DMTA017-01EN, Rev. F, August 2016

Accessories and Spare Parts

 

43

6.3

Couplant-Feed Units

Couplant can be supplied to wedges by either an electric or a manual pump (see 
Table 8 on page 43).

U8775165

SNW2

8

31.75

23.5

U8775164

SNW3

8

31.75

65

Q7750014

SA17-DN

5

50

38

Q7750015

SA17-N

5

31.75

38

U8775056

SA27-DN and Creeping wave probe 
holder (U8775080)

5

40

23

a.

Standard yoke for TOFD-P/E probe mounting

b.

Standard yoke for phased array probe mounting

Table 8  Couplant

feed units 

Part number

Description

U8780008

Electric couplant-feed unit
3.78 l/min at 414 kPa (1 GPM at 60 psi) 
100 VAC/240 VAC

U8780009

Electric couplant-feed unit with suction capability
Same operating specification as CFU03

U8775153

4 L manual water pump with irrigation tubes and 
fittings

U8775001

8 L manual water pump with irrigation tubes and 
fittings

Table 7  Replacement yokes 

(continued)

Part 

number

Wedge compliance

Button 

OD 

(mm)

(mm)

(mm)

Содержание HSMT-Compact

Страница 1: ...nual This instruction manual contains essential information on how to use this Olympus product safely and effectively Before using this product thoroughly review this instruction manual Use the product as instructed Keep this instruction manual in a safe accessible location ...

Страница 2: ...ge to ensure the accuracy of the information contained therein and corresponds to the version of the product manufactured prior to the date appearing on the title page There could however be some differences between the manual and the product if the product was modified thereafter The information contained in this document is subject to change without notice Part number DMTA017 01EN Rev F August 2...

Страница 3: ...esence of Visual Interferences or Phantom Spots 5 Repair and Modification 5 Safety Symbols 5 Safety Signal Words 6 Note Signal Words 7 Safety 7 Warnings 8 Equipment Disposal 8 CE European Community 8 WEEE Directive 9 Warranty Information 9 Technical Support 10 Introduction 11 1 Overview 13 2 Scanner Assembly and Setup 19 2 1 Changing the Frame Configuration 19 2 2 Attaching the Umbilical Cable 23 ...

Страница 4: ...29 4 2 Replacing a Conventional Ultrasonic Probe 30 4 3 Replacing a Phased Array Probe 33 4 4 Unit Cleaning 35 5 Specifications 37 6 Accessories and Spare Parts 41 6 1 Umbilical Cables 41 6 2 Yokes 42 6 3 Couplant Feed Units 43 6 4 Connector Reference 44 6 5 Spare Parts 44 List of Figures 49 List of Tables 51 Index 53 ...

Страница 5: ...DMTA017 01EN Rev F August 2016 List of Abbreviations v List of Abbreviations hex hexagonal ID inside diameter PA phased array SLA spring loaded arm TOFD time of flight diffraction ...

Страница 6: ...DMTA017 01EN Rev F August 2016 List of Abbreviations vi ...

Страница 7: ...symbols are attached to the HSMT Compact scanner at the locations shown in Figure i 1 on page 1 and Figure i 2 on page 2 Label details are provided in Table 1 on page 2 If any or all of the labels or symbols are missing or illegible please contact Olympus Figure i 1 Identification label location Model number Serial number ...

Страница 8: ...ion of Conformity for details Contact your Olympus representative for more information The regulatory compliance mark RCM label indicates that the product complies with all applicable standards and has been registered with the Australian Communications and Media Authority ACMA for placement on the Australian market The WEEE symbol indicates that the product must not be disposed of as unsorted muni...

Страница 9: ...s Do not use the HSMT Compact scanner for any purpose other than its intended use It must never be used to inspect or examine human or animal body parts Instruction Manual This instruction manual contains essential information on how to use this Olympus product safely and effectively Before using this product thoroughly review this instruction manual Use the product as instructed Keep this instruc...

Страница 10: ...ipment malfunction and or damage or human injury Table 2 Ancillary equipment Equipment Description OmniScan PA and FOCUS Several types of phased array instrument model can be used may require one of the encoder cable adaptors listed below Phased array probe and wedge Several models used See Table 7 on page 42 for optional holder models required according to wedge models P N U8775201 Scanner interf...

Страница 11: ...tion The HSMT Compact scanner does not contain any user serviceable parts Opening the instrument might void the warranty In order to prevent human injury and or equipment damage do not disassemble modify or attempt to repair the instrument Safety Symbols The following safety symbols might appear on the instrument and in the instruction manual P N U8769010 0 3 m long adaptor LEMO female to Bendix m...

Страница 12: ...l shall be obeyed to avoid possible harm Safety Signal Words The following safety symbols might appear in the documentation of the instrument The DANGER signal word indicates an imminently hazardous situation It calls attention to a procedure practice or the like that if not correctly performed or adhered to will result in death or serious personal injury Do not proceed beyond a DANGER signal word...

Страница 13: ...gnal word calls attention to a note that provides important information or information essential to the completion of a task The NOTE signal word calls attention to an operating procedure practice or the like which requires special attention A note also denotes related parenthetical information that is useful but not imperative The TIP signal word calls attention to a type of note that helps you a...

Страница 14: ...trument Service instructions when applicable are for trained service personnel To avoid the risk of electric shock do not perform any work on the instrument unless qualified to do so For any problem or question regarding this instrument contact Olympus or an authorized Olympus representative Do not allow metallic or foreign objects to enter the device through connectors or any other openings Other...

Страница 15: ...arrier contact Olympus for assistance with the damage claim and equipment replacement if necessary This instruction manual explains the proper operation of your Olympus product The information contained herein is intended solely as a teaching aid and shall not be used in any particular application without independent testing and or verification by the operator or the supervisor Such independent ve...

Страница 16: ...ustomer service and product support If you experience any difficulties when using our product or if it fails to operate as described in the documentation first consult the user s manual and then if you are still in need of assistance contact our After Sales Service To locate the nearest service center visit the Service Centers page at http www olympus ims com ...

Страница 17: ...ect pipes of 4 in schedule or greater with minimum outside diameters of 114 mm or 4 5 in as well as flat surfaces To help users understand the HSMT Compact scanner s operation and configuration this manual provides the following subject matter The scanner s main components Assembly and setup Scanner operation Maintenance Technical specifications including system connectors Accessories and spare pa...

Страница 18: ...DMTA017 01EN Rev F August 2016 Introduction 12 ...

Страница 19: ... Compact scanner components The contents of a standard case are shown in Figure 1 1 on page 13 Figure 1 1 Case contents The main HSMT Compact scanner components are the frame with four wheels and two handles the probe holders the water couplant distribution system and the encoder see Figure 1 2 on page 14 ...

Страница 20: ...to move the unit across the surface being inspected If necessary the handles can be removed to reduce the height of the scanner Magnetic wheels The magnetic wheels help hold the unit against a ferromagnetic inspection surface The wheels are covered with a plastic layer for smooth motion during inspection see Figure 1 2 on page 14 Water manifold Handle for moving the scanner 2 Magnetic wheels Safet...

Страница 21: ...with water couplant Encoder A wheel encoder measures the scanner displacement to determine the position on the scan axis The encoder is waterproof and compatible with the OmniScan unit The encoder is also spring loaded to ensure that it remains in contact with the inspection surface with adequate pressure for different pipe diameters Safety attachment ring This ring can be used to secure the scann...

Страница 22: ... to help accurately position a probe holder The edges of the probe holder brackets can be used to position the exit points of the ST1 and ST2 TOFD wedges which are designed to align with each other see Figure 1 4 on page 17 Main water supply tube Safety attachment ring or umbilical bracket Encoder cable connection Water distribution to wedges Probe cables Wheel encoder ...

Страница 23: ...ation The frame can hold both conventional ultrasonic probes and phased array ultrasonic probes The frame section between the wheels can be changed to vary the scanner length see Figure 1 5 on page 17 Figure 1 5 Changing the scanner length Two removable rulers The edges on the probe holder brackets ...

Страница 24: ...see Figure 1 6 on page 18 Figure 1 6 Alternative scanner configuration Preamplifier If necessary a preamplifier often required for TOFD inspections can be mounted on the frame In the example shown in Figure 1 6 on page 18 an Olympus TRPP 5810 pulser preamplifier is used A bracket is required to mount the TRPP 5810 on HSMT scanners This bracket is included with some TRPP 5810 packages and can also ...

Страница 25: ...ssembly position can be adjusted on the frame it can be loosened and moved along the frame section As such the wheel assembly can be temporarily removed and then reinstalled so that the frame and the probe extend outside the limits of the wheels which is ideal for hard to reach areas such as pipe to component welds see Figure 1 6 on page 18 To change the frame section between the wheels 1 On the e...

Страница 26: ... Remove the cable from the encoder assembly b Remove the thumb screw that holds the encoder assembly and then pull this assembly away from the scanner see Figure 2 2 on page 20 The remaining frame screws are now easy to access Figure 2 2 Thumb screw for the encoder assembly Frame section Wheel assembly Encoder assembly Thumb screw ...

Страница 27: ...emoval of the frame screws behind the encoder assembly 4 Reinstall the new frame section and scanner parts in the reverse order from the preceding steps To adjust the wheel assembly position on the frame 1 Using a hexagonal key loosen the two screws that hold the wheel assembly onto the frame section see Figure 2 4 on page 21 Figure 2 4 Loosening the wheel assembly Frame section Wheel assembly ...

Страница 28: ...to the frame If necessary you can temporarily remove the entire wheel assembly and probe holders from the frame section in order to reassemble them in the desired new configuration 3 Attach the remaining scanner components in the desired configuration An example inspection setup with the frame extended beyond the wheel limits is shown in Figure 2 6 on page 23 NOTE ...

Страница 29: ...ner Assembly and Setup 23 Figure 2 6 Scanner with frame extended beyond wheel limits 2 2 Attaching the Umbilical Cable The umbilical cable can be attached to the HSMT Compact scanner using the umbilical bracket see Figure 2 7 on page 24 ...

Страница 30: ...bracket slide the mounting hole over the attachment on the HSMT Compact scanner and then release the pin see Figure 2 8 on page 24 Figure 2 8 AEIX378 umbilical cable attachment 2 Loosen the strap wrap it around the umbilical cable then reinsert the strap into the buckle and tighten it see Figure 2 9 on page 25 Attachment Umbilical bracket Locking pin Mounting hole ...

Страница 31: ...er 1 Connect the probes and any other equipment a preamplifier for example to the acquisition unit 2 Connect the encoder cable to the side of the scanner carefully align the marks on the connector and then connect the other end of the encoder cable to the instrument see Figure 2 10 on page 25 Figure 2 10 Scanner connections Water manifold intake Encoder connector Short section of tube between the ...

Страница 32: ...screw that secures the probe holder bracket to the scanner frame see Figure 2 11 on page 26 Figure 2 11 Adjusting the probe position b Slide the probe holder to the desired position and then tighten the thumb screw For the TOFD ST1 and ST2 models exclusively the edges of the probe holder brackets are in line with the beam exit point of the wedge to facilitate probe positioning Equipment connection...

Страница 33: ...ction surface and then align the scanner so that the inspection area is centered between the probes 2 With the inspection area centered between the probes bring the scanner s magnetic wheels into contact with the inspection surface 3 Next push or pull the scanner in the desired inspection direction If the inspection surface is made of a ferromagnetic material the scanner does not need to be pushed...

Страница 34: ...DMTA017 01EN Rev F August 2016 Chapter 3 28 ...

Страница 35: ... conditions the HSMT Compact scanner parts might need periodic cleaning 4 1 Replacing Wheels This section contains the procedure for changing the wheels once they are too worn To avoid injury use caution when handling the magnetic wheels the magnetic pull of the wheels is strong and could cause bodily harm for example a finger pinched between two wheels or between a wheel and a steel surface To re...

Страница 36: ...he correct position 4 Repeat the procedure for the other wheels To avoid the risk of injury from magnetic attraction forces between wheels only remove and replace one wheel at a time always reinstall the magnetic wheel on the scanner before removing the next one 4 2 Replacing a Conventional Ultrasonic Probe This section describes the procedure for removing a conventional ultrasonic probe and wedge...

Страница 37: ...cable 4 Remove the scanner from the inspection surface 5 Using a flathead screwdriver loosen the screw at the back of the spring loaded arm SLA just enough to free the yoke from the arm see Figure 4 2 on page 31 Figure 4 2 The screw that secures the yoke to the SLA 6 Remove the yoke 7 Using a hex socket head screwdriver remove the screw on the side of the yoke that holds the parts together see Fig...

Страница 38: ...mbly 8 Ensure that the probe cable is disconnected and then unscrew the probe from the wedge see Figure 4 4 on page 32 In certain equipment configurations it may be possible to unscrew the probe without removing the wedge from the yoke and the yoke from the SLA Figure 4 4 Unscrewing the probe ...

Страница 39: ...the procedure for replacing a conventional ultrasonic probe 4 3 Replacing a Phased Array Probe This section describes the procedures for removing a phased array ultrasonic probe from the scanner and for removing the probe and wedge from the holder To replace a phased array probe 1 Turn off the couplant flow 2 Disconnect the couplant tubes from the couplant source 3 Disconnect the probe cable from ...

Страница 40: ...older and probe assembly from the scanner 7 Using a hexagonal key remove the screw on the side of the yoke that holds the parts together see Figure 4 5 on page 34 Figure 4 5 The screw that secures the yoke assembly 8 Using a cross head screwdriver loosen the four screws see Figure 4 6 on page 34 and then remove the probe from the wedge Figure 4 6 The probe holder 9 Install the new probe ...

Страница 41: ...or replacing a phased array probe 4 4 Unit Cleaning The HSMT Compact scanner s external surfaces can be cleaned when needed The magnetic wheels can be strongly attracted to any ferromagnetic materials or surfaces which potentially can cause injuries for example pinched fingers or equipment damage To clean the unit 1 Ensure the unit is turned off by removing the source of power 2 Disconnect all cab...

Страница 42: ...DMTA017 01EN Rev F August 2016 Chapter 4 36 5 Wait until the unit dries completely before reconnecting the cables ...

Страница 43: ...e Table 3 General specifications Parameter Value Dimensions See Table 4 on page 38 and Figure 5 2 on page 38 Encoder Type Quadrature Resolution 12 steps mm 0 15 steps mm encoder calibration is recommended for every setup Waterproof Pinout See Figure 5 1 on page 37 Power rating 5 VDC 25 mA max Frequency 0 kHz to 1 5 kHz for a maximum displacement velocity per second of 10 cm or 4 in Case White Gree...

Страница 44: ... overall Bar length mm Width Length Height mm in mm in mm in 250 152 5 98 344 13 54 102 4 02 450 152 5 98 544 21 42 102 4 02 650 152 5 98 744 29 29 102 4 02 Table 5 Environmental conditions Parameter Value Operating temperature 10 C to 55 C Storage temperature 30 C to 60 C Length Width Height ...

Страница 45: ...pecifications 39 Relative humidity RH Max 85 RH noncondensing Altitude Up to 2000 m Outdoor use Yes Wet locations Yes IP rating Waterproof designed for IP67 Pollution level 1 Table 5 Environmental conditions continued Parameter Value ...

Страница 46: ...DMTA017 01EN Rev F August 2016 Chapter 5 40 ...

Страница 47: ... without the need of connection boxes for order details see Table 6 on page 41 Table 6 Umbilical cables divisible conduit type Part Number Description U8779093 One 0 3 m divisible cable conduit with a 16 mm ID Well suited to 2 PA irrigation tube and the encoder cable U8779094 One 0 3 m divisible cable conduit with a 19 2 mm ID Well suited to 2 PA 2 conventional UT irrigation tube and the encoder c...

Страница 48: ...m B mm Standard yokes U8775048a ST1 ST2 SPE1 SPE2 SPE3 SA0 5 31 75 23 5 U8775047b SA1 SA2 SA10 SA11 SA12 SA31 SA32 SI1 SPWZ3 SNW1 AQ25 WR and SNW3 AQ25 8 40 55 U8775046 SA10 SA11 SA31 and SA32 8 40 38 Other yokes U8775187 SPWZ1 and SA14 in reverse position 8 40 46 U8780194 SPWZ1 SA14 RexoFORM and SNW3 AQ25 WR 8 40 65 U8775055 SA1 L lateral 8 45 60 U8779096 SA3 8 50 55 U8775084 SA4 SA5 and HydroFOR...

Страница 49: ...a Standard yoke for TOFD P E probe mounting b Standard yoke for phased array probe mounting Table 8 Couplant feed units Part number Description U8780008 Electric couplant feed unit 3 78 l min at 414 kPa 1 GPM at 60 psi 100 VAC 240 VAC U8780009 Electric couplant feed unit with suction capability Same operating specification as CFU03 U8775153 4 L manual water pump with irrigation tubes and fittings ...

Страница 50: ...instrument an optional adaptor is required see Table 9 on page 44 6 5 Spare Parts An exploded view of the scanner is shown in Figure 6 2 on page 45 A list of standard spare parts is provided in Table 10 on page 45 Table 9 Required encoder cable adaptor Scanner Connector Instrument OmniScan MX OmniScan MX2 SX and FOCUS PX TomoScan FOCUS LT LEMO from July 2013 onward P N U8780329 P N U8769010 DE15 P...

Страница 51: ...em Qtya Part number Description 1b 1 U8775097 Spring loaded encoder and bracket 2 1 U8775235 M5 25 mm hex flat 3 4 U8908261 M3 16 mm hex socket 4 4 U8905961 Spring washer M3 5 1 Q8300237 Thumb screw assembly 10 mm 6 4 U8902678 10 32 to T 1 8 in ID short barb brass fitting 7 8 U8900310 Dovetail M5 nut 8 2 Q8300422 Ruler ...

Страница 52: ...numbers below 872542 nn U8775204 90 probe holder bracket for serial numbers 872542 nn and above 20 4 U8775070 Thumb screw assembly 12 mm 21 4 U8775041 Shoulder screw for yoke 22 8 U8775110 Yoke bearing 23 4 U8830739 Spring loaded arm SLA 24 8 U8900337 Spring for SLA 25 16 Q8300929 M2 5 6 mm hex socket 26 2 U8775047 PA yoke 5 40 mm wide 55 mm long U8775046 PA yoke 5 40 mm wide 38 mm long 27 4 U8775...

Страница 53: ...l bracket Not Shown 1 U8775313 5 m encoder cable with LEMO connector for direct connection to OmniScan MX2 and SX models Not Shown 1 U8775040 Metric hexagonal key kit Not Shown 5 U8902320 4 mm ID irrigation tube unit ft Not Shown 4 U8900341 0 125 in ID irrigation tube unit ft Not Shown 1 U8902317 Irrigation valve Not Shown 4 U8902321 Y irrigation splitter Not Shown 1 Q8300932 Velcro tape unit ft a...

Страница 54: ...DMTA017 01EN Rev F August 2016 Chapter 6 48 ...

Страница 55: ...ly 21 Figure 2 5 Sliding the wheel assembly onto the frame 22 Figure 2 6 Scanner with frame extended beyond wheel limits 23 Figure 2 7 Umbilical cable attachment and bracket 24 Figure 2 8 AEIX378 umbilical cable attachment 24 Figure 2 9 Loosened strap left and tightened strap right 25 Figure 2 10 Scanner connections 25 Figure 2 11 Adjusting the probe position 26 Figure 4 1 Removing the wheel screw...

Страница 56: ...DMTA017 01EN Rev F August 2016 List of Figures 50 ...

Страница 57: ... 2 Ancillary equipment 4 Table 3 General specifications 37 Table 4 Dimensions overall 38 Table 5 Environmental conditions 38 Table 6 Umbilical cables divisible conduit type 41 Table 7 Replacement yokes 42 Table 8 Couplant feed units 43 Table 9 Required encoder cable adaptor 44 Table 10 Spare parts 45 ...

Страница 58: ...DMTA017 01EN Rev F August 2016 List of Tables 52 ...

Страница 59: ... encoder 15 frame 14 overview 13 positioning rulers 16 preamplifier 18 safety attachment ring 15 water manifold 15 wheels 14 configuration frame 17 19 connector reference specifications 44 D DANGER signal word 6 dimensions scanner 37 direct current symbol 2 disposal equipment 8 E encoder 15 37 equipment disposal 8 European Community CE 8 exploded view scanner 44 F frame configuration changing 17 1...

Страница 60: ... replacing a conventional ultrasonic probe 30 replacing a phased array probe 33 replacing wheels 29 scanner operation 27 setting up the scanner 25 pumps 43 purpose manual 11 R rating label location 2 RCM mark 2 repair instrument 5 replacement conventional ultrasonic probe 30 phased array probe 33 wheels 29 ring safety attachment 15 ruler probe position 16 S safety instrument compatibility 4 misuse...

Страница 61: ...rd 6 warning symbols general 6 shock hazard 6 warnings general 8 magnetic wheels 15 29 30 35 misuse of instrument 3 warranty information 9 waste electrical and electronic equipment 9 water manifold 15 WEEE directive 9 symbol 2 wheels 14 replacement 29 safety magnetic wheels 15 29 30 35 Y yokes 42 ...

Страница 62: ...DMTA017 01EN Rev F August 2016 Index 56 ...

Отзывы: