2
Safety precautions
General safety precautions
Observe the precautions described below when handling the instrument. The information is to be
supplemented by the dangers, warnings and cautions given in each chapter. Safety cannot be
guaranteed when the instrument is used in ways that are not specifically described.
DANGER
•
Never use this instrument for observation inside a human or animal cavity.
Otherwise, death of the person or animal may result.
•
Never use the instrument in the following types of environments.
•
Where flammable atmospheres are present
•
Where metal dust or other dust is present
Otherwise, an explosion or fire may result.
WARNING
•
Do not repair, disassemble, or modify the instrument.
This instrument does not contain any user serviceable parts. Do not disassemble, modify or
attempt to repair. User injury and/or equipment damage can result.
Contact Olympus for all repair and servicing.
•
Immediately stop using the instrument at the first sign of smoke, abnormal odor, abnormal noise,
or any other abnormality.
Even if operation of the instrument is still possible, turn off power.
•
Do not insert the insertion tube into an observation object that is in operation or conducting
electricity.
Otherwise the insertion tube may be damaged by being caught inside of the observation object,
etc., or the insertion tube may touch the object, resulting in electric shock.
•
Before stowing the instrument in its carrying case, be sure to turn off power and remove the
battery.
Leaving the battery loaded during storage can cause it to become hot, causing the risk of fire.
CAUTION
•
Do not use this instrument in any environment (including strongly radioactive environments) that
does not conform to the specified operating environment.
Otherwise, unexpected accidents that may damage the insertion tube may result.
•
Do not insert the insertion tube into an observation object in an environment that is outside the
operating temperature range.
A temperature alarm function will display a message whenever a temperature outside the
operating temperature range is approached.
If this happens, immediately remove the insertion tube from the observation object. Continued
use may damage or reduce the performance of the instrument.
•
Do not continue to use the instrument when it is wet with condensation.
Sudden temperatures changes such as those that occur when entering a warm room from the
outside cold can cause condensation to form inside the instrument. Using the instrument while it
is wet with condensation can cause malfunction. If condensation forms, leave the instrument in
the environment where it is to be used and allow the condensation to dry before using it.
•
Do not cover the main unit with a plastic bag or other object during use.
If the inside of the instrument cannot be cooled, the instrument damage may result.
•
Take care not to have your feet caught by a cord including the power cord or insertion tube.
Содержание IPLEX UltraLite