IMPORTANT

1.  After the equipment has been used in an observation of a 

specimen that is accompanied with a potential of infection, clean 
the parts coming in contact with the specimen to prevent infection.

· Moving this microscope is accompanied with the risk of 

dropping the specimen. Be sure to remove the specimen 
before moving this product.

The SZ2 series of stereo microscopes are provided with ESD (Electro-Static Discharge) protection specifications. They are 
provided with electroconductive coating in their external finish to reduce the surface resistance and grounding lead wires 
in their standard base or frame to eliminate static electricity from them.

To maintain the ESD protection performance, always use the microscope in combination with the 
modules described in this manual or options having the ESD protection specifications. Otherwise, the 
grounding will not work properly.

·

The eye shades of the eyepieces are not provided with the ESD protection performance. Be sure to 
remove them

·

The SZ2-SPBW stage plate is provided with the ESD protection performance only in the black surface.

NOTE

 SAFETY PRECAUTIONS

b

a

· Hold the bottom of the stand with one hand while holding base column with the other hand to avoid tilting the 

microscope.

· In case the specimen is damaged by erroneous operation, promptly take the infection prevention measures.

2.  When the optional 0.5X auxiliary objective  a  is used, the microscope become unstable due to the use of the SZ2-

ET auxiliary sleeve  b . Be careful not to topple down the microscope. )
In addition, when a camera is mounted on the SZ61TR, special care is required because the microscope becomes 
more unstable.

1

Getting Ready

1.  A microscope is a precision instrument. Handle it with care and avoid subjecting it to sudden or severe impact.
2.  Do not use the microscope where it is subjected to direct sunlight, high temperature and humidity, dust or 

vibrations. (For the operating conditions, see “SPECIFICATIONS” on page 13.)

3.  Be careful not to leave stains and fingerprints on the lens surfaces.

Contamination of the lens and mirror deteriorates the view of images.

4.  Do not turn the left and right zoom adjustment knobs in the opposite directions, as this will result in a failure.
5.  The rubber parts of the eyepiece sleeves are fragile and should be handled carefully. If they are damaged, dirt will 

penetrate inside the microscope.

Downloaded from 

ManualsNet.com

 search engine

Содержание SZ61

Страница 1: ...this manual thoroughly before operating the microscope Retain this instruction manual in an easily accessible place near the work desk for future reference For details of products included in the conf...

Страница 2: ...Downloaded from ManualsNet com search engine...

Страница 3: ...Zoom Magnification Stopper 8 4 Using the Eye Shades 8 5 Mounting the Eyepiece Micrometer Disk 9 6 Using the Auxiliary Objectives 10 7 Selecting the Light Path SZ61TR 10 8 Adjusting the Confocality of...

Страница 4: ...Downloaded from ManualsNet com search engine...

Страница 5: ...SAFETY PRECAUTIONS b a Hold the bottom of the stand with one hand while holding base column with the other hand to avoid tilting the microscope In case the specimen is damaged by erroneous operation...

Страница 6: ...the instructions in the warning could result in bodily harm to the user and or damage to equipment including objects in the vicinity of the equipment NOTE Indicates that failure to follow the instruct...

Страница 7: ...crew x 2 Accessory mount holes Eyepiece WHSZ10X WHSZ10X H WHSZ15X H WHSZ20X WHSZ20X H WHSZ30X H Body clamping knob Threaded for accessory mounting Microscope Body SZ61 SZ61 60 SZ61TR SZ51 SZ51 60 Stag...

Страница 8: ...clamping screw Confocality adjustment clamping screw Page 11 x 2 Light path selector lever Page 10 Pulled out Camera path 100 Right eyepiece sleeve light path 0 Pushed in Right eyepiece sleeve light p...

Страница 9: ...6 Adjust the interpupillary distance Page 6 1 2 Adjust the eyepiece diopter Page 7 This operation is not possible with the eyepieces without helicoids WHSZ10X 20X The operation is slightly difference...

Страница 10: ...set the knob tension to a slightly higher level than the point where spontaneous drop occurs Hold the left and right focus adjustment knobs a with both hands fix the left knob and rotate the right kn...

Страница 11: ...easy to observe specimen on the stage plate Set the zoom adjustment knob c for low magnification look through the eyepiece with eyepiece micrometer disk and rotate the focus adjustment knob d to bring...

Страница 12: ...on each zoom adjustment knob The right zoom adjustment knob is used to limit the higher end of the magnification and the left knob is used to limit the lower end Using an Allen wrench loosen the clamp...

Страница 13: ...ch it firmly Themicrometerdiskframemaybetightforcertainmicrometerdisks In this case turn the frame by holding the circumference with a light uniform force or by applying the frame against a rubber she...

Страница 14: ...of the auxiliary objectives are provided with the ESD protection performance The 0 3X and 0 4X auxiliary objectives cannot be used in combination with the standard base because their working distance...

Страница 15: ...monitor image After the adjustment tighten the clamping screws b and c Applicable cameras image pickup device size and field numbers The camera light path incorporates a 0 5X lens TIP 1 2 3 4 TIP a b...

Страница 16: ...does not rotate smoothly The rotation tension of the knob is set too high Decrease the rotation tension to an optimum level 6 6 The microscope body drops spontaneously causing the focusing to be devia...

Страница 17: ...eyepiece micrometer disk mountable Standard stand SZ2 ST Frame installation Mounting diameter 76 mm Focus adjustment Rack and pinion using ball guide Knob rotation tension adjustable Focusing stroke 1...

Страница 18: ...5X 2 200 110AL2X 2 38 110AL0 62X 160 The working distances of the 110ALK0 3X and 0 4X can be varied according to the system The indicated magnifications 0 3X and 0 4X are the values when the working d...

Страница 19: ...NOTE To reserve the ESD protection performance be sure to ground the equipment using a grounding lead wire having a 4 mm banana plug The eyepieces are provided with theft prevention screws which can...

Страница 20: ...e microscope body can be installed in the opposite orientation to that shown in figure at the 180 rotated position TIP 3 Mounting the Stage Plate Mounting While applying the stage plate c to the stage...

Страница 21: ...C mount clamping screw a and remove the C mount seat b Screw the C mount seat b into the camera c Place the C mount seat in the original position and tighten the clamping screw a Connect the cables an...

Страница 22: ...sleeve when the SZ2 ST is used or the SZH P400 auxiliary column and the SZX R drop prevention ring also when the SZX2 ST or SZX2 illumination base is used 2 Applicable Bases and Restrictions 1 Introd...

Страница 23: ...attach SZX STAD1 a to a base Attach U SRP or U SRG2 to SZX STAD1 a Attaching U SRP Place the positioning pin cylinder type c on the back side of the base and rotate the centering knob d in clockwise...

Страница 24: ...1 Placing the notch a on the front side of the base secure the screws 2 pcs using the Allen wrench to attach SZX STAD1 b to a base Place the stage clamping knob c of BH2 SH horizontal knob stage on th...

Страница 25: ...AD mount for ILLT SZX2 STADM is necessary for using the SZX2 ILLTQ ILLTS LED transmitted light illumination base For details refer to the instruction manual for the SZX2 ILLTQ ILLTS LED Stage plate mo...

Страница 26: ...wipe the sliding surface on the cup stage and seat with a clean cloth Mount the stage plate Mount the specimen holder Clean the sliding surface periodically 1 2 3 4 TIP Before mounting remove dirt and...

Страница 27: ...to the specimen holder to fix the container by pinching TIP Do not touch the sliding surface on the cup stage and seat with a hand If the sliding surface are contaminated wash with a neutral detergent...

Страница 28: ...ributed by Manufactured by Shinjuku Monolith 2 3 1 Nishi Shinjuku Shinjuku ku Tokyo 163 0914 Japan www olympus global com REP EC AX6611 10 Issued in March 2019 Downloaded from ManualsNet com search en...

Отзывы: