E-7
After shooting, remove the inserted cam-
era and lens, then re-seal the empty
case and immerse it in tap water to
remove any salt as soon as possible.
6
Maintenance
For safe use of this product, always perform maintenance after each diving session.
For details, refer to “Handling After Shooting” and “Maintaining the Waterproof Function” in the PT-E series
case instruction manual. Apply the same procedures to this product.
Remove the O-rings from this product
using the provided pick for removing
O-rings. Take care not to damage the
O-rings.
If any foreign matter is attached to the
O-ring grooves, remove it using a
clean, lint-free cloth or cotton swab.
Also remove any foreign matter from
the O-ring contact surfaces and from
the port mount thread on the PT-E
series case.
After making sure that the PT-E series
case is completely dry, dismount this
product from the case.
Remove sand and dust from the O-rings.
Pinch each O-ring between your fingers
and lightly rub the entire circumference
to check for foreign matter, scratches
and cracks.
After removing foreign matter, apply the
provided grease to the O-rings and fit
them into the O-ring grooves.
To apply grease to each O-ring, squeeze
a drop of grease about the size of a
grain onto your finger and lightly rub the
entire circumference of the O-ring to
spread the grease thinly and evenly.