set low drain current
(abt. 300mA) after pressing the PTT, until RF signal is no present at the input. At the moment when RF signal
comes to the input of the PA, bias will automatically change its value to the higher level (abt. 2.5A),
independently on the selected operation mode in the TCVR....... EBS is default activated.